← Commit history
package.json+508−4@@ -1,6 +1,6 @@ { "slug": "tlv431aqfta",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Diodes Incorporated Voltage Reference, SOT-23. Datasheet-verified pinout, KiCad symbol/footprint/3D.", "tags": [@@ -24,6 +24,510 @@ "docs/hero.png", "docs/tlv431aqfta-datasheet.pdf", "viewers/symbol.html",- "viewers/footprint.html"- ]-}+ "viewers/footprint.html",+ "tlv431aqfta-etched.step",+ "tlv431aqfta-etched.glb"+ ],+ "component": {+ "mpn": "TLV431AQFTA",+ "manufacturer": "Diodes Incorporated",+ "package": "SOT-23",+ "pin_count": 3,+ "category": "Voltage Reference",+ "parts": {+ "symbol": "tlv431aqfta.kicad_sym",+ "footprint": "tlv431aqfta.kicad_mod",+ "model_3d": "tlv431aqfta-etched.glb",+ "model_3d_plain": "tlv431aqfta.glb",+ "model_3d_step": "tlv431aqfta-etched.step",+ "model_3d_step_plain": "tlv431aqfta.step",+ "lbr": "tlv431aqfta.lbr"+ },+ "pins": [+ {+ "number": "1",+ "name": "REF",+ "type": "input",+ "description": "Reference / feedback input. Internal error amplifier compares this pin to the 1.24V bandgap reference and modulates cathode current to force VREF across the external divider tap. Typical IREF = 0.15µA (0.5µA max) at 25°C; absolute-max input current range -0.05 to 3mA."+ },+ {+ "number": "2",+ "name": "CATHODE",+ "type": "power_in",+ "description": "Cathode (K) - the shunt terminal that sinks current to regulate. Absolute-max VKA = 20V, IKA = ±20mA continuous; recommended operating VKA from VREF to 18V, IKA from 0.1mA to 15mA. Minimum cathode current for regulation is ~55µA typical (80µA max at 25°C)."+ },+ {+ "number": "3",+ "name": "ANODE",+ "type": "power_in",+ "description": "Anode (A) - the ground-side / return terminal for the shunt regulator. All internal references and the cathode current return through this pin."+ }+ ],+ "provenance": {+ "rebuilt": "component block rebuilt 2026-10-05 from this page's own README pinout table and .kicad_sym (pins cross-checked), no re-extraction",+ "cad": "KiCad official (CC-BY-SA 4.0)",+ "cad_basis": {+ "from": [+ "README CAD section (factory cad_wording)",+ ".kicad_mod model path agrees"+ ],+ "missing": []+ }+ },+ "viewers": {+ "symbol": "viewers/symbol.html",+ "footprint": "viewers/footprint.html"+ },+ "distributor_links": {+ "lcsc": "C460757",+ "digikey": "TLV431AQFTADITR-ND",+ "mouser": "621-TLV431AQFTA"+ },+ "distributor_check": {+ "checked_at": "2026-10-05T19:21:08Z",+ "source": "Component Ocean /api/assign-pns + lcsc_map",+ "digikey": {+ "pn": "TLV431AQFTADITR-ND",+ "status": "found"+ },+ "mouser": {+ "pn": "621-TLV431AQFTA",+ "status": "found"+ }+ },+ "models_3d": [+ {+ "file": "tlv431aqfta.step",+ "role": "plain",+ "up": "Z",+ "units": "mm",+ "origin": "footprint origin = pad-pattern centre",+ "seat": "z = 0",+ "extents_mm": [+ 2.5,+ 3,+ 1.2+ ],+ "zmin_mm": 0,+ "centre_offset_mm": 0,+ "footprint_binding": "identity",+ "sha256": "dd5d1711204e1d8d26cd11490923bd84340820baa69538c385a4300ec2539bc0",+ "checked": "2026-10-07",+ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"+ },+ {+ "file": "tlv431aqfta-etched.step",+ "role": "eda",+ "up": "Z",+ "units": "mm",+ "origin": "footprint origin = pad-pattern centre",+ "seat": "z = 0",+ "extents_mm": [+ 2.5,+ 3,+ 1.2+ ],+ "zmin_mm": 0,+ "centre_offset_mm": 0,+ "footprint_binding": "identity",+ "sha256": "bb1551771541af9851804d7195b56d81dc8de77017f155b629a16145f0aef252",+ "checked": "2026-10-07",+ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"+ }+ ]+ },+ "metadata": {+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": null,+ "rows": [+ {+ "name": "Cathode Voltage (recommended)",+ "symbol": "VKA",+ "kind": "recommended_operating",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 18,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Cathode Current (recommended)",+ "symbol": "IKA",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": 0.1,+ "typ": null,+ "max": 15,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Ambient Temperature Range",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Cathode Voltage",+ "symbol": "VKA",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Continuous Cathode Current",+ "symbol": "IKA",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -20,+ "typ": null,+ "max": 20,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reference Input Current Range",+ "symbol": "IREF",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -0.05,+ "typ": null,+ "max": 3,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Input Supply Voltage (relative to ground)",+ "symbol": "VIN",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.03,+ "typ": null,+ "max": 18,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Junction Temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature",+ "symbol": "TS",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "ESD Human Body Model",+ "symbol": "HBM",+ "kind": "absolute_maximum",+ "unit": "kV",+ "min": null,+ "typ": null,+ "max": 4,+ "conditions": "Human Body Model",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "ESD Machine Model",+ "symbol": "MM",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 400,+ "conditions": "Machine Model",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "ESD Charged Device Model",+ "symbol": "CDM",+ "kind": "absolute_maximum",+ "unit": "kV",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "Charged Device Model",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power Dissipation (SOT23)",+ "symbol": "PDIS",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 330,+ "conditions": "TA = +25°C, TJ = +150°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-Ambient Thermal Resistance (SOT23)",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 380,+ "max": null,+ "conditions": "SOT23 package",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reference Voltage (TLV431AQ, TA=+25°C)",+ "symbol": "VREF",+ "kind": "electrical",+ "unit": "V",+ "min": 1.228,+ "typ": 1.24,+ "max": 1.252,+ "conditions": "VKA = VREF, TA = +25°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Reference Voltage (TLV431AQ, 0 to +70°C)",+ "symbol": "VREF",+ "kind": "electrical",+ "unit": "V",+ "min": 1.221,+ "typ": null,+ "max": 1.259,+ "conditions": "VKA = VREF, TA = 0°C to +70°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Reference Voltage (TLV431AQ, -40 to +85°C)",+ "symbol": "VREF",+ "kind": "electrical",+ "unit": "V",+ "min": 1.215,+ "typ": null,+ "max": 1.265,+ "conditions": "VKA = VREF, TA = -40°C to +85°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Reference Voltage (TLV431AQ, -40 to +125°C)",+ "symbol": "VREF",+ "kind": "electrical",+ "unit": "V",+ "min": 1.209,+ "typ": null,+ "max": 1.271,+ "conditions": "VKA = VREF, TA = -40°C to +125°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Deviation of Reference Voltage Over Full Temperature Range (0 to +70°C)",+ "symbol": "VREF(DEV)",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 4,+ "max": 12,+ "conditions": "VKA = VREF, TA = 0°C to +70°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Deviation of Reference Voltage Over Full Temperature Range (-40 to +85°C)",+ "symbol": "VREF(DEV)",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 6,+ "max": 20,+ "conditions": "VKA = VREF, TA = -40°C to +85°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Deviation of Reference Voltage Over Full Temperature Range (-40 to +125°C)",+ "symbol": "VREF(DEV)",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 11,+ "max": 31,+ "conditions": "VKA = VREF, TA = -40°C to +125°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Ratio of Change in Reference Voltage to Change in Cathode Voltage (6 V)",+ "symbol": "ΔVREF/ΔVKA",+ "kind": "electrical",+ "unit": "mV/V",+ "min": null,+ "typ": -1.5,+ "max": -2.7,+ "conditions": "VKA for VREF to 6V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Ratio of Change in Reference Voltage to Change in Cathode Voltage (18 V)",+ "symbol": "ΔVREF/ΔVKA",+ "kind": "electrical",+ "unit": "mV/V",+ "min": null,+ "typ": -1.5,+ "max": -2.7,+ "conditions": "VKA for VREF to 18V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Reference Input Current",+ "symbol": "IREF",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.15,+ "max": 0.5,+ "conditions": "R1 = 10kΩ, R2 = OC",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "IREF Deviation Over Full Temperature Range (0 to +70°C)",+ "symbol": "IREF(DEV)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.05,+ "max": 0.3,+ "conditions": "R1 = 10kΩ, R2 = OC, TA = 0°C to +70°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "IREF Deviation Over Full Temperature Range (-40 to +85°C)",+ "symbol": "IREF(DEV)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.1,+ "max": 0.4,+ "conditions": "R1 = 10kΩ, R2 = OC, TA = -40°C to +85°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "IREF Deviation Over Full Temperature Range (-40 to +125°C)",+ "symbol": "IREF(DEV)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.15,+ "max": 0.5,+ "conditions": "R1 = 10kΩ, R2 = OC, TA = -40°C to +125°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Minimum Cathode Current for Regulation (0 to +70°C)",+ "symbol": "IKMIN",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 55,+ "max": 80,+ "conditions": "VKA = VREF, TA = 0°C to +70°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Minimum Cathode Current for Regulation (-40 to +85°C)",+ "symbol": "IKMIN",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 55,+ "max": 80,+ "conditions": "VKA = VREF, TA = -40°C to +85°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Minimum Cathode Current for Regulation (-40 to +125°C)",+ "symbol": "IKMIN",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 55,+ "max": 100,+ "conditions": "VKA = VREF, TA = -40°C to +125°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Off-State Current",+ "symbol": "IK(OFF)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.001,+ "max": 0.1,+ "conditions": "VKA = 18V, VREF = 0V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Dynamic Output Impedance",+ "symbol": "ZKA",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.25,+ "max": 0.4,+ "conditions": "VKA = VREF, f = <1kHz, IK = 0.1 to 15mA",+ "source_page": 3,+ "source": "datasheet"+ }+ ]+ }+ },+ "visibility": "public"+}
page.json+7−7@@ -1,6 +1,6 @@ { "slug": "tlv431aqfta",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Diodes Incorporated Voltage Reference, SOT-23. Datasheet-verified pinout, KiCad symbol/footprint/3D.", "tags": [@@ -25,11 +25,10 @@ "docs/tlv431aqfta-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html",- "tlv431aqfta-etched.step"+ "tlv431aqfta-etched.step",+ "tlv431aqfta-etched.glb" ],- "visibility": {- "public": true- },+ "visibility": "public", "author": { "name": "Ray" },@@ -533,5 +532,6 @@ } ] }- }-}+ },+ "org": "adom"+}