← Commit history
page.json+7−4@@ -50,7 +50,7 @@ "number": "4", "name": "RXD", "type": "output",- "description": "CAN receive data output to the local protocol controller. Reports the bus state (low = dominant, high = recessive). Tri-state when powered off. IOL/IOH \u00b12 mA typ, 8 mA absolute max."+ "description": "CAN receive data output to the local protocol controller. Reports the bus state (low = dominant, high = recessive). Tri-state when powered off. IOL/IOH ±2 mA typ, 8 mA absolute max." }, { "number": "5",@@ -62,13 +62,13 @@ "number": "6", "name": "CANL", "type": "bidirectional",- "description": "Low-level CAN differential bus input/output. Withstands \u00b158 V bus faults and ISO 7637 transients. Pair with CANH through the twisted-pair bus with termination."+ "description": "Low-level CAN differential bus input/output. Withstands ±58 V bus faults and ISO 7637 transients. Pair with CANH through the twisted-pair bus with termination." }, { "number": "7", "name": "CANH", "type": "bidirectional",- "description": "High-level CAN differential bus input/output. Withstands \u00b158 V bus faults and ISO 7637 transients. Pair with CANL through the twisted-pair bus with termination."+ "description": "High-level CAN differential bus input/output. Withstands ±58 V bus faults and ISO 7637 transients. Pair with CANL through the twisted-pair bus with termination." }, { "number": "8",@@ -160,5 +160,8 @@ "docs/tcan1044vdrq1-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }