Open general

Footprint: thermal pad soldered and IPC pads; TI DRV0006B land has no EP (accuracy is specified unsoldered)

noah ·

Footprint: the page solders the thermal pad; TI specifies TMP117 accuracy with it unsoldered, and its land differs

The page's footprint is KiCad's WSON-6-1EP_2x2mm_P0.65mm_EP1x1.6mm: pads 0.375 x 0.4 mm at +-0.8875 mm and a soldered 1 x 1.6 mm thermal land with paste.

TI TMP117 data sheet SNOSD82D:

  • Electrical characteristics: the +-0.1 C accuracy (DRV) is specified with the thermal pad unsoldered.
  • Section 9/10.1: "The package thermal pad ... should be left unsoldered for best measurement accuracy"; "To achieve a high precision temperature reading for a rigid PCB, do not solder down the thermal pad." (Soldering is for flexible PCBs.)
  • DRV0006B example board layout, p. 41: six pads 0.45 x 0.30 mm at a 1.95 mm span, 0.65 mm pitch, R0.05, and no thermal pad land. Stencil p. 42 is the same openings.

Suggested fix: TI's DRV0006B land (six 0.45 x 0.30 pads at +-0.975 mm, no EP land), or offer both variants and make the unsoldered one the default. Found with adom-aiflow part-check (adom-aiflow 0.2.93), 2026-11-20.