← Commit history
page.json+8−5@@ -32,7 +32,7 @@ "number": "1", "name": "1OUT", "type": "output",- "description": "Output of op-amp channel 1. Push-pull output stage rated to drive 100\u03a9 loads."+ "description": "Output of op-amp channel 1. Push-pull output stage rated to drive 100Ω loads." }, { "number": "2",@@ -50,7 +50,7 @@ "number": "4", "name": "VCC-", "type": "power_in",- "description": "Negative supply rail. For single-supply operation tie to GND; for split-supply operation connect to the negative rail. Total supply voltage (VCC+ \u2212 VCC\u2212) up to 36V."+ "description": "Negative supply rail. For single-supply operation tie to GND; for split-supply operation connect to the negative rail. Total supply voltage (VCC+ − VCC−) up to 36V." }, { "number": "5",@@ -68,13 +68,13 @@ "number": "7", "name": "2OUT", "type": "output",- "description": "Output of op-amp channel 2. Push-pull output stage rated to drive 100\u03a9 loads."+ "description": "Output of op-amp channel 2. Push-pull output stage rated to drive 100Ω loads." }, { "number": "8", "name": "VCC+", "type": "power_in",- "description": "Positive supply rail. Total supply voltage (VCC+ \u2212 VCC\u2212) up to 36V absolute maximum."+ "description": "Positive supply rail. Total supply voltage (VCC+ − VCC−) up to 36V absolute maximum." } ], "provenance": {@@ -138,5 +138,8 @@ "docs/tle2062idr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }