← Commit history

tlc3704idr: specified limits as data (metadata.characteristics, 37 rows from the datasheet)

Ray ·4a2562355a ·11d ago ·parent 9d9d513
2 files changed +496−1
README.md+44
@@ -32,6 +32,50 @@ TLC3704IDR from Texas Instruments, in a SOIC-14. Pinout and pin descriptions ext | Category | Amplifiers/Comparators | | Pins | 14 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Supply voltage | VDD | 3 | 5 | 16 | V | TLC3704I recommended operating conditions | 4 |+| Operating free-air temperature | TA | -40 |  | 85 | °C | TLC3704I | 4 |+| High-level output current | IOH |  |  | -20 | mA | TLC3704I | 4 |+| Low-level output current | IOL |  |  | 20 | mA | TLC3704I | 4 |+| Common-mode input voltage | VIC | -0.2 |  |  | V | TLC3704I; printed maximum is VDD − 1.5 | 4 |+| Supply voltage range | VDD | -0.3 |  | 18 | V | All voltage values with respect to network ground (Note 1) | 2 |+| Differential input voltage | VID | -18 |  | 18 | V | Note 2: differential voltages are at IN+ with respect to IN− | 2 |+| Input voltage range | VI | -0.3 |  |  | V | Printed upper limit is VDD | 2 |+| Output voltage range | VO | -0.3 |  |  | V | Printed upper limit is VDD | 2 |+| Input current | II | -5 |  | 5 | mA |  | 2 |+| Output current (each output) | IO | -20 |  | 20 | mA | Each output | 2 |+| Total supply current into VDD |  |  |  | 40 | mA |  | 2 |+| Total current out of GND |  |  |  | 60 | mA |  | 2 |+| Operating free-air temperature range | TA | -40 |  | 85 | °C | TLC3704I | 2 |+| Storage temperature range |  | -65 |  | 150 | °C |  | 2 |+| Lead temperature |  |  |  | 260 | °C | 1,6 mm (1/16 inch) from case for 10 seconds: D or N package | 2 |+| Input offset voltage | VIO |  | 1.2 | 5 | mV | VDD = 5 V to 10 V, VIC = VICRmin, 25°C | 4 |+| Input offset voltage | VIO |  |  | 7 | mV | VDD = 5 V to 10 V, VIC = VICRmin, −40°C to 85°C | 4 |+| Input offset current | IIO |  |  | 1 | nA | VIC = 2.5 V, 85°C | 4 |+| Input bias current | IIB |  |  | 2 | nA | VIC = 2.5 V, 85°C | 4 |+| Common-mode input voltage range | VICR | 0 |  |  | V | 25°C; printed maximum is VDD − 1 | 4 |+| Common-mode rejection ratio | CMRR | 84 |  |  | dB | VIC = VICRmin, 25°C | 4 |+| Common-mode rejection ratio | CMRR | 83 |  |  | dB | VIC = VICRmin, −40°C | 4 |+| Supply-voltage rejection ratio | kSVR | 85 |  |  | dB | VDD = 5 V to 10 V, 25°C | 4 |+| Supply-voltage rejection ratio | kSVR | 83 |  |  | dB | VDD = 5 V to 10 V, −40°C | 4 |+| High-level output voltage | VOH | 4.5 | 4.7 |  | V | VID = 1 V, IOH = −4 mA, 25°C | 4 |+| High-level output voltage | VOH | 4.3 |  |  | V | VID = 1 V, IOH = −4 mA, 85°C | 4 |+| Low-level output voltage | VOL |  | 210 | 300 | mV | VID = −1 V, IOH = 4 mA, 25°C | 4 |+| Low-level output voltage | VOL |  |  | 400 | mV | VID = −1 V, IOH = 4 mA, 85°C | 4 |+| Supply current (all four comparators) | IDD |  | 35 | 80 | µA | Outputs low, No load, 25°C | 4 |+| Supply current (all four comparators) | IDD |  |  | 125 | µA | Outputs low, No load, −40°C to 85°C | 4 |+| Input offset current | IIO |  | 1 |  | pA | VIC = 2.5 V, 25°C | 4 |+| Input bias current | IIB |  | 5 |  | pA | VIC = 2.5 V, 25°C | 4 |+| Power rating |  |  |  | 950 | mW | D package, TA ≤ 25°C | 3 |+| Power rating |  |  |  | 608 | mW | D package, TA = 70°C | 3 |+| Power rating |  |  |  | 494 | mW | D package, TA = 85°C | 3 |+| Derating factor above TA = 25°C |  |  | 7.6 |  | mW/°C | D package, above TA = 25°C | 3 |+ ## CAD (KiCad official)  - Symbol: `TLC3704IDR`
page.json+452−1
@@ -215,6 +215,457 @@       "Package": "SOIC-14",       "Category": "Amplifiers/Comparators",       "Pins": "14"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "ffd091c311885dff",+      "rows": [+        {+          "name": "Supply voltage",+          "symbol": "VDD",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 3,+          "typ": 5,+          "max": 16,+          "conditions": "TLC3704I recommended operating conditions",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "TLC3704I",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "High-level output current",+          "symbol": "IOH",+          "kind": "recommended_operating",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": -20,+          "conditions": "TLC3704I",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Low-level output current",+          "symbol": "IOL",+          "kind": "recommended_operating",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "TLC3704I",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage",+          "symbol": "VIC",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.2,+          "typ": null,+          "max": null,+          "conditions": "TLC3704I; printed maximum is VDD − 1.5",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage range",+          "symbol": "VDD",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 18,+          "conditions": "All voltage values with respect to network ground (Note 1)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Differential input voltage",+          "symbol": "VID",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -18,+          "typ": null,+          "max": 18,+          "conditions": "Note 2: differential voltages are at IN+ with respect to IN−",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range",+          "symbol": "VI",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "Printed upper limit is VDD",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output voltage range",+          "symbol": "VO",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "Printed upper limit is VDD",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input current",+          "symbol": "II",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output current (each output)",+          "symbol": "IO",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "Each output",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total supply current into VDD",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total current out of GND",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature range",+          "symbol": "TA",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "TLC3704I",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Lead temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "1,6 mm (1/16 inch) from case for 10 seconds: D or N package",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage",+          "symbol": "VIO",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": 1.2,+          "max": 5,+          "conditions": "VDD = 5 V to 10 V, VIC = VICRmin, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage",+          "symbol": "VIO",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 7,+          "conditions": "VDD = 5 V to 10 V, VIC = VICRmin, −40°C to 85°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input offset current",+          "symbol": "IIO",+          "kind": "electrical",+          "unit": "nA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VIC = 2.5 V, 85°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input bias current",+          "symbol": "IIB",+          "kind": "electrical",+          "unit": "nA",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "VIC = 2.5 V, 85°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": null,+          "conditions": "25°C; printed maximum is VDD − 1",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 84,+          "typ": null,+          "max": null,+          "conditions": "VIC = VICRmin, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 83,+          "typ": null,+          "max": null,+          "conditions": "VIC = VICRmin, −40°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply-voltage rejection ratio",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 85,+          "typ": null,+          "max": null,+          "conditions": "VDD = 5 V to 10 V, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply-voltage rejection ratio",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 83,+          "typ": null,+          "max": null,+          "conditions": "VDD = 5 V to 10 V, −40°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4.5,+          "typ": 4.7,+          "max": null,+          "conditions": "VID = 1 V, IOH = −4 mA, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4.3,+          "typ": null,+          "max": null,+          "conditions": "VID = 1 V, IOH = −4 mA, 85°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": 210,+          "max": 300,+          "conditions": "VID = −1 V, IOH = 4 mA, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 400,+          "conditions": "VID = −1 V, IOH = 4 mA, 85°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply current (all four comparators)",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 35,+          "max": 80,+          "conditions": "Outputs low, No load, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply current (all four comparators)",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "Outputs low, No load, −40°C to 85°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input offset current",+          "symbol": "IIO",+          "kind": "electrical",+          "unit": "pA",+          "min": null,+          "typ": 1,+          "max": null,+          "conditions": "VIC = 2.5 V, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input bias current",+          "symbol": "IIB",+          "kind": "electrical",+          "unit": "pA",+          "min": null,+          "typ": 5,+          "max": null,+          "conditions": "VIC = 2.5 V, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Power rating",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 950,+          "conditions": "D package, TA ≤ 25°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Power rating",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 608,+          "conditions": "D package, TA = 70°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Power rating",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 494,+          "conditions": "D package, TA = 85°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Derating factor above TA = 25°C",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW/°C",+          "min": null,+          "typ": 7.6,+          "max": null,+          "conditions": "D package, above TA = 25°C",+          "source_page": 3,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -256,4 +707,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}