← Commit history
page.json+6−3@@ -58,13 +58,13 @@ "number": "2", "name": "RESET", "type": "output",- "description": "Open-drain active-low reset output; driven low when VDD falls below VIT- (2.93 V for this variant) and remains asserted for the reset delay period tD (400 ms typ) after VDD rises above VIT+; maximum sink current 5 mA, VOL \u2264 300 mV at 2 mA sink with VDD = 3.3 V; open-drain leakage Ilkg(OD) \u2264 350 nA at VDD = VPULLUP = 6 V; requires external pull-up resistor up to 6.5 V."+ "description": "Open-drain active-low reset output; driven low when VDD falls below VIT- (2.93 V for this variant) and remains asserted for the reset delay period tD (400 ms typ) after VDD rises above VIT+; maximum sink current 5 mA, VOL ≤ 300 mV at 2 mA sink with VDD = 3.3 V; open-drain leakage Ilkg(OD) ≤ 350 nA at VDD = VPULLUP = 6 V; requires external pull-up resistor up to 6.5 V." }, { "number": "3", "name": "VDD", "type": "power_in",- "description": "Input supply voltage (1.7 V to 6 V operating, abs max 6.5 V); monitored by the internal comparator against the fixed threshold VIT- = 2.93 V; IDD = 250 nA typ / 1 \u00b5A max at 3.3 V; a 0.1 \u00b5F to 1 \u00b5F bypass capacitor is recommended."+ "description": "Input supply voltage (1.7 V to 6 V operating, abs max 6.5 V); monitored by the internal comparator against the fixed threshold VIT- = 2.93 V; IDD = 250 nA typ / 1 µA max at 3.3 V; a 0.1 µF to 1 µF bypass capacitor is recommended." } ], "provenance": {@@ -142,5 +142,8 @@ "docs/tlv803ef29dbzr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }