component
TMCMB1A107MTR2F
Public Made by Adomby adom
Vishay Intertech Tantalum Capacitors, CASE-B-3528-21(mm). Polarised capacitor: pin 1 is + by the KiCad polarised-footprint convention, KiCad symbol/footprint/3D.
← Commit history
tmcmb1a107mtr2f: specified limits as data (metadata.characteristics, 29 rows from the datasheet)
2 files changed
+392−1
README.md+36@@ -20,6 +20,42 @@ TMCMB1A107MTR2F from Vishay Intertech, in a CASE-B-3528-21(mm). Pinout and pin d | Category | Capacitors | | Pins | 2 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Capacitance tolerance | | -20 | | 20 | % | M code = ±20 % | 1 |+| Capacitance change at -55 °C | | -10 | | 0 | % | Temperature characteristics, vs initial value, at -55 °C | 8 |+| Capacitance change at +85 °C | | 0 | | 10 | % | Temperature characteristics, vs initial value, at +85 °C | 8 |+| Capacitance change at +125 °C | | 0 | | 12 | % | Temperature characteristics, vs initial value, at +125 °C | 8 |+| Maximum DC leakage current | DCL | | | 20 | µA | MAX. DCL at +25 °C | 5 |+| Maximum dissipation factor | DF | | | 30 | % | MAX. DF at +25 °C, 120 Hz | 5 |+| Maximum ESR | ESR | | | 1.7 | Ω | MAX. ESR at +25 °C, 100 kHz | 5 |+| Maximum ripple current | IRMS | | | 0.238 | A | MAX. ripple, 100 kHz IRMS | 5 |+| Dissipation factor at -55 °C | DF | | | 60 | % | Temperature characteristics, 30 % initial spec, at -55 °C | 8 |+| Dissipation factor at +85 °C | DF | | | 30 | % | Temperature characteristics, 30 % initial spec, at +85 °C | 8 |+| Dissipation factor at +125 °C | DF | | | 40 | % | Temperature characteristics, 30 % initial spec, at +125 °C | 8 |+| Leakage current at +85 °C | | | | 1000 | % | Temperature characteristics, % of specified initial value, at +85 °C | 8 |+| Leakage current at +125 °C | | | | 1250 | % | Temperature characteristics, % of specified initial value, at +125 °C | 8 |+| Rated voltage at +85 °C | | | | 10 | V | DC rating at +85 °C (1A code) | 5 |+| Rated voltage at +125 °C | | | | 6.3 | V | DC rating at +125 °C (1A code) | 5 |+| Maximum permissible power dissipation | | | | 0.096 | W | Case B, at +25 °C in free air | 8 |+| Operating temperature | | -55 | | 125 | °C | Above 85 °C, voltage derating required | 1 |+| Recommended operating voltage | | | | 5 | V | Derating guideline below +85 °C, 10 V rating | 7 |+| Maximum reverse voltage at 25 °C | | | | 1 | V | At 25 °C; or 10 % of rated voltage, whichever is smaller | 14 |+| Maximum reverse voltage at 85 °C | | | | 0.5 | V | At 85 °C; or 5 % of rated voltage, whichever is smaller | 14 |+| Capacitance change after solder heat | | -5 | | 5 | % | Solder dip 260 °C, B case 10 s; or reflow 260 °C 10 s | 8 |+| Capacitance change after moisture resistance (no load) | | -10 | | 10 | % | 40 °C, 90-95 % RH, 500 h, no load | 8 |+| Capacitance change after high temperature load | | -10 | | 10 | % | 85 °C, rated voltage, 2000 h | 8 |+| Leakage current after high temperature load | | | | 125 | % | 85 °C, rated voltage, 2000 h; % of initial specified value | 8 |+| Capacitance change after thermal shock | | -10 | | 10 | % | -55 °C to 125 °C, 5 cycles | 8 |+| Capacitance change after moisture resistance load | | -10 | | 10 | % | 40 °C, 90-95 % RH, rated voltage, 500 h | 8 |+| Dissipation factor after moisture resistance load | DF | | | 150 | % | 40 °C, 90-95 % RH, rated voltage, 500 h; % of initial specified value | 8 |+| Leakage current after moisture resistance load | | | | 200 | % | 40 °C, 90-95 % RH, rated voltage, 500 h; % of initial specified value | 8 |+| Failure rate | | | | 1 | %/1000 h | 85 °C, rated voltage via 1 Ω/V protective resistor | 8 |+ ## CAD (KiCad official) - Symbol: `TMCMB1A107MTR2F`
page.json+356−1@@ -142,6 +142,361 @@ "Package": "CASE-B-3528-21(mm)", "Category": "Capacitors", "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "90cef729befdadb5",+ "rows": [+ {+ "name": "Capacitance tolerance",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -20,+ "typ": null,+ "max": 20,+ "conditions": "M code = ±20 %",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Capacitance change at -55 °C",+ "symbol": "",+ "kind": "temperature_coefficient",+ "unit": "%",+ "min": -10,+ "typ": null,+ "max": 0,+ "conditions": "Temperature characteristics, vs initial value, at -55 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Capacitance change at +85 °C",+ "symbol": "",+ "kind": "temperature_coefficient",+ "unit": "%",+ "min": 0,+ "typ": null,+ "max": 10,+ "conditions": "Temperature characteristics, vs initial value, at +85 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Capacitance change at +125 °C",+ "symbol": "",+ "kind": "temperature_coefficient",+ "unit": "%",+ "min": 0,+ "typ": null,+ "max": 12,+ "conditions": "Temperature characteristics, vs initial value, at +125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Maximum DC leakage current",+ "symbol": "DCL",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "MAX. DCL at +25 °C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum dissipation factor",+ "symbol": "DF",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "MAX. DF at +25 °C, 120 Hz",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum ESR",+ "symbol": "ESR",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 1.7,+ "conditions": "MAX. ESR at +25 °C, 100 kHz",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum ripple current",+ "symbol": "IRMS",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.238,+ "conditions": "MAX. ripple, 100 kHz IRMS",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Dissipation factor at -55 °C",+ "symbol": "DF",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "Temperature characteristics, 30 % initial spec, at -55 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Dissipation factor at +85 °C",+ "symbol": "DF",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "Temperature characteristics, 30 % initial spec, at +85 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Dissipation factor at +125 °C",+ "symbol": "DF",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "Temperature characteristics, 30 % initial spec, at +125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Leakage current at +85 °C",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 1000,+ "conditions": "Temperature characteristics, % of specified initial value, at +85 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Leakage current at +125 °C",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 1250,+ "conditions": "Temperature characteristics, % of specified initial value, at +125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Rated voltage at +85 °C",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "DC rating at +85 °C (1A code)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Rated voltage at +125 °C",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 6.3,+ "conditions": "DC rating at +125 °C (1A code)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum permissible power dissipation",+ "symbol": "",+ "kind": "thermal",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 0.096,+ "conditions": "Case B, at +25 °C in free air",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 125,+ "conditions": "Above 85 °C, voltage derating required",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended operating voltage",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 5,+ "conditions": "Derating guideline below +85 °C, 10 V rating",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Maximum reverse voltage at 25 °C",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "At 25 °C; or 10 % of rated voltage, whichever is smaller",+ "source_page": 14,+ "source": "datasheet"+ },+ {+ "name": "Maximum reverse voltage at 85 °C",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.5,+ "conditions": "At 85 °C; or 5 % of rated voltage, whichever is smaller",+ "source_page": 14,+ "source": "datasheet"+ },+ {+ "name": "Capacitance change after solder heat",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "Solder dip 260 °C, B case 10 s; or reflow 260 °C 10 s",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Capacitance change after moisture resistance (no load)",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -10,+ "typ": null,+ "max": 10,+ "conditions": "40 °C, 90-95 % RH, 500 h, no load",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Capacitance change after high temperature load",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -10,+ "typ": null,+ "max": 10,+ "conditions": "85 °C, rated voltage, 2000 h",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Leakage current after high temperature load",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "85 °C, rated voltage, 2000 h; % of initial specified value",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Capacitance change after thermal shock",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -10,+ "typ": null,+ "max": 10,+ "conditions": "-55 °C to 125 °C, 5 cycles",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Capacitance change after moisture resistance load",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -10,+ "typ": null,+ "max": 10,+ "conditions": "40 °C, 90-95 % RH, rated voltage, 500 h",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Dissipation factor after moisture resistance load",+ "symbol": "DF",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "40 °C, 90-95 % RH, rated voltage, 500 h; % of initial specified value",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Leakage current after moisture resistance load",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 200,+ "conditions": "40 °C, 90-95 % RH, rated voltage, 500 h; % of initial specified value",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Failure rate",+ "symbol": "",+ "kind": "electrical",+ "unit": "%/1000 h",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "85 °C, rated voltage via 1 Ω/V protective resistor",+ "source_page": 8,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -184,4 +539,4 @@ "visibility": { "public": true }-}+}