← Commit history

stb80nf03l-04t4: specified limits as data (metadata.characteristics, 37 rows from the datasheet)

Ray ·4cdce8f9ac · ·parent 520472b
2 files changed +496−1
README.md+44
@@ -21,6 +21,50 @@ STB80NF03L-04T4 from STMicroelectronics, in a D2PAK. Pinout and pin descriptions | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Drain-source voltage (VGS = 0) | VDS |  |  | 30 | V | VGS = 0 | 3 |+| Gate-source voltage | VGS | -20 |  | 20 | V |  | 3 |+| Drain current (continuous) | ID |  |  | 80 | A | TC = 25 °C; limited by package | 3 |+| Drain current (pulsed) | IDM |  |  | 320 | A | Pulse width limited by safe operating area | 3 |+| Total dissipation | PTOT |  |  | 300 | W | TC = 25 °C | 3 |+| Derating factor |  |  |  | 2 | W/°C |  | 3 |+| Peak diode recovery voltage slope | dv/dt |  |  | 2 | V/ns | ISD ≤ 80 A, di/dt ≤ 240 A/µs, VDD ≤ V(BR)DSS, TJ ≤ TJMAX | 3 |+| Single pulse avalanche energy | EAS |  |  | 2.3 | J | Starting Tj = 25 °C, ID = 80 A, VDD = 50 V | 3 |+| Storage temperature | Tstg | -60 |  | 175 | °C |  | 3 |+| Operating junction temperature | Tj | -60 |  | 175 | °C |  | 3 |+| Thermal resistance junction-case | Rthj-case |  |  | 0.5 | °C/W |  | 3 |+| Thermal resistance junction-ambient | Rthj-amb |  |  | 62.5 | °C/W |  | 3 |+| Maximum lead temperature for soldering purpose | Tl |  |  | 300 | °C |  | 3 |+| Drain-source breakdown voltage | V(BR)DSS | 30 |  |  | V | ID = 250 µA, VGS = 0 | 4 |+| Zero gate voltage drain current | IDSS |  |  | 1 | µA | VGS = 0, VDS = max rating | 4 |+| Zero gate voltage drain current | IDSS |  |  | 10 | µA | VGS = 0, VDS = max rating @125 °C | 4 |+| Gate-body leakage current | IGSS | -100 |  | 100 | nA | VDS = 0, VGS = ±20 V | 4 |+| Gate threshold voltage | VGS(th) | 1 |  |  | V | VDS = VGS, ID = 250 µA | 4 |+| Static drain-source on resistance | RDS(on) |  | 0.0035 | 0.004 | Ω | VGS = 10 V, ID = 40 A | 4 |+| Static drain-source on resistance | RDS(on) |  | 0.004 | 0.0055 | Ω | VGS = 4.5 V, ID = 40 A | 4 |+| Total gate charge | Qg |  | 85 | 110 | nC | VDD = 24 V, ID = 80 A, VGS = 4.5 V (Figure 15) | 4 |+| Source-drain current | ISD |  |  | 80 | A |  | 5 |+| Source-drain current (pulsed) | ISDM |  |  | 320 | A | Pulse width limited by safe operating area | 5 |+| Forward on voltage | VSD |  |  | 1.5 | V | ISD = 80 A, VGS = 0; pulse duration = 300 µs, duty cycle 1.5% | 5 |+| Forward transconductance | gfs |  | 50 |  | S | VDS = 15 V, ID = 15 A; pulsed: pulse duration = 300 µs, duty cycle 1.5% | 4 |+| Input capacitance | Ciss |  | 5500 |  | pF | VDS = 25 V, f = 1 MHz, VGS = 0 | 4 |+| Output capacitance | Coss |  | 1670 |  | pF | VDS = 25 V, f = 1 MHz, VGS = 0 | 4 |+| Reverse transfer capacitance | Crss |  | 290 |  | pF | VDS = 25 V, f = 1 MHz, VGS = 0 | 4 |+| Gate-source charge | Qgs |  | 23 |  | nC | VDD = 24 V, ID = 80 A, VGS = 4.5 V (Figure 15) | 4 |+| Gate-drain charge | Qgd |  | 40 |  | nC | VDD = 24 V, ID = 80 A, VGS = 4.5 V (Figure 15) | 4 |+| Turn-on delay time | td(on) |  | 30 |  | ns | VDD = 15 V, ID = 40 A, RG = 4.7 Ω, VGS = 4.5 V (Figure 16) | 5 |+| Rise time | tr |  | 270 |  | ns | VDD = 15 V, ID = 40 A, RG = 4.7 Ω, VGS = 4.5 V (Figure 16) | 5 |+| Turn-off delay time | td(off) |  | 110 |  | ns | VDD = 15 V, ID = 40 A, RG = 4.7 Ω, VGS = 4.5 V (Figure 16) | 5 |+| Fall time | tf |  | 95 |  | ns | VDD = 15 V, ID = 40 A, RG = 4.7 Ω, VGS = 4.5 V (Figure 16) | 5 |+| Reverse recovery time | trr |  | 75 |  | ns | ISD = 80 A, VDD = 20 V, di/dt = 100 A/µs, Tj = 150 °C | 5 |+| Reverse recovery charge | Qrr |  | 0.15 |  | µC | ISD = 80 A, VDD = 20 V, di/dt = 100 A/µs, Tj = 150 °C | 5 |+| Reverse recovery current | IRRM |  | 4 |  | A | ISD = 80 A, VDD = 20 V, di/dt = 100 A/µs, Tj = 150 °C | 5 |+ ## CAD (KiCad official)  - Symbol: `STB80NF03L-04T4`
page.json+452−1
@@ -152,6 +152,457 @@       "Package": "D2PAK",       "Category": "Transistors/Thyristors",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "08f6a2ed93fc6af8",+      "rows": [+        {+          "name": "Drain-source voltage (VGS = 0)",+          "symbol": "VDS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "VGS = 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Gate-source voltage",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Drain current (continuous)",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 80,+          "conditions": "TC = 25 °C; limited by package",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Drain current (pulsed)",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 320,+          "conditions": "Pulse width limited by safe operating area",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Total dissipation",+          "symbol": "PTOT",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "TC = 25 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Derating factor",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "W/°C",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Peak diode recovery voltage slope",+          "symbol": "dv/dt",+          "kind": "absolute_maximum",+          "unit": "V/ns",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "ISD ≤ 80 A, di/dt ≤ 240 A/µs, VDD ≤ V(BR)DSS, TJ ≤ TJMAX",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Single pulse avalanche energy",+          "symbol": "EAS",+          "kind": "absolute_maximum",+          "unit": "J",+          "min": null,+          "typ": null,+          "max": 2.3,+          "conditions": "Starting Tj = 25 °C, ID = 80 A, VDD = 50 V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -60,+          "typ": null,+          "max": 175,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating junction temperature",+          "symbol": "Tj",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -60,+          "typ": null,+          "max": 175,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance junction-case",+          "symbol": "Rthj-case",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance junction-ambient",+          "symbol": "Rthj-amb",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 62.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Maximum lead temperature for soldering purpose",+          "symbol": "Tl",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Drain-source breakdown voltage",+          "symbol": "V(BR)DSS",+          "kind": "electrical",+          "unit": "V",+          "min": 30,+          "typ": null,+          "max": null,+          "conditions": "ID = 250 µA, VGS = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Zero gate voltage drain current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VGS = 0, VDS = max rating",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Zero gate voltage drain current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "VGS = 0, VDS = max rating @125 °C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Gate-body leakage current",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "nA",+          "min": -100,+          "typ": null,+          "max": 100,+          "conditions": "VDS = 0, VGS = ±20 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Gate threshold voltage",+          "symbol": "VGS(th)",+          "kind": "electrical",+          "unit": "V",+          "min": 1,+          "typ": null,+          "max": null,+          "conditions": "VDS = VGS, ID = 250 µA",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Static drain-source on resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.0035,+          "max": 0.004,+          "conditions": "VGS = 10 V, ID = 40 A",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Static drain-source on resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.004,+          "max": 0.0055,+          "conditions": "VGS = 4.5 V, ID = 40 A",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Total gate charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 85,+          "max": 110,+          "conditions": "VDD = 24 V, ID = 80 A, VGS = 4.5 V (Figure 15)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Source-drain current",+          "symbol": "ISD",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 80,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Source-drain current (pulsed)",+          "symbol": "ISDM",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 320,+          "conditions": "Pulse width limited by safe operating area",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Forward on voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.5,+          "conditions": "ISD = 80 A, VGS = 0; pulse duration = 300 µs, duty cycle 1.5%",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Forward transconductance",+          "symbol": "gfs",+          "kind": "electrical",+          "unit": "S",+          "min": null,+          "typ": 50,+          "max": null,+          "conditions": "VDS = 15 V, ID = 15 A; pulsed: pulse duration = 300 µs, duty cycle 1.5%",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input capacitance",+          "symbol": "Ciss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 5500,+          "max": null,+          "conditions": "VDS = 25 V, f = 1 MHz, VGS = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output capacitance",+          "symbol": "Coss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 1670,+          "max": null,+          "conditions": "VDS = 25 V, f = 1 MHz, VGS = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reverse transfer capacitance",+          "symbol": "Crss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 290,+          "max": null,+          "conditions": "VDS = 25 V, f = 1 MHz, VGS = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Gate-source charge",+          "symbol": "Qgs",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 23,+          "max": null,+          "conditions": "VDD = 24 V, ID = 80 A, VGS = 4.5 V (Figure 15)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Gate-drain charge",+          "symbol": "Qgd",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 40,+          "max": null,+          "conditions": "VDD = 24 V, ID = 80 A, VGS = 4.5 V (Figure 15)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Turn-on delay time",+          "symbol": "td(on)",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 30,+          "max": null,+          "conditions": "VDD = 15 V, ID = 40 A, RG = 4.7 Ω, VGS = 4.5 V (Figure 16)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Rise time",+          "symbol": "tr",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 270,+          "max": null,+          "conditions": "VDD = 15 V, ID = 40 A, RG = 4.7 Ω, VGS = 4.5 V (Figure 16)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Turn-off delay time",+          "symbol": "td(off)",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 110,+          "max": null,+          "conditions": "VDD = 15 V, ID = 40 A, RG = 4.7 Ω, VGS = 4.5 V (Figure 16)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Fall time",+          "symbol": "tf",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 95,+          "max": null,+          "conditions": "VDD = 15 V, ID = 40 A, RG = 4.7 Ω, VGS = 4.5 V (Figure 16)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Reverse recovery time",+          "symbol": "trr",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 75,+          "max": null,+          "conditions": "ISD = 80 A, VDD = 20 V, di/dt = 100 A/µs, Tj = 150 °C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Reverse recovery charge",+          "symbol": "Qrr",+          "kind": "electrical",+          "unit": "µC",+          "min": null,+          "typ": 0.15,+          "max": null,+          "conditions": "ISD = 80 A, VDD = 20 V, di/dt = 100 A/µs, Tj = 150 °C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Reverse recovery current",+          "symbol": "IRRM",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 4,+          "max": null,+          "conditions": "ISD = 80 A, VDD = 20 V, di/dt = 100 A/µs, Tj = 150 °C",+          "source_page": 5,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -193,4 +644,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}