← Commit history
page.json+7−4@@ -50,7 +50,7 @@ "number": "3", "name": "NRESET", "type": "input",- "description": "Active-low reset input with internal 50 k\u03a9 pull-up. Drive low to reset the transceiver."+ "description": "Active-low reset input with internal 50 kΩ pull-up. Drive low to reset the transceiver." }, { "number": "4",@@ -98,7 +98,7 @@ "number": "11", "name": "VBAT_IO", "type": "power_in",- "description": "Supply for the digital I/O interface, 1.8 V to 3.7 V. Must be \u2264 VBAT."+ "description": "Supply for the digital I/O interface, 1.8 V to 3.7 V. Must be ≤ VBAT." }, { "number": "12",@@ -122,7 +122,7 @@ "number": "15", "name": "VBAT", "type": "power_in",- "description": "Main supply for the RFIC, 1.8 V to 3.7 V. Must be \u2265 VBAT_IO."+ "description": "Main supply for the RFIC, 1.8 V to 3.7 V. Must be ≥ VBAT_IO." }, { "number": "16",@@ -246,5 +246,8 @@ "docs/sx1280imltrt-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }