← Commit history
page.json+5−2@@ -32,7 +32,7 @@ "number": "1", "name": "VOUT", "type": "output",- "description": "N-channel open-drain detector output. Pulls low (to VSS) when VDD \u2264 VDET(-) = 1.8V; high-impedance (Hi-Z) when VDD > VDET(+). Requires external pull-up resistor (e.g. 100k\u03a9) to VDD or a separate rail. IOL \u2265 0.5mA (typ. 1mA) at VOUT=0.2V with Vin=2V."+ "description": "N-channel open-drain detector output. Pulls low (to VSS) when VDD ≤ VDET(-) = 1.8V; high-impedance (Hi-Z) when VDD > VDET(+). Requires external pull-up resistor (e.g. 100kΩ) to VDD or a separate rail. IOL ≥ 0.5mA (typ. 1mA) at VOUT=0.2V with Vin=2V." }, { "number": "2",@@ -118,5 +118,8 @@ "docs/ssp61cn1802mr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }