← Commit history

Set visibility: public

Ray ·33ca13021f ·1mo ago ·parent 06f02cb
1 file changed +8−5
page.json+8−5
@@ -50,25 +50,25 @@         "number": "4",         "name": "RXD",         "type": "output",-        "description": "CAN receive data output to the local protocol controller. LOW indicates a dominant bus state, HIGH indicates a recessive bus state. Output high level is referenced to V_IO on 'V' suffix devices. Drive capability \u00b12 mA (absolute max \u00b18 mA)."+        "description": "CAN receive data output to the local protocol controller. LOW indicates a dominant bus state, HIGH indicates a recessive bus state. Output high level is referenced to V_IO on 'V' suffix devices. Drive capability ±2 mA (absolute max ±8 mA)."       },       {         "number": "5",         "name": "VIO",         "type": "power_in",-        "description": "I/O level-shifting supply voltage (3 V to 5.5 V) used to match the logic-side supply of the host MCU. Sets the TXD/STB input thresholds and the RXD output high level. Required only on 'V' suffix devices; supports undervoltage-protected mode (UV_VIO \u2248 1.3-2.75 V)."+        "description": "I/O level-shifting supply voltage (3 V to 5.5 V) used to match the logic-side supply of the host MCU. Sets the TXD/STB input thresholds and the RXD output high level. Required only on 'V' suffix devices; supports undervoltage-protected mode (UV_VIO ≈ 1.3-2.75 V)."       },       {         "number": "6",         "name": "CANL",         "type": "bidirectional",-        "description": "Low-side CAN bus I/O line. Differential bus terminal paired with CANH. Fault-protected to \u00b170 V on the 'H' variants, common-mode input range \u00b130 V. Tolerates up to \u00b170 V differential (V_DIFF)."+        "description": "Low-side CAN bus I/O line. Differential bus terminal paired with CANH. Fault-protected to ±70 V on the 'H' variants, common-mode input range ±30 V. Tolerates up to ±70 V differential (V_DIFF)."       },       {         "number": "7",         "name": "CANH",         "type": "bidirectional",-        "description": "High-side CAN bus I/O line. Differential bus terminal paired with CANL. Fault-protected to \u00b170 V on the 'H' variants, common-mode input range \u00b130 V."+        "description": "High-side CAN bus I/O line. Differential bus terminal paired with CANL. Fault-protected to ±70 V on the 'H' variants, common-mode input range ±30 V."       },       {         "number": "8",@@ -152,5 +152,8 @@     "docs/tcan1042hvdrq1-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file