page.json+6−3
@@ -38,13 +38,13 @@         "number": "2",         "name": "RESET",         "type": "output",-        "description": "Active-low open-drain RESET output. Driven low when VDD falls below the negative-going threshold VIT- (2.93 V for TLV803S) and remains low for the delay time td (200 ms typ) after VDD exceeds VIT-. Requires a 10 k\u03a9 to 1 M\u03a9 external pull-up; pull-up voltage is not limited to VDD."+        "description": "Active-low open-drain RESET output. Driven low when VDD falls below the negative-going threshold VIT- (2.93 V for TLV803S) and remains low for the delay time td (200 ms typ) after VDD exceeds VIT-. Requires a 10 kΩ to 1 MΩ external pull-up; pull-up voltage is not limited to VDD."       },       {         "number": "3",         "name": "VDD",         "type": "power_in",-        "description": "Supply voltage input. Recommended operating range 1.1 V to 6 V; absolute maximum 7 V. Place a 0.1 \u00b5F ceramic bypass capacitor close to this pin. Supply current IDD \u2248 9 \u00b5A typ."+        "description": "Supply voltage input. Recommended operating range 1.1 V to 6 V; absolute maximum 7 V. Place a 0.1 µF ceramic bypass capacitor close to this pin. Supply current IDD ≈ 9 µA typ."       }     ],     "provenance": {@@ -108,5 +108,8 @@     "docs/tlv803sdbzr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file