← Commit history
tlc2201ip: specified limits as data (metadata.characteristics, 60 rows from the datasheet)
2 files changed
+795−1
README.md+67@@ -26,6 +26,73 @@ TLC2201IP from Texas Instruments, in a PDIP-8. Pinout and pin descriptions extra | Category | Amplifiers/Comparators | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input offset voltage | VIO | | 100 | 500 | µV | VDD± = ±5 V; TA = 25°C | 18 |+| Input offset voltage | VIO | | | 650 | µV | VDD± = ±5 V; TA = full range (−40°C to 85°C) | 18 |+| Input offset voltage long-term drift | | | 0.001 | 0.005 | µV/mo | VIC = 0, RS = 50 Ω; TA = 25°C | 18 |+| Input offset current | IIO | | 0.5 | 60 | pA | VIC = 0, RS = 50 Ω; TA = 25°C | 18 |+| Input offset current | IIO | | | 150 | pA | VDD± = ±5 V; TA = full range (−40°C to 85°C) | 18 |+| Input bias current | IIB | | 1 | 60 | pA | VDD± = ±5 V; TA = 25°C | 18 |+| Input bias current | IIB | | | 150 | pA | VDD± = ±5 V; TA = full range (−40°C to 85°C) | 18 |+| Common-mode input voltage range | VICR | -5 | | 2.7 | V | RS = 50 Ω; TA = full range (−40°C to 85°C) | 18 |+| Maximum positive peak output voltage swing | VOM+ | 4.7 | 4.8 | | V | RL = 10 kΩ; TA = 25°C | 18 |+| Maximum positive peak output voltage swing | VOM+ | 4.7 | | | V | RL = 10 kΩ; TA = full range (−40°C to 85°C) | 18 |+| Maximum negative peak output voltage swing | VOM− | -4.7 | -4.9 | | V | RL = 10 kΩ; TA = 25°C | 18 |+| Maximum negative peak output voltage swing | VOM− | -4.7 | | | V | RL = 10 kΩ; TA = full range (−40°C to 85°C) | 18 |+| Large-signal differential voltage amplification | AVD | 400 | 560 | | V/mV | VO = ±4 V, RL = 500 kΩ; TA = 25°C | 18 |+| Large-signal differential voltage amplification | AVD | 250 | | | V/mV | VO = ±4 V, RL = 500 kΩ; TA = full range (−40°C to 85°C) | 18 |+| Large-signal differential voltage amplification | AVD | 90 | 100 | | V/mV | VO = ±4 V, RL = 10 kΩ; TA = 25°C | 18 |+| Large-signal differential voltage amplification | AVD | 65 | | | V/mV | VO = ±4 V, RL = 10 kΩ; TA = full range (−40°C to 85°C) | 18 |+| Common-mode rejection ratio | CMRR | 90 | 115 | | dB | VIC = VICRmin, VO = 0, RS = 50 Ω; TA = 25°C | 18 |+| Common-mode rejection ratio | CMRR | 85 | | | dB | VIC = VICRmin, VO = 0, RS = 50 Ω; TA = full range (−40°C to 85°C) | 18 |+| Supply voltage rejection ratio (ΔVDD±/ΔVIO) | kSVR | 90 | 110 | | dB | VDD± = ±2.3 V to ±8 V; TA = 25°C | 18 |+| Supply voltage rejection ratio (ΔVDD±/ΔVIO) | kSVR | 85 | | | dB | VDD± = ±2.3 V to ±8 V; TA = full range (−40°C to 85°C) | 18 |+| Supply current | IDD | | 1.1 | 1.5 | mA | VO = 0, no load; TA = 25°C | 18 |+| Supply current | IDD | | | 1.5 | mA | VO = 0, no load; TA = full range (−40°C to 85°C) | 18 |+| Slew rate at unity gain | SR | 2 | 2.7 | | V/µs | VO = ±2.3 V, RL = 10 kΩ; TA = 25°C | 20 |+| Slew rate at unity gain | SR | 1.4 | | | V/µs | VO = ±2.3 V, CL = 100 pF, RL = 10 kΩ; TA = full range (−40°C to 85°C) | 20 |+| Input offset voltage | VIO | | 100 | 500 | µV | VDD = 5 V; TA = 25°C | 21 |+| Input offset voltage | VIO | | | 650 | µV | VDD = 5 V; TA = full range (−40°C to 85°C) | 21 |+| Input offset voltage long-term drift | | | 0.001 | 0.005 | µV/mo | VDD = 5 V, VIC = 0, RS = 50 Ω; TA = 25°C | 21 |+| Input offset current | IIO | | 0.5 | 60 | pA | VDD = 5 V, VIC = 0, RS = 50 Ω; TA = 25°C | 21 |+| Input offset current | IIO | | | 150 | pA | VDD = 5 V; TA = full range (−40°C to 85°C) | 21 |+| Input bias current | IIB | | 1 | 60 | pA | VDD = 5 V; TA = 25°C | 21 |+| Input bias current | IIB | | | 150 | pA | VDD = 5 V; TA = full range (−40°C to 85°C) | 21 |+| Common-mode input voltage range | VICR | 0 | | 2.7 | V | VDD = 5 V, RS = 50 Ω; TA = full range (−40°C to 85°C) | 21 |+| Maximum high-level output voltage | VOH | 4.7 | 4.8 | | V | VDD = 5 V, RL = 10 kΩ; TA = 25°C | 21 |+| Maximum high-level output voltage | VOH | 4.7 | | | V | VDD = 5 V, RL = 10 kΩ; TA = full range (−40°C to 85°C) | 21 |+| Maximum low-level output voltage | VOL | | 0 | 50 | mV | VDD = 5 V, IO = 0; TA = 25°C | 21 |+| Maximum low-level output voltage | VOL | | | 50 | mV | VDD = 5 V, IO = 0; TA = full range (−40°C to 85°C) | 21 |+| Large-signal differential voltage amplification | AVD | 150 | 315 | | V/mV | VDD = 5 V, VO = 1 V to 4 V, RL = 500 kΩ; TA = 25°C | 21 |+| Large-signal differential voltage amplification | AVD | 100 | | | V/mV | VDD = 5 V, VO = 1 V to 4 V, RL = 500 kΩ; TA = full range (−40°C to 85°C) | 21 |+| Large-signal differential voltage amplification | AVD | 25 | 55 | | V/mV | VDD = 5 V, VO = 1 V to 4 V, RL = 10 kΩ; TA = 25°C | 21 |+| Large-signal differential voltage amplification | AVD | 15 | | | V/mV | VDD = 5 V, VO = 1 V to 4 V, RL = 10 kΩ; TA = full range (−40°C to 85°C) | 21 |+| Common-mode rejection ratio | CMRR | 90 | 110 | | dB | VDD = 5 V, VIC = VICRmin, VO = 0, RS = 50 Ω; TA = 25°C | 21 |+| Common-mode rejection ratio | CMRR | 85 | | | dB | VDD = 5 V, VIC = VICRmin, VO = 0, RS = 50 Ω; TA = full range (−40°C to 85°C) | 21 |+| Supply voltage rejection ratio (ΔVDD±/ΔVIO) | kSVR | 90 | 110 | | dB | VDD = 4.6 V to 16 V; TA = 25°C | 21 |+| Supply voltage rejection ratio (ΔVDD±/ΔVIO) | kSVR | 85 | | | dB | VDD = 4.6 V to 16 V; TA = full range (−40°C to 85°C) | 21 |+| Supply current | IDD | | 1 | 1.5 | mA | VDD = 5 V, VO = 2.5 V, no load; TA = 25°C | 21 |+| Supply current | IDD | | | 1.5 | mA | VDD = 5 V, VO = 2.5 V, no load; TA = full range (−40°C to 85°C) | 21 |+| Slew rate at unity gain | SR | 1.8 | 2.5 | | V/µs | VDD = 5 V, VO = 0.5 V to 2.5 V, RL = 10 kΩ, CL = 100 pF; TA = 25°C | 21 |+| Slew rate at unity gain | SR | 1.2 | | | V/µs | VDD = 5 V, VO = 0.5 V to 2.5 V, RL = 10 kΩ, CL = 100 pF; TA = full range (−40°C to 85°C) | 21 |+| Supply voltage | VDD± | 2.3 | | 8 | V | I suffix | 7 |+| Operating free-air temperature | TA | -40 | | 85 | °C | I suffix | 7 |+| Supply voltage, VDD+ | VDD+ | | | 8 | V | All voltages referenced to midpoint of VDD+ and VDD− | 7 |+| Supply voltage, VDD− | VDD− | -8 | | | V | All voltages referenced to midpoint of VDD+ and VDD− | 7 |+| Differential input voltage | VID | -16 | | 16 | V | Differential voltage at IN+ with respect to IN− | 7 |+| Input voltage (any input) | VI | -8 | | 8 | V | | 7 |+| Input current (each input) | II | -5 | | 5 | mA | | 7 |+| Output current (each output) | IO | -50 | | 50 | mA | | 7 |+| Storage temperature range | Tstg | -65 | | 150 | °C | | 7 |+| Power rating, P package | | | | 1000 | mW | TA ≤ 25°C; P package (dissipation rating table) | 7 |+| Derating factor above TA = 25°C, P package | | | 8 | | mW/°C | P package (dissipation rating table) | 7 |+| Power rating, P package | | | | 520 | mW | TA = 85°C; P package (dissipation rating table) | 7 |+ ## CAD (KiCad official) - Symbol: `TLC2201IP`
page.json+728−1@@ -180,6 +180,733 @@ "Package": "PDIP-8", "Category": "Amplifiers/Comparators", "Pins": "8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "8125cf3cb9306abc",+ "rows": [+ {+ "name": "Input offset voltage",+ "symbol": "VIO",+ "kind": "electrical",+ "unit": "µV",+ "min": null,+ "typ": 100,+ "max": 500,+ "conditions": "VDD± = ±5 V; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage",+ "symbol": "VIO",+ "kind": "electrical",+ "unit": "µV",+ "min": null,+ "typ": null,+ "max": 650,+ "conditions": "VDD± = ±5 V; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage long-term drift",+ "symbol": "",+ "kind": "electrical",+ "unit": "µV/mo",+ "min": null,+ "typ": 0.001,+ "max": 0.005,+ "conditions": "VIC = 0, RS = 50 Ω; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "IIO",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 0.5,+ "max": 60,+ "conditions": "VIC = 0, RS = 50 Ω; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "IIO",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "VDD± = ±5 V; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "IIB",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 1,+ "max": 60,+ "conditions": "VDD± = ±5 V; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "IIB",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "VDD± = ±5 V; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Common-mode input voltage range",+ "symbol": "VICR",+ "kind": "electrical",+ "unit": "V",+ "min": -5,+ "typ": null,+ "max": 2.7,+ "conditions": "RS = 50 Ω; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Maximum positive peak output voltage swing",+ "symbol": "VOM+",+ "kind": "electrical",+ "unit": "V",+ "min": 4.7,+ "typ": 4.8,+ "max": null,+ "conditions": "RL = 10 kΩ; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Maximum positive peak output voltage swing",+ "symbol": "VOM+",+ "kind": "electrical",+ "unit": "V",+ "min": 4.7,+ "typ": null,+ "max": null,+ "conditions": "RL = 10 kΩ; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Maximum negative peak output voltage swing",+ "symbol": "VOM−",+ "kind": "electrical",+ "unit": "V",+ "min": -4.7,+ "typ": -4.9,+ "max": null,+ "conditions": "RL = 10 kΩ; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Maximum negative peak output voltage swing",+ "symbol": "VOM−",+ "kind": "electrical",+ "unit": "V",+ "min": -4.7,+ "typ": null,+ "max": null,+ "conditions": "RL = 10 kΩ; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 400,+ "typ": 560,+ "max": null,+ "conditions": "VO = ±4 V, RL = 500 kΩ; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 250,+ "typ": null,+ "max": null,+ "conditions": "VO = ±4 V, RL = 500 kΩ; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 90,+ "typ": 100,+ "max": null,+ "conditions": "VO = ±4 V, RL = 10 kΩ; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 65,+ "typ": null,+ "max": null,+ "conditions": "VO = ±4 V, RL = 10 kΩ; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMRR",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 115,+ "max": null,+ "conditions": "VIC = VICRmin, VO = 0, RS = 50 Ω; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMRR",+ "kind": "electrical",+ "unit": "dB",+ "min": 85,+ "typ": null,+ "max": null,+ "conditions": "VIC = VICRmin, VO = 0, RS = 50 Ω; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage rejection ratio (ΔVDD±/ΔVIO)",+ "symbol": "kSVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 110,+ "max": null,+ "conditions": "VDD± = ±2.3 V to ±8 V; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage rejection ratio (ΔVDD±/ΔVIO)",+ "symbol": "kSVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 85,+ "typ": null,+ "max": null,+ "conditions": "VDD± = ±2.3 V to ±8 V; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Supply current",+ "symbol": "IDD",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 1.1,+ "max": 1.5,+ "conditions": "VO = 0, no load; TA = 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Supply current",+ "symbol": "IDD",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "VO = 0, no load; TA = full range (−40°C to 85°C)",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Slew rate at unity gain",+ "symbol": "SR",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 2,+ "typ": 2.7,+ "max": null,+ "conditions": "VO = ±2.3 V, RL = 10 kΩ; TA = 25°C",+ "source_page": 20,+ "source": "datasheet"+ },+ {+ "name": "Slew rate at unity gain",+ "symbol": "SR",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 1.4,+ "typ": null,+ "max": null,+ "conditions": "VO = ±2.3 V, CL = 100 pF, RL = 10 kΩ; TA = full range (−40°C to 85°C)",+ "source_page": 20,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage",+ "symbol": "VIO",+ "kind": "electrical",+ "unit": "µV",+ "min": null,+ "typ": 100,+ "max": 500,+ "conditions": "VDD = 5 V; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage",+ "symbol": "VIO",+ "kind": "electrical",+ "unit": "µV",+ "min": null,+ "typ": null,+ "max": 650,+ "conditions": "VDD = 5 V; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage long-term drift",+ "symbol": "",+ "kind": "electrical",+ "unit": "µV/mo",+ "min": null,+ "typ": 0.001,+ "max": 0.005,+ "conditions": "VDD = 5 V, VIC = 0, RS = 50 Ω; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "IIO",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 0.5,+ "max": 60,+ "conditions": "VDD = 5 V, VIC = 0, RS = 50 Ω; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "IIO",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "VDD = 5 V; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "IIB",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 1,+ "max": 60,+ "conditions": "VDD = 5 V; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "IIB",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "VDD = 5 V; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Common-mode input voltage range",+ "symbol": "VICR",+ "kind": "electrical",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 2.7,+ "conditions": "VDD = 5 V, RS = 50 Ω; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Maximum high-level output voltage",+ "symbol": "VOH",+ "kind": "electrical",+ "unit": "V",+ "min": 4.7,+ "typ": 4.8,+ "max": null,+ "conditions": "VDD = 5 V, RL = 10 kΩ; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Maximum high-level output voltage",+ "symbol": "VOH",+ "kind": "electrical",+ "unit": "V",+ "min": 4.7,+ "typ": null,+ "max": null,+ "conditions": "VDD = 5 V, RL = 10 kΩ; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Maximum low-level output voltage",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 0,+ "max": 50,+ "conditions": "VDD = 5 V, IO = 0; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Maximum low-level output voltage",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "VDD = 5 V, IO = 0; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 150,+ "typ": 315,+ "max": null,+ "conditions": "VDD = 5 V, VO = 1 V to 4 V, RL = 500 kΩ; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 100,+ "typ": null,+ "max": null,+ "conditions": "VDD = 5 V, VO = 1 V to 4 V, RL = 500 kΩ; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 25,+ "typ": 55,+ "max": null,+ "conditions": "VDD = 5 V, VO = 1 V to 4 V, RL = 10 kΩ; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Large-signal differential voltage amplification",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "V/mV",+ "min": 15,+ "typ": null,+ "max": null,+ "conditions": "VDD = 5 V, VO = 1 V to 4 V, RL = 10 kΩ; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMRR",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 110,+ "max": null,+ "conditions": "VDD = 5 V, VIC = VICRmin, VO = 0, RS = 50 Ω; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMRR",+ "kind": "electrical",+ "unit": "dB",+ "min": 85,+ "typ": null,+ "max": null,+ "conditions": "VDD = 5 V, VIC = VICRmin, VO = 0, RS = 50 Ω; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage rejection ratio (ΔVDD±/ΔVIO)",+ "symbol": "kSVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 110,+ "max": null,+ "conditions": "VDD = 4.6 V to 16 V; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage rejection ratio (ΔVDD±/ΔVIO)",+ "symbol": "kSVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 85,+ "typ": null,+ "max": null,+ "conditions": "VDD = 4.6 V to 16 V; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Supply current",+ "symbol": "IDD",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 1,+ "max": 1.5,+ "conditions": "VDD = 5 V, VO = 2.5 V, no load; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Supply current",+ "symbol": "IDD",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "VDD = 5 V, VO = 2.5 V, no load; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Slew rate at unity gain",+ "symbol": "SR",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 1.8,+ "typ": 2.5,+ "max": null,+ "conditions": "VDD = 5 V, VO = 0.5 V to 2.5 V, RL = 10 kΩ, CL = 100 pF; TA = 25°C",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Slew rate at unity gain",+ "symbol": "SR",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 1.2,+ "typ": null,+ "max": null,+ "conditions": "VDD = 5 V, VO = 0.5 V to 2.5 V, RL = 10 kΩ, CL = 100 pF; TA = full range (−40°C to 85°C)",+ "source_page": 21,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage",+ "symbol": "VDD±",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 2.3,+ "typ": null,+ "max": 8,+ "conditions": "I suffix",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Operating free-air temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "I suffix",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage, VDD+",+ "symbol": "VDD+",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "All voltages referenced to midpoint of VDD+ and VDD−",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage, VDD−",+ "symbol": "VDD−",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -8,+ "typ": null,+ "max": null,+ "conditions": "All voltages referenced to midpoint of VDD+ and VDD−",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Differential input voltage",+ "symbol": "VID",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -16,+ "typ": null,+ "max": 16,+ "conditions": "Differential voltage at IN+ with respect to IN−",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Input voltage (any input)",+ "symbol": "VI",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -8,+ "typ": null,+ "max": 8,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Input current (each input)",+ "symbol": "II",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Output current (each output)",+ "symbol": "IO",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -50,+ "typ": null,+ "max": 50,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Power rating, P package",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 1000,+ "conditions": "TA ≤ 25°C; P package (dissipation rating table)",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Derating factor above TA = 25°C, P package",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW/°C",+ "min": null,+ "typ": 8,+ "max": null,+ "conditions": "P package (dissipation rating table)",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Power rating, P package",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 520,+ "conditions": "TA = 85°C; P package (dissipation rating table)",+ "source_page": 7,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -221,4 +948,4 @@ "visibility": { "public": true }-}+}