← Commit history

tlc2264aqpwrq1: specified limits as data (metadata.characteristics, 58 rows from the datasheet)

Ray ·b42d25759e · ·parent a838ab8
2 files changed +769−1
README.md+65
@@ -32,6 +32,71 @@ TLC2264AQPWRQ1 from Texas Instruments, in a TSSOP-14. Pinout and pin description | Category | Amplifiers/Comparators | | Pins | 14 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input offset voltage (VDD = 5 V table), 25°C | VIO |  | 300 | 950 | µV |  | 9 |+| Input offset voltage (VDD = 5 V table), full range | VIO |  |  | 1500 | µV | Full range (−40°C to 125°C) | 9 |+| Common-mode input voltage range (VDD = 5 V table), 25°C | VICR | -0.3 |  | 4.2 | V | RS = 50 Ω, /VIO/ ≤ 5 mV | 9 |+| Common-mode input voltage range (VDD = 5 V table), full range | VICR | 0 |  | 3.5 | V | RS = 50 Ω, /VIO/ ≤ 5 mV; Full range (−40°C to 125°C) | 9 |+| High-level output voltage (VDD = 5 V table), 25°C | VOH | 4.85 | 4.94 |  | V | IOH = −100 µA | 9 |+| High-level output voltage (VDD = 5 V table), full range | VOH | 4.82 |  |  | V | IOH = −100 µA; Full range (−40°C to 125°C) | 9 |+| High-level output voltage (VDD = 5 V table), 25°C | VOH | 4.7 | 4.85 |  | V | IOH = −400 µA | 9 |+| High-level output voltage (VDD = 5 V table), full range | VOH | 4.5 |  |  | V | IOH = −400 µA; Full range (−40°C to 125°C) | 9 |+| Low-level output voltage (VDD = 5 V table), 25°C | VOL |  | 0.09 | 0.15 | V | VIC = 2.5 V, IOL = 500 µA | 9 |+| Low-level output voltage (VDD = 5 V table), full range | VOL |  |  | 0.15 | V | VIC = 2.5 V, IOL = 500 µA; Full range (−40°C to 125°C) | 9 |+| Low-level output voltage (VDD = 5 V table), 25°C | VOL |  | 0.7 | 1 | V | VIC = 2.5 V, IOL = 4 A | 9 |+| Low-level output voltage (VDD = 5 V table), full range | VOL |  |  | 1.2 | V | VIC = 2.5 V, IOL = 4 A; Full range (−40°C to 125°C) | 9 |+| Large-signal differential voltage amplification (VDD = 5 V table), 25°C | AVD | 80 | 170 |  | V/mV | VIC = 2.5 V, VO = 1 V to 4 V, RL = 50 kΩ | 9 |+| Large-signal differential voltage amplification (VDD = 5 V table), full range | AVD | 50 |  |  | V/mV | VIC = 2.5 V, VO = 1 V to 4 V, RL = 50 kΩ; Full range (−40°C to 125°C) | 9 |+| Common-mode rejection ratio (VDD = 5 V table), 25°C | CMRR | 70 | 83 |  | dB | VIC = 0 to 2.7 V, VO = 2.5 V | 9 |+| Common-mode rejection ratio (VDD = 5 V table), full range | CMRR | 70 |  |  | dB | VIC = 0 to 2.7 V, VO = 2.5 V, RS = 50 Ω; Full range (−40°C to 125°C) | 9 |+| Supply-voltage rejection ratio (VDD = 5 V table), 25°C | kSVR | 80 | 95 |  | dB | VDD = 4.4 V to 16 V | 9 |+| Supply-voltage rejection ratio (VDD = 5 V table), full range | kSVR | 80 |  |  | dB | VDD = 4.4 V to 16 V, VIC = VDD/2, No load; Full range (−40°C to 125°C) | 9 |+| Supply current, four amplifiers (VDD = 5 V table), 25°C | IDD |  | 0.8 | 1 | mA | VO = 2.5 V, No load | 9 |+| Supply current, four amplifiers (VDD = 5 V table), full range | IDD |  |  | 1 | mA | VO = 2.5 V, No load; Full range (−40°C to 125°C) | 9 |+| Common-mode input voltage range (VDD± = ±5 V table), 25°C | VICR | -5.3 |  | 4.2 | V | RS = 50 Ω, /VIO/ ≤ 5 mV | 11 |+| Common-mode input voltage range (VDD± = ±5 V table), full range | VICR | -5 |  | 3.5 | V | RS = 50 Ω, /VIO/ ≤ 5 mV; Full range (−40°C to 125°C) | 11 |+| Maximum positive peak output voltage (±5 V), 25°C | VOM+ | 4.85 | 4.94 |  | V | IO = −100 µA | 11 |+| Maximum positive peak output voltage (±5 V), full range | VOM+ | 4.82 |  |  | V | IO = −100 µA; Full range (−40°C to 125°C) | 11 |+| Maximum positive peak output voltage (±5 V), 25°C | VOM+ | 4.7 | 4.85 |  | V | IO = −400 µA | 11 |+| Maximum positive peak output voltage (±5 V), full range | VOM+ | 4.5 |  |  | V | IO = −400 µA; Full range (−40°C to 125°C) | 11 |+| Maximum negative peak output voltage (±5 V), 25°C | VOM− | -4.85 | -4.91 |  | V | VIC = 0, IO = 500 µA | 11 |+| Maximum negative peak output voltage (±5 V), full range | VOM− | -4.85 |  |  | V | VIC = 0, IO = 500 µA; Full range (−40°C to 125°C) | 11 |+| Maximum negative peak output voltage (±5 V), 25°C | VOM− | -4 | -4.3 |  | V | VIC = 0, IO = 4 A | 11 |+| Maximum negative peak output voltage (±5 V), full range | VOM− | -3.8 |  |  | V | VIC = 0, IO = 4 A; Full range (−40°C to 125°C) | 11 |+| Large-signal differential voltage amplification (±5 V), 25°C | AVD | 80 | 200 |  | V/mV | VO = ±4 V, RL = 50 kΩ | 11 |+| Large-signal differential voltage amplification (±5 V), full range | AVD | 50 |  |  | V/mV | VO = ±4 V, RL = 50 kΩ; Full range (−40°C to 125°C) | 11 |+| Common-mode rejection ratio (±5 V), 25°C | CMRR | 75 | 88 |  | dB | VIC = −5 V to 2.7 V | 11 |+| Common-mode rejection ratio (±5 V), full range | CMRR | 75 |  |  | dB | VIC = −5 V to 2.7 V, VO = 0, RS = 50 Ω; Full range (−40°C to 125°C) | 11 |+| Supply-voltage rejection ratio (±5 V), 25°C | kSVR | 80 | 95 |  | dB | VDD± = ±2.2 V to ±8 V | 11 |+| Supply-voltage rejection ratio (±5 V), full range | kSVR | 80 |  |  | dB | VDD± = ±2.2 V to ±8 V, VIC = VDD/2, No load; Full range (−40°C to 125°C) | 11 |+| Supply current, four amplifiers (±5 V), 25°C | IDD |  | 0.85 | 1 | mA | VO = 0, No load | 11 |+| Supply current, four amplifiers (±5 V), full range | IDD |  |  | 1 | mA | VO = 0, No load; Full range (−40°C to 125°C) | 11 |+| Slew rate at unity gain (VDD = 5 V table), 25°C | SR | 0.35 | 0.55 |  | V/µs | VO = 0.5 V to 3.5 V, RL = 50 kΩ, CL = 100 pF | 10 |+| Slew rate at unity gain (VDD = 5 V table), full range | SR | 0.25 |  |  | V/µs | VO = 0.5 V to 3.5 V, RL = 50 kΩ, CL = 100 pF; Full range (−40°C to 125°C) | 10 |+| Slew rate at unity gain (±5 V table), 25°C | SR | 0.35 | 0.55 |  | V/µs | VO = ±2 V, RL = 50 kΩ, CL = 100 pF | 12 |+| Slew rate at unity gain (±5 V table), full range | SR | 0.25 |  |  | V/µs | VO = ±2 V, CL = 100 pF, RL = 50 kΩ; Full range (−40°C to 125°C) | 12 |+| Input/output: Absolute maximum supply voltage, VDD+ | VDD+ |  |  | 8 | V | See Note 1 | 4 |+| Absolute maximum supply voltage, VDD− | VDD− | -8 |  |  | V | See Note 1 | 4 |+| Differential input voltage | VID | -16 |  | 16 | V | See Note 2 | 4 |+| Input current (each input) | II | -5 |  | 5 | mA |  | 4 |+| Output current | IO | -50 |  | 50 | mA |  | 4 |+| Total current into VDD+ |  | -50 |  | 50 | mA |  | 4 |+| Total current out of VDD− |  | -50 |  | 50 | mA |  | 4 |+| Storage temperature range | Tstg | -65 |  | 150 | °C |  | 4 |+| Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds |  |  |  | 260 | °C | D or PW package | 4 |+| Supply voltage, VDD± (recommended) | VDD± | 2.2 |  | 8 | V |  | 4 |+| Operating free-air temperature, TA (recommended) | TA | -40 |  | 125 | °C |  | 4 |+| Continuous total dissipation, PW-14 package |  |  |  | 750 | mW | TA ≤ 25°C | 4 |+| Continuous total dissipation, PW-14 package |  |  |  | 480 | mW | TA = 70°C | 4 |+| Continuous total dissipation, PW-14 package |  |  |  | 389 | mW | TA = 85°C | 4 |+| Continuous total dissipation, PW-14 package |  |  |  | 150 | mW | TA = 125°C | 4 |+| Derating factor, PW-14 package |  |  | 6 |  | mW/°C | Above TA = 25°C | 4 |+ ## CAD (KiCad official)  - Symbol: `TLC2264AQPWRQ1`
page.json+704−1
@@ -214,6 +214,709 @@       "Package": "TSSOP-14",       "Category": "Amplifiers/Comparators",       "Pins": "14"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "bb43fda6e2682b1e",+      "rows": [+        {+          "name": "Input offset voltage (VDD = 5 V table), 25°C",+          "symbol": "VIO",+          "kind": "tolerance",+          "unit": "µV",+          "min": null,+          "typ": 300,+          "max": 950,+          "conditions": "",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage (VDD = 5 V table), full range",+          "symbol": "VIO",+          "kind": "tolerance",+          "unit": "µV",+          "min": null,+          "typ": null,+          "max": 1500,+          "conditions": "Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range (VDD = 5 V table), 25°C",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 4.2,+          "conditions": "RS = 50 Ω, |VIO| ≤ 5 mV",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range (VDD = 5 V table), full range",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 3.5,+          "conditions": "RS = 50 Ω, |VIO| ≤ 5 mV; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage (VDD = 5 V table), 25°C",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4.85,+          "typ": 4.94,+          "max": null,+          "conditions": "IOH = −100 µA",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage (VDD = 5 V table), full range",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4.82,+          "typ": null,+          "max": null,+          "conditions": "IOH = −100 µA; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage (VDD = 5 V table), 25°C",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4.7,+          "typ": 4.85,+          "max": null,+          "conditions": "IOH = −400 µA",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "High-level output voltage (VDD = 5 V table), full range",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 4.5,+          "typ": null,+          "max": null,+          "conditions": "IOH = −400 µA; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage (VDD = 5 V table), 25°C",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 0.09,+          "max": 0.15,+          "conditions": "VIC = 2.5 V, IOL = 500 µA",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage (VDD = 5 V table), full range",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.15,+          "conditions": "VIC = 2.5 V, IOL = 500 µA; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage (VDD = 5 V table), 25°C",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 0.7,+          "max": 1,+          "conditions": "VIC = 2.5 V, IOL = 4 A",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Low-level output voltage (VDD = 5 V table), full range",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.2,+          "conditions": "VIC = 2.5 V, IOL = 4 A; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification (VDD = 5 V table), 25°C",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 80,+          "typ": 170,+          "max": null,+          "conditions": "VIC = 2.5 V, VO = 1 V to 4 V, RL = 50 kΩ",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification (VDD = 5 V table), full range",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 50,+          "typ": null,+          "max": null,+          "conditions": "VIC = 2.5 V, VO = 1 V to 4 V, RL = 50 kΩ; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio (VDD = 5 V table), 25°C",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 70,+          "typ": 83,+          "max": null,+          "conditions": "VIC = 0 to 2.7 V, VO = 2.5 V",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio (VDD = 5 V table), full range",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 70,+          "typ": null,+          "max": null,+          "conditions": "VIC = 0 to 2.7 V, VO = 2.5 V, RS = 50 Ω; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Supply-voltage rejection ratio (VDD = 5 V table), 25°C",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 80,+          "typ": 95,+          "max": null,+          "conditions": "VDD = 4.4 V to 16 V",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Supply-voltage rejection ratio (VDD = 5 V table), full range",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 80,+          "typ": null,+          "max": null,+          "conditions": "VDD = 4.4 V to 16 V, VIC = VDD/2, No load; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Supply current, four amplifiers (VDD = 5 V table), 25°C",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 0.8,+          "max": 1,+          "conditions": "VO = 2.5 V, No load",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Supply current, four amplifiers (VDD = 5 V table), full range",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VO = 2.5 V, No load; Full range (−40°C to 125°C)",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range (VDD± = ±5 V table), 25°C",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": -5.3,+          "typ": null,+          "max": 4.2,+          "conditions": "RS = 50 Ω, |VIO| ≤ 5 mV",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage range (VDD± = ±5 V table), full range",+          "symbol": "VICR",+          "kind": "electrical",+          "unit": "V",+          "min": -5,+          "typ": null,+          "max": 3.5,+          "conditions": "RS = 50 Ω, |VIO| ≤ 5 mV; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Maximum positive peak output voltage (±5 V), 25°C",+          "symbol": "VOM+",+          "kind": "electrical",+          "unit": "V",+          "min": 4.85,+          "typ": 4.94,+          "max": null,+          "conditions": "IO = −100 µA",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Maximum positive peak output voltage (±5 V), full range",+          "symbol": "VOM+",+          "kind": "electrical",+          "unit": "V",+          "min": 4.82,+          "typ": null,+          "max": null,+          "conditions": "IO = −100 µA; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Maximum positive peak output voltage (±5 V), 25°C",+          "symbol": "VOM+",+          "kind": "electrical",+          "unit": "V",+          "min": 4.7,+          "typ": 4.85,+          "max": null,+          "conditions": "IO = −400 µA",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Maximum positive peak output voltage (±5 V), full range",+          "symbol": "VOM+",+          "kind": "electrical",+          "unit": "V",+          "min": 4.5,+          "typ": null,+          "max": null,+          "conditions": "IO = −400 µA; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Maximum negative peak output voltage (±5 V), 25°C",+          "symbol": "VOM−",+          "kind": "electrical",+          "unit": "V",+          "min": -4.85,+          "typ": -4.91,+          "max": null,+          "conditions": "VIC = 0, IO = 500 µA",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Maximum negative peak output voltage (±5 V), full range",+          "symbol": "VOM−",+          "kind": "electrical",+          "unit": "V",+          "min": -4.85,+          "typ": null,+          "max": null,+          "conditions": "VIC = 0, IO = 500 µA; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Maximum negative peak output voltage (±5 V), 25°C",+          "symbol": "VOM−",+          "kind": "electrical",+          "unit": "V",+          "min": -4,+          "typ": -4.3,+          "max": null,+          "conditions": "VIC = 0, IO = 4 A",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Maximum negative peak output voltage (±5 V), full range",+          "symbol": "VOM−",+          "kind": "electrical",+          "unit": "V",+          "min": -3.8,+          "typ": null,+          "max": null,+          "conditions": "VIC = 0, IO = 4 A; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification (±5 V), 25°C",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 80,+          "typ": 200,+          "max": null,+          "conditions": "VO = ±4 V, RL = 50 kΩ",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Large-signal differential voltage amplification (±5 V), full range",+          "symbol": "AVD",+          "kind": "electrical",+          "unit": "V/mV",+          "min": 50,+          "typ": null,+          "max": null,+          "conditions": "VO = ±4 V, RL = 50 kΩ; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio (±5 V), 25°C",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 75,+          "typ": 88,+          "max": null,+          "conditions": "VIC = −5 V to 2.7 V",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio (±5 V), full range",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 75,+          "typ": null,+          "max": null,+          "conditions": "VIC = −5 V to 2.7 V, VO = 0, RS = 50 Ω; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Supply-voltage rejection ratio (±5 V), 25°C",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 80,+          "typ": 95,+          "max": null,+          "conditions": "VDD± = ±2.2 V to ±8 V",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Supply-voltage rejection ratio (±5 V), full range",+          "symbol": "kSVR",+          "kind": "electrical",+          "unit": "dB",+          "min": 80,+          "typ": null,+          "max": null,+          "conditions": "VDD± = ±2.2 V to ±8 V, VIC = VDD/2, No load; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Supply current, four amplifiers (±5 V), 25°C",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 0.85,+          "max": 1,+          "conditions": "VO = 0, No load",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Supply current, four amplifiers (±5 V), full range",+          "symbol": "IDD",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VO = 0, No load; Full range (−40°C to 125°C)",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Slew rate at unity gain (VDD = 5 V table), 25°C",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/µs",+          "min": 0.35,+          "typ": 0.55,+          "max": null,+          "conditions": "VO = 0.5 V to 3.5 V, RL = 50 kΩ, CL = 100 pF",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Slew rate at unity gain (VDD = 5 V table), full range",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/µs",+          "min": 0.25,+          "typ": null,+          "max": null,+          "conditions": "VO = 0.5 V to 3.5 V, RL = 50 kΩ, CL = 100 pF; Full range (−40°C to 125°C)",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Slew rate at unity gain (±5 V table), 25°C",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/µs",+          "min": 0.35,+          "typ": 0.55,+          "max": null,+          "conditions": "VO = ±2 V, RL = 50 kΩ, CL = 100 pF",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Slew rate at unity gain (±5 V table), full range",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/µs",+          "min": 0.25,+          "typ": null,+          "max": null,+          "conditions": "VO = ±2 V, CL = 100 pF, RL = 50 kΩ; Full range (−40°C to 125°C)",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Input/output: Absolute maximum supply voltage, VDD+",+          "symbol": "VDD+",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 8,+          "conditions": "See Note 1",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Absolute maximum supply voltage, VDD−",+          "symbol": "VDD−",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -8,+          "typ": null,+          "max": null,+          "conditions": "See Note 1",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Differential input voltage",+          "symbol": "VID",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -16,+          "typ": null,+          "max": 16,+          "conditions": "See Note 2",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input current (each input)",+          "symbol": "II",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output current",+          "symbol": "IO",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Total current into VDD+",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Total current out of VDD−",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "D or PW package",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage, VDD± (recommended)",+          "symbol": "VDD±",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2.2,+          "typ": null,+          "max": 8,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature, TA (recommended)",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Continuous total dissipation, PW-14 package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 750,+          "conditions": "TA ≤ 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Continuous total dissipation, PW-14 package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 480,+          "conditions": "TA = 70°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Continuous total dissipation, PW-14 package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 389,+          "conditions": "TA = 85°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Continuous total dissipation, PW-14 package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "TA = 125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Derating factor, PW-14 package",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW/°C",+          "min": null,+          "typ": 6,+          "max": null,+          "conditions": "Above TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -255,4 +958,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}