tlc2264aqpwrq1: specified limits as data (metadata.characteristics, 58 rows from the datasheet)
2 files changed
+769−1
README.md+65@@ -32,6 +32,71 @@ TLC2264AQPWRQ1 from Texas Instruments, in a TSSOP-14. Pinout and pin description | Category | Amplifiers/Comparators | | Pins | 14 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input offset voltage (VDD = 5 V table), 25°C | VIO | | 300 | 950 | µV | | 9 |+| Input offset voltage (VDD = 5 V table), full range | VIO | | | 1500 | µV | Full range (−40°C to 125°C) | 9 |+| Common-mode input voltage range (VDD = 5 V table), 25°C | VICR | -0.3 | | 4.2 | V | RS = 50 Ω, /VIO/ ≤ 5 mV | 9 |+| Common-mode input voltage range (VDD = 5 V table), full range | VICR | 0 | | 3.5 | V | RS = 50 Ω, /VIO/ ≤ 5 mV; Full range (−40°C to 125°C) | 9 |+| High-level output voltage (VDD = 5 V table), 25°C | VOH | 4.85 | 4.94 | | V | IOH = −100 µA | 9 |+| High-level output voltage (VDD = 5 V table), full range | VOH | 4.82 | | | V | IOH = −100 µA; Full range (−40°C to 125°C) | 9 |+| High-level output voltage (VDD = 5 V table), 25°C | VOH | 4.7 | 4.85 | | V | IOH = −400 µA | 9 |+| High-level output voltage (VDD = 5 V table), full range | VOH | 4.5 | | | V | IOH = −400 µA; Full range (−40°C to 125°C) | 9 |+| Low-level output voltage (VDD = 5 V table), 25°C | VOL | | 0.09 | 0.15 | V | VIC = 2.5 V, IOL = 500 µA | 9 |+| Low-level output voltage (VDD = 5 V table), full range | VOL | | | 0.15 | V | VIC = 2.5 V, IOL = 500 µA; Full range (−40°C to 125°C) | 9 |+| Low-level output voltage (VDD = 5 V table), 25°C | VOL | | 0.7 | 1 | V | VIC = 2.5 V, IOL = 4 A | 9 |+| Low-level output voltage (VDD = 5 V table), full range | VOL | | | 1.2 | V | VIC = 2.5 V, IOL = 4 A; Full range (−40°C to 125°C) | 9 |+| Large-signal differential voltage amplification (VDD = 5 V table), 25°C | AVD | 80 | 170 | | V/mV | VIC = 2.5 V, VO = 1 V to 4 V, RL = 50 kΩ | 9 |+| Large-signal differential voltage amplification (VDD = 5 V table), full range | AVD | 50 | | | V/mV | VIC = 2.5 V, VO = 1 V to 4 V, RL = 50 kΩ; Full range (−40°C to 125°C) | 9 |+| Common-mode rejection ratio (VDD = 5 V table), 25°C | CMRR | 70 | 83 | | dB | VIC = 0 to 2.7 V, VO = 2.5 V | 9 |+| Common-mode rejection ratio (VDD = 5 V table), full range | CMRR | 70 | | | dB | VIC = 0 to 2.7 V, VO = 2.5 V, RS = 50 Ω; Full range (−40°C to 125°C) | 9 |+| Supply-voltage rejection ratio (VDD = 5 V table), 25°C | kSVR | 80 | 95 | | dB | VDD = 4.4 V to 16 V | 9 |+| Supply-voltage rejection ratio (VDD = 5 V table), full range | kSVR | 80 | | | dB | VDD = 4.4 V to 16 V, VIC = VDD/2, No load; Full range (−40°C to 125°C) | 9 |+| Supply current, four amplifiers (VDD = 5 V table), 25°C | IDD | | 0.8 | 1 | mA | VO = 2.5 V, No load | 9 |+| Supply current, four amplifiers (VDD = 5 V table), full range | IDD | | | 1 | mA | VO = 2.5 V, No load; Full range (−40°C to 125°C) | 9 |+| Common-mode input voltage range (VDD± = ±5 V table), 25°C | VICR | -5.3 | | 4.2 | V | RS = 50 Ω, /VIO/ ≤ 5 mV | 11 |+| Common-mode input voltage range (VDD± = ±5 V table), full range | VICR | -5 | | 3.5 | V | RS = 50 Ω, /VIO/ ≤ 5 mV; Full range (−40°C to 125°C) | 11 |+| Maximum positive peak output voltage (±5 V), 25°C | VOM+ | 4.85 | 4.94 | | V | IO = −100 µA | 11 |+| Maximum positive peak output voltage (±5 V), full range | VOM+ | 4.82 | | | V | IO = −100 µA; Full range (−40°C to 125°C) | 11 |+| Maximum positive peak output voltage (±5 V), 25°C | VOM+ | 4.7 | 4.85 | | V | IO = −400 µA | 11 |+| Maximum positive peak output voltage (±5 V), full range | VOM+ | 4.5 | | | V | IO = −400 µA; Full range (−40°C to 125°C) | 11 |+| Maximum negative peak output voltage (±5 V), 25°C | VOM− | -4.85 | -4.91 | | V | VIC = 0, IO = 500 µA | 11 |+| Maximum negative peak output voltage (±5 V), full range | VOM− | -4.85 | | | V | VIC = 0, IO = 500 µA; Full range (−40°C to 125°C) | 11 |+| Maximum negative peak output voltage (±5 V), 25°C | VOM− | -4 | -4.3 | | V | VIC = 0, IO = 4 A | 11 |+| Maximum negative peak output voltage (±5 V), full range | VOM− | -3.8 | | | V | VIC = 0, IO = 4 A; Full range (−40°C to 125°C) | 11 |+| Large-signal differential voltage amplification (±5 V), 25°C | AVD | 80 | 200 | | V/mV | VO = ±4 V, RL = 50 kΩ | 11 |+| Large-signal differential voltage amplification (±5 V), full range | AVD | 50 | | | V/mV | VO = ±4 V, RL = 50 kΩ; Full range (−40°C to 125°C) | 11 |+| Common-mode rejection ratio (±5 V), 25°C | CMRR | 75 | 88 | | dB | VIC = −5 V to 2.7 V | 11 |+| Common-mode rejection ratio (±5 V), full range | CMRR | 75 | | | dB | VIC = −5 V to 2.7 V, VO = 0, RS = 50 Ω; Full range (−40°C to 125°C) | 11 |+| Supply-voltage rejection ratio (±5 V), 25°C | kSVR | 80 | 95 | | dB | VDD± = ±2.2 V to ±8 V | 11 |+| Supply-voltage rejection ratio (±5 V), full range | kSVR | 80 | | | dB | VDD± = ±2.2 V to ±8 V, VIC = VDD/2, No load; Full range (−40°C to 125°C) | 11 |+| Supply current, four amplifiers (±5 V), 25°C | IDD | | 0.85 | 1 | mA | VO = 0, No load | 11 |+| Supply current, four amplifiers (±5 V), full range | IDD | | | 1 | mA | VO = 0, No load; Full range (−40°C to 125°C) | 11 |+| Slew rate at unity gain (VDD = 5 V table), 25°C | SR | 0.35 | 0.55 | | V/µs | VO = 0.5 V to 3.5 V, RL = 50 kΩ, CL = 100 pF | 10 |+| Slew rate at unity gain (VDD = 5 V table), full range | SR | 0.25 | | | V/µs | VO = 0.5 V to 3.5 V, RL = 50 kΩ, CL = 100 pF; Full range (−40°C to 125°C) | 10 |+| Slew rate at unity gain (±5 V table), 25°C | SR | 0.35 | 0.55 | | V/µs | VO = ±2 V, RL = 50 kΩ, CL = 100 pF | 12 |+| Slew rate at unity gain (±5 V table), full range | SR | 0.25 | | | V/µs | VO = ±2 V, CL = 100 pF, RL = 50 kΩ; Full range (−40°C to 125°C) | 12 |+| Input/output: Absolute maximum supply voltage, VDD+ | VDD+ | | | 8 | V | See Note 1 | 4 |+| Absolute maximum supply voltage, VDD− | VDD− | -8 | | | V | See Note 1 | 4 |+| Differential input voltage | VID | -16 | | 16 | V | See Note 2 | 4 |+| Input current (each input) | II | -5 | | 5 | mA | | 4 |+| Output current | IO | -50 | | 50 | mA | | 4 |+| Total current into VDD+ | | -50 | | 50 | mA | | 4 |+| Total current out of VDD− | | -50 | | 50 | mA | | 4 |+| Storage temperature range | Tstg | -65 | | 150 | °C | | 4 |+| Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds | | | | 260 | °C | D or PW package | 4 |+| Supply voltage, VDD± (recommended) | VDD± | 2.2 | | 8 | V | | 4 |+| Operating free-air temperature, TA (recommended) | TA | -40 | | 125 | °C | | 4 |+| Continuous total dissipation, PW-14 package | | | | 750 | mW | TA ≤ 25°C | 4 |+| Continuous total dissipation, PW-14 package | | | | 480 | mW | TA = 70°C | 4 |+| Continuous total dissipation, PW-14 package | | | | 389 | mW | TA = 85°C | 4 |+| Continuous total dissipation, PW-14 package | | | | 150 | mW | TA = 125°C | 4 |+| Derating factor, PW-14 package | | | 6 | | mW/°C | Above TA = 25°C | 4 |+ ## CAD (KiCad official) - Symbol: `TLC2264AQPWRQ1`
page.json+704−1@@ -214,6 +214,709 @@ "Package": "TSSOP-14", "Category": "Amplifiers/Comparators", "Pins": "14"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "bb43fda6e2682b1e",+ "rows": [+ {+ "name": "Input offset voltage (VDD = 5 V table), 25°C",+ "symbol": "VIO",+ "kind": "tolerance",+ "unit": "µV",+ "min": null,+ "typ": 300,+ "max": 950,+ "conditions": "",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage (VDD = 5 V table), full range",+ "symbol": "VIO",+ "kind": "tolerance",+ "unit": "µV",+ "min": null,+ "typ": null,+ "max": 1500,+ "conditions": "Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Common-mode input voltage range (VDD = 5 V table), 25°C",+ "symbol": "VICR",+ "kind": "electrical",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 4.2,+ "conditions": "RS = 50 Ω, |VIO| ≤ 5 mV",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Common-mode input voltage range (VDD = 5 V table), full range",+ "symbol": "VICR",+ "kind": "electrical",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 3.5,+ "conditions": "RS = 50 Ω, |VIO| ≤ 5 mV; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "High-level output voltage (VDD = 5 V table), 25°C",+ "symbol": "VOH",+ "kind": "electrical",+ "unit": "V",+ "min": 4.85,+ "typ": 4.94,+ "max": null,+ "conditions": "IOH = −100 µA",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "High-level output voltage (VDD = 5 V table), full range",+ "symbol": "VOH",+ "kind": "electrical",+ "unit": "V",+ "min": 4.82,+ "typ": null,+ "max": null,+ "conditions": "IOH = −100 µA; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "High-level output voltage (VDD = 5 V table), 25°C",+ "symbol": "VOH",+ "kind": "electrical",+ "unit": "V",+ "min": 4.7,+ "typ": 4.85,+ "max": null,+ "conditions": "IOH = −400 µA",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "High-level output voltage (VDD = 5 V table), full range",+ "symbol": "VOH",+ "kind": "electrical",+ "unit": "V",+ "min": 4.5,+ "typ": null,+ "max": null,+ "conditions": "IOH = −400 µA; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Low-level output voltage (VDD = 5 V table), 25°C",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": 0.09,+ "max": 0.15,+ "conditions": "VIC = 2.5 V, IOL = 500 µA",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Low-level output voltage (VDD = 5 V table), full range",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.15,+ "conditions": "VIC = 2.5 V, IOL = 500 µA; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Low-level output voltage (VDD = 5 V table), 25°C",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": 0.7,+ "max": 1,+ "conditions": "VIC = 2.5 V, IOL = 4 A",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Low-level output voltage (VDD = 5 V table), full range",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 1.2,+ "conditions": "VIC = 2.5 V, IOL = 4 A; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification (VDD = 5 V table), 25°C",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 80,+ "typ": 170,+ "max": null,+ "conditions": "VIC = 2.5 V, VO = 1 V to 4 V, RL = 50 kΩ",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification (VDD = 5 V table), full range",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 50,+ "typ": null,+ "max": null,+ "conditions": "VIC = 2.5 V, VO = 1 V to 4 V, RL = 50 kΩ; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio (VDD = 5 V table), 25°C",+ "symbol": "CMRR",+ "kind": "electrical",+ "unit": "dB",+ "min": 70,+ "typ": 83,+ "max": null,+ "conditions": "VIC = 0 to 2.7 V, VO = 2.5 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio (VDD = 5 V table), full range",+ "symbol": "CMRR",+ "kind": "electrical",+ "unit": "dB",+ "min": 70,+ "typ": null,+ "max": null,+ "conditions": "VIC = 0 to 2.7 V, VO = 2.5 V, RS = 50 Ω; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Supply-voltage rejection ratio (VDD = 5 V table), 25°C",+ "symbol": "kSVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 80,+ "typ": 95,+ "max": null,+ "conditions": "VDD = 4.4 V to 16 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Supply-voltage rejection ratio (VDD = 5 V table), full range",+ "symbol": "kSVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 80,+ "typ": null,+ "max": null,+ "conditions": "VDD = 4.4 V to 16 V, VIC = VDD/2, No load; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Supply current, four amplifiers (VDD = 5 V table), 25°C",+ "symbol": "IDD",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 0.8,+ "max": 1,+ "conditions": "VO = 2.5 V, No load",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Supply current, four amplifiers (VDD = 5 V table), full range",+ "symbol": "IDD",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "VO = 2.5 V, No load; Full range (−40°C to 125°C)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Common-mode input voltage range (VDD± = ±5 V table), 25°C",+ "symbol": "VICR",+ "kind": "electrical",+ "unit": "V",+ "min": -5.3,+ "typ": null,+ "max": 4.2,+ "conditions": "RS = 50 Ω, |VIO| ≤ 5 mV",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Common-mode input voltage range (VDD± = ±5 V table), full range",+ "symbol": "VICR",+ "kind": "electrical",+ "unit": "V",+ "min": -5,+ "typ": null,+ "max": 3.5,+ "conditions": "RS = 50 Ω, |VIO| ≤ 5 mV; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Maximum positive peak output voltage (±5 V), 25°C",+ "symbol": "VOM+",+ "kind": "electrical",+ "unit": "V",+ "min": 4.85,+ "typ": 4.94,+ "max": null,+ "conditions": "IO = −100 µA",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Maximum positive peak output voltage (±5 V), full range",+ "symbol": "VOM+",+ "kind": "electrical",+ "unit": "V",+ "min": 4.82,+ "typ": null,+ "max": null,+ "conditions": "IO = −100 µA; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Maximum positive peak output voltage (±5 V), 25°C",+ "symbol": "VOM+",+ "kind": "electrical",+ "unit": "V",+ "min": 4.7,+ "typ": 4.85,+ "max": null,+ "conditions": "IO = −400 µA",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Maximum positive peak output voltage (±5 V), full range",+ "symbol": "VOM+",+ "kind": "electrical",+ "unit": "V",+ "min": 4.5,+ "typ": null,+ "max": null,+ "conditions": "IO = −400 µA; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Maximum negative peak output voltage (±5 V), 25°C",+ "symbol": "VOM−",+ "kind": "electrical",+ "unit": "V",+ "min": -4.85,+ "typ": -4.91,+ "max": null,+ "conditions": "VIC = 0, IO = 500 µA",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Maximum negative peak output voltage (±5 V), full range",+ "symbol": "VOM−",+ "kind": "electrical",+ "unit": "V",+ "min": -4.85,+ "typ": null,+ "max": null,+ "conditions": "VIC = 0, IO = 500 µA; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Maximum negative peak output voltage (±5 V), 25°C",+ "symbol": "VOM−",+ "kind": "electrical",+ "unit": "V",+ "min": -4,+ "typ": -4.3,+ "max": null,+ "conditions": "VIC = 0, IO = 4 A",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Maximum negative peak output voltage (±5 V), full range",+ "symbol": "VOM−",+ "kind": "electrical",+ "unit": "V",+ "min": -3.8,+ "typ": null,+ "max": null,+ "conditions": "VIC = 0, IO = 4 A; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification (±5 V), 25°C",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 80,+ "typ": 200,+ "max": null,+ "conditions": "VO = ±4 V, RL = 50 kΩ",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification (±5 V), full range",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 50,+ "typ": null,+ "max": null,+ "conditions": "VO = ±4 V, RL = 50 kΩ; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio (±5 V), 25°C",+ "symbol": "CMRR",+ "kind": "electrical",+ "unit": "dB",+ "min": 75,+ "typ": 88,+ "max": null,+ "conditions": "VIC = −5 V to 2.7 V",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio (±5 V), full range",+ "symbol": "CMRR",+ "kind": "electrical",+ "unit": "dB",+ "min": 75,+ "typ": null,+ "max": null,+ "conditions": "VIC = −5 V to 2.7 V, VO = 0, RS = 50 Ω; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Supply-voltage rejection ratio (±5 V), 25°C",+ "symbol": "kSVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 80,+ "typ": 95,+ "max": null,+ "conditions": "VDD± = ±2.2 V to ±8 V",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Supply-voltage rejection ratio (±5 V), full range",+ "symbol": "kSVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 80,+ "typ": null,+ "max": null,+ "conditions": "VDD± = ±2.2 V to ±8 V, VIC = VDD/2, No load; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Supply current, four amplifiers (±5 V), 25°C",+ "symbol": "IDD",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 0.85,+ "max": 1,+ "conditions": "VO = 0, No load",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Supply current, four amplifiers (±5 V), full range",+ "symbol": "IDD",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "VO = 0, No load; Full range (−40°C to 125°C)",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Slew rate at unity gain (VDD = 5 V table), 25°C",+ "symbol": "SR",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 0.35,+ "typ": 0.55,+ "max": null,+ "conditions": "VO = 0.5 V to 3.5 V, RL = 50 kΩ, CL = 100 pF",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Slew rate at unity gain (VDD = 5 V table), full range",+ "symbol": "SR",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 0.25,+ "typ": null,+ "max": null,+ "conditions": "VO = 0.5 V to 3.5 V, RL = 50 kΩ, CL = 100 pF; Full range (−40°C to 125°C)",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Slew rate at unity gain (±5 V table), 25°C",+ "symbol": "SR",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 0.35,+ "typ": 0.55,+ "max": null,+ "conditions": "VO = ±2 V, RL = 50 kΩ, CL = 100 pF",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Slew rate at unity gain (±5 V table), full range",+ "symbol": "SR",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 0.25,+ "typ": null,+ "max": null,+ "conditions": "VO = ±2 V, CL = 100 pF, RL = 50 kΩ; Full range (−40°C to 125°C)",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Input/output: Absolute maximum supply voltage, VDD+",+ "symbol": "VDD+",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "See Note 1",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Absolute maximum supply voltage, VDD−",+ "symbol": "VDD−",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -8,+ "typ": null,+ "max": null,+ "conditions": "See Note 1",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Differential input voltage",+ "symbol": "VID",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -16,+ "typ": null,+ "max": 16,+ "conditions": "See Note 2",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input current (each input)",+ "symbol": "II",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Output current",+ "symbol": "IO",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -50,+ "typ": null,+ "max": 50,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Total current into VDD+",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -50,+ "typ": null,+ "max": 50,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Total current out of VDD−",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -50,+ "typ": null,+ "max": 50,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "D or PW package",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage, VDD± (recommended)",+ "symbol": "VDD±",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 2.2,+ "typ": null,+ "max": 8,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Operating free-air temperature, TA (recommended)",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Continuous total dissipation, PW-14 package",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 750,+ "conditions": "TA ≤ 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Continuous total dissipation, PW-14 package",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 480,+ "conditions": "TA = 70°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Continuous total dissipation, PW-14 package",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 389,+ "conditions": "TA = 85°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Continuous total dissipation, PW-14 package",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "TA = 125°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Derating factor, PW-14 package",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW/°C",+ "min": null,+ "typ": 6,+ "max": null,+ "conditions": "Above TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -255,4 +958,4 @@ "visibility": { "public": true }-}+}