← Commit history
page.json+6−3@@ -32,7 +32,7 @@ "number": "1", "name": "RESET", "type": "output",- "description": "Active-low, open-drain reset output. Driven low when VDD falls below the negative threshold VIT- (~2.63 V for the -26 option) and remains asserted for the reset time delay tD (~200 ms for the -A option) after VDD rises above VIT+. Requires an external pull-up resistor (typ. 10 k\u03a9) to VDD or another rail up to 6 V because this is the TLV803E open-drain variant."+ "description": "Active-low, open-drain reset output. Driven low when VDD falls below the negative threshold VIT- (~2.63 V for the -26 option) and remains asserted for the reset time delay tD (~200 ms for the -A option) after VDD rises above VIT+. Requires an external pull-up resistor (typ. 10 kΩ) to VDD or another rail up to 6 V because this is the TLV803E open-drain variant." }, { "number": "2",@@ -44,7 +44,7 @@ "number": "3", "name": "VDD", "type": "power_in",- "description": "Input supply voltage and monitored rail. Recommended operating range 1.7 V to 6 V (absolute max 6.5 V). Typical supply current IDD = 250 nA at VDD = 3.3 V; 0.4 \u03bcA typical at 6 V."+ "description": "Input supply voltage and monitored rail. Recommended operating range 1.7 V to 6 V (absolute max 6.5 V). Typical supply current IDD = 250 nA at VDD = 3.3 V; 0.4 μA typical at 6 V." } ], "provenance": {@@ -130,5 +130,8 @@ "docs/tlv803ea26rdbzr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }