← Commit history

Set visibility: public

Ray ·5b2f8e82c5 · ·parent b308cd9
1 file changed +10−7
page.json+10−7
@@ -64,37 +64,37 @@         "number": "3",         "name": "EN1",         "type": "input",-        "description": "Active-high enable input for channel 1; apply \u22652.0 V to turn ON the power switch with maximum 5 ms turn-on time, \u22640.8 V to turn OFF."+        "description": "Active-high enable input for channel 1; apply ≥2.0 V to turn ON the power switch with maximum 5 ms turn-on time, ≤0.8 V to turn OFF."       },       {         "number": "4",         "name": "EN2",         "type": "input",-        "description": "Active-high enable input for channel 2; apply \u22652.0 V to turn ON the power switch with maximum 5 ms turn-on time, \u22640.8 V to turn OFF."+        "description": "Active-high enable input for channel 2; apply ≥2.0 V to turn ON the power switch with maximum 5 ms turn-on time, ≤0.8 V to turn OFF."       },       {         "number": "5",         "name": "OC2",         "type": "tri_state",-        "description": "Open-drain fault output for channel 2; asserts low (\u22640.4 V) when overcurrent or thermal shutdown is detected, after 4-15 ms fault blanking delay."+        "description": "Open-drain fault output for channel 2; asserts low (≤0.4 V) when overcurrent or thermal shutdown is detected, after 4-15 ms fault blanking delay."       },       {         "number": "6",         "name": "OUT2",         "type": "power_out",-        "description": "High-side power output of channel 2; delivers up to 500 mA continuous current with on-state resistance of 105-115 m\u03a9 at VI = 5.0 V."+        "description": "High-side power output of channel 2; delivers up to 500 mA continuous current with on-state resistance of 105-115 mΩ at VI = 5.0 V."       },       {         "number": "7",         "name": "OUT1",         "type": "power_out",-        "description": "High-side power output of channel 1; delivers up to 500 mA continuous current with on-state resistance of 105-115 m\u03a9 at VI = 5.0 V."+        "description": "High-side power output of channel 1; delivers up to 500 mA continuous current with on-state resistance of 105-115 mΩ at VI = 5.0 V."       },       {         "number": "8",         "name": "OC1",         "type": "tri_state",-        "description": "Open-drain fault output for channel 1; asserts low (\u22640.4 V) when overcurrent or thermal shutdown is detected, after 4-15 ms fault blanking delay."+        "description": "Open-drain fault output for channel 1; asserts low (≤0.4 V) when overcurrent or thermal shutdown is detected, after 4-15 ms fault blanking delay."       }     ],     "provenance": {@@ -172,5 +172,8 @@     "docs/stmps2252mtr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file