← Commit history

Set visibility: public

Ray ·41eef8ad10 · ·parent ee384e9
1 file changed +10−7
page.json+10−7
@@ -56,7 +56,7 @@         "number": "4",         "name": "RXD",         "type": "tri_state",-        "description": "CAN receive data output (low for dominant, high for recessive) with tri-state capability and common-mode input range \u00b130V in normal mode."+        "description": "CAN receive data output (low for dominant, high for recessive) with tri-state capability and common-mode input range ±30V in normal mode."       },       {         "number": "5",@@ -68,7 +68,7 @@         "number": "6",         "name": "EN",         "type": "input",-        "description": "Enable input for mode control with integrated pull-down and logic thresholds at 0.7\u00d7VIO (high) and 0.3\u00d7VIO (low)."+        "description": "Enable input for mode control with integrated pull-down and logic thresholds at 0.7×VIO (high) and 0.3×VIO (low)."       },       {         "number": "7",@@ -86,7 +86,7 @@         "number": "9",         "name": "WAKE",         "type": "input",-        "description": "High voltage wake input terminal for local wake-up via voltage transitions, supporting maximum \u00b158V."+        "description": "High voltage wake input terminal for local wake-up via voltage transitions, supporting maximum ±58V."       },       {         "number": "10",@@ -104,19 +104,19 @@         "number": "12",         "name": "CANL",         "type": "bidirectional",-        "description": "Low-level CAN bus input/output line with \u00b158V bus fault protection and \u00b130V common-mode input range."+        "description": "Low-level CAN bus input/output line with ±58V bus fault protection and ±30V common-mode input range."       },       {         "number": "13",         "name": "CANH",         "type": "bidirectional",-        "description": "High-level CAN bus input/output line with \u00b158V bus fault protection and \u00b130V common-mode input range."+        "description": "High-level CAN bus input/output line with ±58V bus fault protection and ±30V common-mode input range."       },       {         "number": "14",         "name": "nSTB",         "type": "input",-        "description": "Standby mode input for mode control with integrated pull-down and logic thresholds at 0.7\u00d7VIO (high) and 0.3\u00d7VIO (low)."+        "description": "Standby mode input for mode control with integrated pull-down and logic thresholds at 0.7×VIO (high) and 0.3×VIO (low)."       }     ],     "provenance": {@@ -194,5 +194,8 @@     "docs/tcan1043gdrq1-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file