← Commit history
stp15n80k5: specified limits as data (metadata.characteristics, 20 rows from the datasheet)
2 files changed
+274
README.md+27@@ -21,6 +21,33 @@ STP15N80K5 from STMicroelectronics, in a TO-220. Pinout and pin descriptions ext | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Gate-source voltage | VGS | -30 | | 30 | V | | 2 |+| Drain current (continuous) at TC = 25 °C | ID | | | 14 | A | TC = 25 °C | 2 |+| Drain current (continuous) at TC = 100 °C | ID | | | 8.8 | A | TC = 100 °C | 2 |+| Drain current (pulsed) | IDM | | | 56 | A | Pulse width limited by safe operating area | 2 |+| Total power dissipation at TC = 25 °C | PTOT | | | 190 | W | TC = 25 °C | 2 |+| Peak diode recovery voltage slope | dv/dt | | | 4.5 | V/ns | ISD ≤ 14 A, di/dt ≤ 100 A/µs, VDS (peak) < V(BR)DSS | 2 |+| Operating junction temperature range | TJ | -55 | | 150 | °C | | 2 |+| Avalanche current, repetitive or non-repetitive (pulse width limited by TJ max.) | IAR | | | 4 | A | Pulse width limited by TJ max. | 2 |+| Single pulse avalanche energy | EAS | | | 150 | mJ | Starting TJ = 25 °C, ID = IAR, VDD = 50 V | 2 |+| Drain-source breakdown voltage | V(BR)DSS | 800 | | | V | ID = 1 mA, VGS = 0 V | 3 |+| Zero gate voltage drain current | IDSS | | | 1 | µA | VGS = 0 V, VDS = 800 V | 3 |+| Zero gate voltage drain current (TC = 125 °C) | IDSS | | | 50 | µA | VGS = 0 V, VDS = 800 V, TC = 125 °C (specified by design, not tested in production) | 3 |+| Gate body leakage current | IGSS | -10 | | 10 | μA | VGS = ±20 V, VDS = 0 V | 3 |+| Gate threshold voltage | VGS(th) | 3 | 4 | 5 | V | VDS = VGS, ID = 100 µA | 3 |+| Static drain-source on-resistance | RDS(on) | | 300 | 375 | mΩ | VGS = 10 V, ID = 7 A | 3 |+| Source-drain current | ISD | | | 14 | A | | 4 |+| Source-drain current (pulsed) | ISDM | | | 56 | A | Pulse width limited by safe operating area | 4 |+| Forward on voltage | VSD | | | 1.5 | V | ISD = 14 A, VGS = 0 V | 4 |+| Thermal resistance, junction-to-case | RthJC | | | 0.66 | °C/W | | 2 |+| Thermal resistance, junction-to-ambient (TO-220) | RthJA | | | 62.5 | °C/W | | 2 |+ ## CAD (KiCad official) - Symbol: `STP15N80K5`
page.json+247@@ -148,6 +148,253 @@ "Package": "TO-220", "Category": "Transistors/Thyristors", "Pins": "3"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "21163c0da96dc474",+ "rows": [+ {+ "name": "Gate-source voltage",+ "symbol": "VGS",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -30,+ "typ": null,+ "max": 30,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Drain current (continuous) at TC = 25 °C",+ "symbol": "ID",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 14,+ "conditions": "TC = 25 °C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Drain current (continuous) at TC = 100 °C",+ "symbol": "ID",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 8.8,+ "conditions": "TC = 100 °C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Drain current (pulsed)",+ "symbol": "IDM",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 56,+ "conditions": "Pulse width limited by safe operating area",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Total power dissipation at TC = 25 °C",+ "symbol": "PTOT",+ "kind": "absolute_maximum",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 190,+ "conditions": "TC = 25 °C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Peak diode recovery voltage slope",+ "symbol": "dv/dt",+ "kind": "absolute_maximum",+ "unit": "V/ns",+ "min": null,+ "typ": null,+ "max": 4.5,+ "conditions": "ISD ≤ 14 A, di/dt ≤ 100 A/µs, VDS (peak) < V(BR)DSS",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature range",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Avalanche current, repetitive or non-repetitive (pulse width limited by TJ max.)",+ "symbol": "IAR",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 4,+ "conditions": "Pulse width limited by TJ max.",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Single pulse avalanche energy",+ "symbol": "EAS",+ "kind": "absolute_maximum",+ "unit": "mJ",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "Starting TJ = 25 °C, ID = IAR, VDD = 50 V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Drain-source breakdown voltage",+ "symbol": "V(BR)DSS",+ "kind": "electrical",+ "unit": "V",+ "min": 800,+ "typ": null,+ "max": null,+ "conditions": "ID = 1 mA, VGS = 0 V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Zero gate voltage drain current",+ "symbol": "IDSS",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "VGS = 0 V, VDS = 800 V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Zero gate voltage drain current (TC = 125 °C)",+ "symbol": "IDSS",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "VGS = 0 V, VDS = 800 V, TC = 125 °C (specified by design, not tested in production)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Gate body leakage current",+ "symbol": "IGSS",+ "kind": "electrical",+ "unit": "μA",+ "min": -10,+ "typ": null,+ "max": 10,+ "conditions": "VGS = ±20 V, VDS = 0 V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Gate threshold voltage",+ "symbol": "VGS(th)",+ "kind": "electrical",+ "unit": "V",+ "min": 3,+ "typ": 4,+ "max": 5,+ "conditions": "VDS = VGS, ID = 100 µA",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Static drain-source on-resistance",+ "symbol": "RDS(on)",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": 300,+ "max": 375,+ "conditions": "VGS = 10 V, ID = 7 A",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Source-drain current",+ "symbol": "ISD",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 14,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Source-drain current (pulsed)",+ "symbol": "ISDM",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 56,+ "conditions": "Pulse width limited by safe operating area",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Forward on voltage",+ "symbol": "VSD",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "ISD = 14 A, VGS = 0 V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance, junction-to-case",+ "symbol": "RthJC",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": null,+ "max": 0.66,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance, junction-to-ambient (TO-220)",+ "symbol": "RthJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": null,+ "max": 62.5,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ }+ ] } }, "variants": [],