← Commit history
page.json+7−4@@ -38,19 +38,19 @@ "number": "2", "name": "GND", "type": "power_in",- "description": "Ground reference for the device. Also serves as the case position for \u03b8JC thermal measurement and should be tied to a solid ground plane with thermal vias for heat dissipation."+ "description": "Ground reference for the device. Also serves as the case position for θJC thermal measurement and should be tied to a solid ground plane with thermal vias for heat dissipation." }, { "number": "3", "name": "FB", "type": "input",- "description": "Output feedback pin. Connect to the center tap of an external resistor divider from VOUT to set the output voltage per Vout = 0.6V \u00d7 (1 + R1/R2). Internal reference is 0.6V \u00b12%."+ "description": "Output feedback pin. Connect to the center tap of an external resistor divider from VOUT to set the output voltage per Vout = 0.6V × (1 + R1/R2). Internal reference is 0.6V ±2%." }, { "number": "4", "name": "EN", "type": "input",- "description": "Enable control input. Pull high (VENH \u2265 1.5V) to turn the regulator on; pull low (VENL \u2264 0.4V) to shut it down. Do not float. Absolute maximum voltage is VIN + 0.3V."+ "description": "Enable control input. Pull high (VENH ≥ 1.5V) to turn the regulator on; pull low (VENL ≤ 0.4V) to shut it down. Do not float. Absolute maximum voltage is VIN + 0.3V." }, { "number": "5",@@ -126,5 +126,8 @@ "docs/sy8201abc-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }