← Commit history

tlv2434aqdrq1: specified limits as data (metadata.characteristics, 60 rows from the datasheet)

Ray ·52302c4eb5 ·13d ago ·parent cfde75a
2 files changed +795−1
README.md+67
@@ -32,6 +32,73 @@ TLV2434AQDRQ1 from Texas Instruments, in a SOIC-14. Pinout and pin descriptions | Category | Amplifiers/Comparators | | Pins | 14 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Supply voltage (absolute maximum) | VDD |  |  | 12 | V |  | 3 |+| Input current (any input) | II | -5 |  | 5 | mA | Any input | 3 |+| Output current | IO | -50 |  | 50 | mA |  | 3 |+| Total current flowing into VDD+ |  | -50 |  | 50 | mA |  | 3 |+| Total current flowing out of VDD- |  | -50 |  | 50 | mA |  | 3 |+| Operating free-air temperature range (Q suffix) | TA | -40 |  | 125 | °C | Natural ventilation | 3 |+| Storage temperature range | Tstg | -65 |  | 150 | °C |  | 3 |+| Lead temperature |  |  |  | 260 | °C | 10 s, 1.6 mm (1/16 in) from case | 3 |+| Supply voltage (recommended) | VDD | 2.7 |  | 10 | V |  | 3 |+| Operating free-air temperature (recommended) | TA | -40 |  | 125 | °C | Natural ventilation | 3 |+| Rated power dissipation, D (14) package |  |  |  | 1022 | mW | TA ≤ 25°C; derating factor 7.6 mW/°C above TA = 25°C | 3 |+| Rated power dissipation, D (14) package |  |  |  | 900 | mW | TA = 70°C | 3 |+| Rated power dissipation, D (14) package |  |  |  | 777 | mW | TA = 85°C | 3 |+| Rated power dissipation, D (14) package |  |  |  | 450 | mW | TA = 125°C | 3 |+| Input offset voltage (TLV243xA) | VIO |  | 300 | 950 | μV | VDD = 3 V; VIC = 0, VO = 0, VDD± = ±1.5 V, RS = 50 Ω; TA = 25°C | 4 |+| Input offset voltage (TLV243xA), full range | VIO |  |  | 1600 | μV | VDD = 3 V; VIC = 0, VO = 0, VDD± = ±1.5 V, RS = 50 Ω; full range −40°C to 125°C | 4 |+| Input offset current, full range | IIO |  |  | 150 | pA | VDD = 3 V; full range −40°C to 125°C | 4 |+| Input bias current, full range | IIB |  |  | 300 | pA | VDD = 3 V; full range −40°C to 125°C | 4 |+| Common-mode input voltage range | VICR | 0 |  | 2.5 | V | VDD = 3 V; /VIO/ ≤ 5 mV, RS = 50 Ω; TA = 25°C | 4 |+| Common-mode input voltage range, full range | VICR | 0.2 |  | 2.2 | V | VDD = 3 V; /VIO/ ≤ 5 mV, RS = 50 Ω; full range −40°C to 125°C | 4 |+| High-level output voltage | VOH | 2.98 |  |  | V | VDD = 3 V; IO = −100 μA; TA = 25°C | 4 |+| High-level output voltage | VOH | 2.5 |  |  | V | VDD = 3 V; IO = −3 mA; TA = 25°C | 4 |+| High-level output voltage, full range | VOH | 2.25 |  |  | V | VDD = 3 V; IO = −3 mA; full range −40°C to 125°C | 4 |+| Low-level output voltage | VOL |  |  | 0.02 | V | VDD = 3 V; VIC = 1.5 V, IOL = 100 μA; TA = 25°C | 4 |+| Low-level output voltage | VOL |  |  | 0.83 | V | VDD = 3 V; VIC = 1.5 V, IOL = 3 mA; TA = 25°C | 4 |+| Low-level output voltage, full range | VOL |  |  | 1 | V | VDD = 3 V; VIC = 1.5 V, IOL = 3 mA; full range −40°C to 125°C | 4 |+| Large-signal differential voltage amplification | AVD | 1.5 | 2.5 |  | V/mV | VDD = 3 V; VIC = 2.5 V, VO = 1 V to 2 V, RL = 2 kΩ (referenced to 2.5 V); TA = 25°C | 4 |+| Large-signal differential voltage amplification, full range | AVD | 0.5 |  |  | V/mV | VDD = 3 V; VIC = 2.5 V, VO = 1 V to 2 V, RL = 2 kΩ (referenced to 2.5 V); full range −40°C to 125°C | 4 |+| Large-signal differential voltage amplification (RL = 1 MΩ) | AVD | 750 |  |  | V/mV | VDD = 3 V; VIC = 2.5 V, VO = 1 V to 2 V, RL = 1 MΩ (referenced to 2.5 V); TA = 25°C | 4 |+| Common-mode rejection ratio | CMRR | 63 | 83 |  | dB | VDD = 3 V; VIC = VICR min, VO = 1.5 V, RS = 50 Ω; TA = 25°C | 4 |+| Common-mode rejection ratio, full range | CMRR | 63 |  |  | dB | VDD = 3 V; VIC = VICR min, VO = 1.5 V, RS = 50 Ω; full range −40°C to 125°C | 4 |+| Supply voltage rejection ratio (ΔVDD±/ΔVIO) | kSVR | 80 | 95 |  | dB | VDD = 2.7 V to 8 V, VIC = VDD/2, no load; TA = 25°C | 4 |+| Supply voltage rejection ratio, full range | kSVR | 80 |  |  | dB | VDD = 2.7 V to 8 V, VIC = VDD/2, no load; full range −40°C to 125°C | 4 |+| Supply current per channel | IDD |  | 115 | 150 | μA | VDD = 3 V; VO = 1.5 V, no load; TA = 25°C | 4 |+| Supply current per channel, full range | IDD |  |  | 175 | μA | VDD = 3 V; VO = 1.5 V, no load; full range −40°C to 125°C | 5 |+| Slew rate at unity gain | SR | 0.15 | 0.25 |  | V/μs | VDD = 3 V; VO = 1 V to 2 V, RL = 2 kΩ, CL = 100 pF; TA = 25°C | 5 |+| Slew rate at unity gain, full range | SR | 0.1 |  |  | V/μs | VDD = 3 V; VO = 1 V to 2 V, RL = 2 kΩ, CL = 100 pF; full range −40°C to 125°C | 5 |+| Input offset voltage (TLV243xA) | VIO |  | 300 | 950 | μV | VDD = 5 V; VIC = 0, VO = 0, VDD± = ±2.5 V, RS = 50 Ω; TA = 25°C | 6 |+| Input offset voltage (TLV243xA), full range | VIO |  |  | 2000 | μV | VDD = 5 V; VIC = 0, VO = 0, VDD± = ±2.5 V, RS = 50 Ω; full range −40°C to 125°C | 6 |+| Input offset current, full range | IIO |  |  | 150 | pA | VDD = 5 V; full range −40°C to 125°C | 6 |+| Input bias current, full range | IIB |  |  | 300 | pA | VDD = 5 V; full range −40°C to 125°C | 6 |+| Common-mode input voltage range | VICR | 0 |  | 4.5 | V | VDD = 5 V; /VIO/ ≤ 5 mV, RS = 50 Ω; TA = 25°C | 6 |+| Common-mode input voltage range, full range | VICR | 0 |  | 4.2 | V | VDD = 5 V; /VIO/ ≤ 5 mV, RS = 50 Ω; full range −40°C to 125°C | 6 |+| High-level output voltage | VOH | 4.97 |  |  | V | VDD = 5 V; IOH = −100 μA; TA = 25°C | 6 |+| High-level output voltage | VOH | 4 | 4.35 |  | V | VDD = 5 V; IOH = −5 mA; TA = 25°C | 6 |+| High-level output voltage, full range | VOH | 4 |  |  | V | VDD = 5 V; IOH = −5 mA; full range −40°C to 125°C | 6 |+| Low-level output voltage | VOL |  |  | 0.01 | V | VDD = 5 V; VIC = 2.5 V, IOL = 100 μA; TA = 25°C | 6 |+| Low-level output voltage | VOL |  |  | 0.8 | V | VDD = 5 V; VIC = 2.5 V, IOL = 5 mA; TA = 25°C | 6 |+| Low-level output voltage, full range | VOL |  |  | 1.25 | V | VDD = 5 V; VIC = 2.5 V, IOL = 5 mA; full range −40°C to 125°C | 6 |+| Large-signal differential voltage amplification | AVD | 2.5 | 3.8 |  | V/mV | VDD = 5 V; VIC = 2.5 V, VO = 1 V to 4 V, RL = 2 kΩ (referenced to 2.5 V); TA = 25°C | 6 |+| Large-signal differential voltage amplification, full range | AVD | 0.5 |  |  | V/mV | VDD = 5 V; VIC = 2.5 V, VO = 1 V to 4 V, RL = 2 kΩ (referenced to 2.5 V); full range −40°C to 125°C | 6 |+| Large-signal differential voltage amplification (RL = 1 MΩ) | AVD | 950 |  |  | V/mV | VDD = 5 V; VIC = 2.5 V, VO = 1 V to 4 V, RL = 1 MΩ (referenced to 2.5 V); TA = 25°C | 6 |+| Common-mode rejection ratio | CMRR | 63 | 90 |  | dB | VDD = 5 V; VIC = VICR min, VO = 2.5 V, RS = 50 Ω; TA = 25°C | 6 |+| Common-mode rejection ratio, full range | CMRR | 63 |  |  | dB | VDD = 5 V; VIC = VICR min, VO = 2.5 V, RS = 50 Ω; full range −40°C to 125°C | 6 |+| Supply voltage rejection ratio (ΔVDD/ΔVIO) | kSVR | 80 | 95 |  | dB | VDD = 4.4 V to 8 V, VIC = VDD/2, no load; TA = 25°C | 6 |+| Supply voltage rejection ratio, full range | kSVR | 80 |  |  | dB | VDD = 4.4 V to 8 V, VIC = VDD/2, no load; full range −40°C to 125°C | 6 |+| Supply current per channel | IDD |  | 115 | 150 | μA | VDD = 5 V; VO = 2.5 V, no load; TA = 25°C | 6 |+| Supply current per channel, full range | IDD |  |  | 175 | μA | VDD = 5 V; VO = 2.5 V, no load; full range −40°C to 125°C | 6 |+| Slew rate at unity gain | SR | 0.15 | 0.25 |  | V/μs | VDD = 5 V; VO = 1.5 V to 3.5 V, RL = 2 kΩ, CL = 100 pF; TA = 25°C | 7 |+| Slew rate at unity gain, full range | SR | 0.1 |  |  | V/μs | VDD = 5 V; VO = 1.5 V to 3.5 V, RL = 2 kΩ, CL = 100 pF; full range −40°C to 125°C | 7 |+ ## CAD (KiCad official)  - Symbol: `TLV2434AQDRQ1`
page.json+728−1
@@ -216,6 +216,733 @@       "Package": "SOIC-14",       "Category": "Amplifiers/Comparators",       "Pins": "14"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "467245f5275e2776",+      "rows": [+        {+          "name": "Supply voltage (absolute maximum)",+          "symbol": "VDD",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 12,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input current (any input)",+          "symbol": "II",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "Any input",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output current",+          "symbol": "IO",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Total current flowing into VDD+",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Total current flowing out of VDD-",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature range (Q suffix)",+          "symbol": "TA",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "Natural ventilation",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Lead temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "10 s, 1.6 mm (1/16 in) from case",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage (recommended)",+          "symbol": "VDD",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2.7,+          "typ": null,+          "max": 10,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature (recommended)",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "Natural ventilation",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Rated power dissipation, D (14) package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 1022,+          "conditions": "TA ≤ 25°C; derating factor 7.6 mW/°C above TA = 25°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Rated power dissipation, D (14) package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 900,+          "conditions": "TA = 70°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Rated power dissipation, D (14) package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 777,+          "conditions": "TA = 85°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Rated power dissipation, D (14) package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 450,+          "conditions": "TA = 125°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage (TLV243xA)",+          "symbol": "VIO",+          "kind": "electrical",+          "unit": "μV",+          "min": null,+          "typ": 300,+          "max": 950,+          "conditions": "VDD = 3 V; VIC = 0, VO = 0, VDD± = ±1.5 V, RS = 50 Ω; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage (TLV243xA), full range",+          "symbol": "VIO",+          "kind": "electrical",+          "unit": "μV",+          "min": null,+          "typ": null,+          "max": 1600,+          "conditions": "VDD = 3 V; VIC = 0, VO = 0, VDD± = ±1.5 V, RS = 50 Ω; full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input offset current, full range",+          "symbol": "IIO",+          "kind": "electrical",+          "unit": "pA",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "VDD = 3 V; full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input bias current, full range",+          "symbol": "IIB",+          "kind": "electrical",+          "unit": "pA",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "VDD = 3 V; full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 2.5,+          "conditions": "VDD = 3 V; |VIO| ≤ 5 mV, RS = 50 Ω; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range, full range",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": 0.2,+          "typ": null,+          "max": 2.2,+          "conditions": "VDD = 3 V; |VIO| ≤ 5 mV, RS = 50 Ω; full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 2.98,+          "typ": null,+          "max": null,+          "conditions": "VDD = 3 V; IO = −100 μA; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 2.5,+          "typ": null,+          "max": null,+          "conditions": "VDD = 3 V; IO = −3 mA; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage, full range",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 2.25,+          "typ": null,+          "max": null,+          "conditions": "VDD = 3 V; IO = −3 mA; full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.02,+          "conditions": "VDD = 3 V; VIC = 1.5 V, IOL = 100 μA; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.83,+          "conditions": "VDD = 3 V; VIC = 1.5 V, IOL = 3 mA; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage, full range",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VDD = 3 V; VIC = 1.5 V, IOL = 3 mA; full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 1.5,+          "typ": 2.5,+          "max": null,+          "conditions": "VDD = 3 V; VIC = 2.5 V, VO = 1 V to 2 V, RL = 2 kΩ (referenced to 2.5 V); TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification, full range",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 0.5,+          "typ": null,+          "max": null,+          "conditions": "VDD = 3 V; VIC = 2.5 V, VO = 1 V to 2 V, RL = 2 kΩ (referenced to 2.5 V); full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification (RL = 1 MΩ)",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 750,+          "typ": null,+          "max": null,+          "conditions": "VDD = 3 V; VIC = 2.5 V, VO = 1 V to 2 V, RL = 1 MΩ (referenced to 2.5 V); TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 63,+          "typ": 83,+          "max": null,+          "conditions": "VDD = 3 V; VIC = VICR min, VO = 1.5 V, RS = 50 Ω; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio, full range",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 63,+          "typ": null,+          "max": null,+          "conditions": "VDD = 3 V; VIC = VICR min, VO = 1.5 V, RS = 50 Ω; full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage rejection ratio (ΔVDD±/ΔVIO)",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 80,+          "typ": 95,+          "max": null,+          "conditions": "VDD = 2.7 V to 8 V, VIC = VDD/2, no load; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage rejection ratio, full range",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 80,+          "typ": null,+          "max": null,+          "conditions": "VDD = 2.7 V to 8 V, VIC = VDD/2, no load; full range −40°C to 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply current per channel",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 115,+          "max": 150,+          "conditions": "VDD = 3 V; VO = 1.5 V, no load; TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply current per channel, full range",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": null,+          "max": 175,+          "conditions": "VDD = 3 V; VO = 1.5 V, no load; full range −40°C to 125°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Slew rate at unity gain",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/μs",+          "min": 0.15,+          "typ": 0.25,+          "max": null,+          "conditions": "VDD = 3 V; VO = 1 V to 2 V, RL = 2 kΩ, CL = 100 pF; TA = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Slew rate at unity gain, full range",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/μs",+          "min": 0.1,+          "typ": null,+          "max": null,+          "conditions": "VDD = 3 V; VO = 1 V to 2 V, RL = 2 kΩ, CL = 100 pF; full range −40°C to 125°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage (TLV243xA)",+          "symbol": "VIO",+          "kind": "electrical",+          "unit": "μV",+          "min": null,+          "typ": 300,+          "max": 950,+          "conditions": "VDD = 5 V; VIC = 0, VO = 0, VDD± = ±2.5 V, RS = 50 Ω; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage (TLV243xA), full range",+          "symbol": "VIO",+          "kind": "electrical",+          "unit": "μV",+          "min": null,+          "typ": null,+          "max": 2000,+          "conditions": "VDD = 5 V; VIC = 0, VO = 0, VDD± = ±2.5 V, RS = 50 Ω; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Input offset current, full range",+          "symbol": "IIO",+          "kind": "electrical",+          "unit": "pA",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "VDD = 5 V; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Input bias current, full range",+          "symbol": "IIB",+          "kind": "electrical",+          "unit": "pA",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "VDD = 5 V; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 4.5,+          "conditions": "VDD = 5 V; |VIO| ≤ 5 mV, RS = 50 Ω; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range, full range",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 4.2,+          "conditions": "VDD = 5 V; |VIO| ≤ 5 mV, RS = 50 Ω; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4.97,+          "typ": null,+          "max": null,+          "conditions": "VDD = 5 V; IOH = −100 μA; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4,+          "typ": 4.35,+          "max": null,+          "conditions": "VDD = 5 V; IOH = −5 mA; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage, full range",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4,+          "typ": null,+          "max": null,+          "conditions": "VDD = 5 V; IOH = −5 mA; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.01,+          "conditions": "VDD = 5 V; VIC = 2.5 V, IOL = 100 μA; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.8,+          "conditions": "VDD = 5 V; VIC = 2.5 V, IOL = 5 mA; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage, full range",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.25,+          "conditions": "VDD = 5 V; VIC = 2.5 V, IOL = 5 mA; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 2.5,+          "typ": 3.8,+          "max": null,+          "conditions": "VDD = 5 V; VIC = 2.5 V, VO = 1 V to 4 V, RL = 2 kΩ (referenced to 2.5 V); TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification, full range",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 0.5,+          "typ": null,+          "max": null,+          "conditions": "VDD = 5 V; VIC = 2.5 V, VO = 1 V to 4 V, RL = 2 kΩ (referenced to 2.5 V); full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification (RL = 1 MΩ)",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 950,+          "typ": null,+          "max": null,+          "conditions": "VDD = 5 V; VIC = 2.5 V, VO = 1 V to 4 V, RL = 1 MΩ (referenced to 2.5 V); TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 63,+          "typ": 90,+          "max": null,+          "conditions": "VDD = 5 V; VIC = VICR min, VO = 2.5 V, RS = 50 Ω; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio, full range",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 63,+          "typ": null,+          "max": null,+          "conditions": "VDD = 5 V; VIC = VICR min, VO = 2.5 V, RS = 50 Ω; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage rejection ratio (ΔVDD/ΔVIO)",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 80,+          "typ": 95,+          "max": null,+          "conditions": "VDD = 4.4 V to 8 V, VIC = VDD/2, no load; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage rejection ratio, full range",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 80,+          "typ": null,+          "max": null,+          "conditions": "VDD = 4.4 V to 8 V, VIC = VDD/2, no load; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Supply current per channel",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 115,+          "max": 150,+          "conditions": "VDD = 5 V; VO = 2.5 V, no load; TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Supply current per channel, full range",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": null,+          "max": 175,+          "conditions": "VDD = 5 V; VO = 2.5 V, no load; full range −40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Slew rate at unity gain",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/μs",+          "min": 0.15,+          "typ": 0.25,+          "max": null,+          "conditions": "VDD = 5 V; VO = 1.5 V to 3.5 V, RL = 2 kΩ, CL = 100 pF; TA = 25°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Slew rate at unity gain, full range",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/μs",+          "min": 0.1,+          "typ": null,+          "max": null,+          "conditions": "VDD = 5 V; VO = 1.5 V to 3.5 V, RL = 2 kΩ, CL = 100 pF; full range −40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -257,4 +984,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}