← Commit history

stp75nf75: specified limits as data (metadata.characteristics, 26 rows from the datasheet)

Ray ·24e934b729 · ·parent 04a7b6e
2 files changed +352
README.md+33
@@ -21,6 +21,39 @@ STP75NF75 from STMicroelectronics, in a TO-220. Pinout and pin descriptions extr | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Drain-source voltage | VDS |  |  | 75 | V | VGS = 0 | 3 |+| Drain-gate voltage | VDGR |  |  | 75 | V | RGS = 20KΩ | 3 |+| Gate-source voltage | VGS | -20 |  | 20 | V |  | 3 |+| Drain current (continuous) | ID |  |  | 80 | A | TC = 25°C | 3 |+| Drain current (continuous) | ID |  |  | 70 | A | TC = 100°C | 3 |+| Drain current (pulsed) | IDM |  |  | 320 | A | Pulse width limited by safe operating area | 3 |+| Total dissipation | PTOT |  |  | 300 | W | TC = 25°C | 3 |+| Derating factor |  |  |  | 2 | W/°C |  | 3 |+| Peak diode recovery voltage slope | dv/dt |  |  | 12 | V/ns | ISD ≤ 80A, di/dt ≤300A/µs, VDD ≤ V(BR)DSS, Tj ≤ TJmax | 3 |+| Single pulse avalanche energy | EAS |  |  | 700 | mJ | Starting TJ = 25°C, ID = 40A, VDD = 37.5V | 3 |+| Operating junction temperature | TJ | -55 |  | 175 | °C |  | 3 |+| Storage temperature | Tstg | -55 |  | 175 | °C |  | 3 |+| Thermal resistance junction-case | RthJC |  |  | 0.5 | °C/W |  | 3 |+| Thermal resistance junction-ambient | RthJA |  |  | 62.5 | °C/W |  | 3 |+| Maximum lead temperature for soldering purpose | Tl |  |  | 300 | °C | 1.6mm from case for 10 sec | 3 |+| Drain-source breakdown voltage | V(BR)DSS | 75 |  |  | V | ID = 250µA, VGS = 0 | 4 |+| Zero gate voltage drain current | IDSS |  |  | 1 | µA | VDS = Max rating, VGS = 0 | 4 |+| Zero gate voltage drain current | IDSS |  |  | 10 | µA | VDS = Max rating @125°C | 4 |+| Gate body leakage current | IGSS | -100 |  | 100 | nA | VDS = 0, VGS = ±20V | 4 |+| Gate threshold voltage | VGS(th) | 2 | 3 | 4 | V | VDS = VGS, ID = 250µA | 4 |+| Static drain-source on resistance | RDS(on) |  | 0.0095 | 0.011 | Ω | VGS = 10V, ID = 40A | 4 |+| Forward transconductance | gfs | 20 |  |  | S | VDS = 15V, ID = 40A; pulsed, pulse duration 300µs, duty cycle 1.5% | 4 |+| Total gate charge | Qg |  | 117 | 160 | nC | VDD = 60V, ID = 80A, VGS = 10V | 4 |+| Forward on voltage | VSD |  |  | 1.5 | V | ISD = 80A, VGS = 0; pulsed, pulse duration 300µs, duty cycle 1.5% | 5 |+| Source-drain current | ISD |  |  | 80 | A |  | 5 |+| Source-drain current (pulsed) | ISDM |  |  | 320 | A | Pulse width limited by safe operating area | 5 |+ ## CAD (KiCad official)  - Symbol: `STP75NF75`
page.json+319
@@ -135,6 +135,325 @@       "Package": "TO-220",       "Category": "Transistors/Thyristors",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "46c09e842f61b285",+      "rows": [+        {+          "name": "Drain-source voltage",+          "symbol": "VDS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 75,+          "conditions": "VGS = 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Drain-gate voltage",+          "symbol": "VDGR",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 75,+          "conditions": "RGS = 20KΩ",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Gate-source voltage",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Drain current (continuous)",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 80,+          "conditions": "TC = 25°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Drain current (continuous)",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 70,+          "conditions": "TC = 100°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Drain current (pulsed)",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 320,+          "conditions": "Pulse width limited by safe operating area",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Total dissipation",+          "symbol": "PTOT",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "TC = 25°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Derating factor",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "W/°C",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Peak diode recovery voltage slope",+          "symbol": "dv/dt",+          "kind": "absolute_maximum",+          "unit": "V/ns",+          "min": null,+          "typ": null,+          "max": 12,+          "conditions": "ISD ≤ 80A, di/dt ≤300A/µs, VDD ≤ V(BR)DSS, Tj ≤ TJmax",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Single pulse avalanche energy",+          "symbol": "EAS",+          "kind": "absolute_maximum",+          "unit": "mJ",+          "min": null,+          "typ": null,+          "max": 700,+          "conditions": "Starting TJ = 25°C, ID = 40A, VDD = 37.5V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating junction temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 175,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 175,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance junction-case",+          "symbol": "RthJC",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance junction-ambient",+          "symbol": "RthJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 62.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Maximum lead temperature for soldering purpose",+          "symbol": "Tl",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "1.6mm from case for 10 sec",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Drain-source breakdown voltage",+          "symbol": "V(BR)DSS",+          "kind": "electrical",+          "unit": "V",+          "min": 75,+          "typ": null,+          "max": null,+          "conditions": "ID = 250µA, VGS = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Zero gate voltage drain current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VDS = Max rating, VGS = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Zero gate voltage drain current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "VDS = Max rating @125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Gate body leakage current",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "nA",+          "min": -100,+          "typ": null,+          "max": 100,+          "conditions": "VDS = 0, VGS = ±20V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Gate threshold voltage",+          "symbol": "VGS(th)",+          "kind": "electrical",+          "unit": "V",+          "min": 2,+          "typ": 3,+          "max": 4,+          "conditions": "VDS = VGS, ID = 250µA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Static drain-source on resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.0095,+          "max": 0.011,+          "conditions": "VGS = 10V, ID = 40A",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Forward transconductance",+          "symbol": "gfs",+          "kind": "electrical",+          "unit": "S",+          "min": 20,+          "typ": null,+          "max": null,+          "conditions": "VDS = 15V, ID = 40A; pulsed, pulse duration 300µs, duty cycle 1.5%",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Total gate charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 117,+          "max": 160,+          "conditions": "VDD = 60V, ID = 80A, VGS = 10V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Forward on voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.5,+          "conditions": "ISD = 80A, VGS = 0; pulsed, pulse duration 300µs, duty cycle 1.5%",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Source-drain current",+          "symbol": "ISD",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 80,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Source-drain current (pulsed)",+          "symbol": "ISDM",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 320,+          "conditions": "Pulse width limited by safe operating area",+          "source_page": 5,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],