← Commit history

Set visibility: public

Ray ·0f3530b277 · ·parent fa7d293
1 file changed +22−19
page.json+22−19
@@ -32,55 +32,55 @@         "number": "1",         "name": "DIR",         "type": "input",-        "description": "Direction control input. When HIGH, data flows from A-port to B-port; when LOW, data flows from B-port to A-port. TTL-compatible input (VIH \u2265 2V, VIL \u2264 0.8V)."+        "description": "Direction control input. When HIGH, data flows from A-port to B-port; when LOW, data flows from B-port to A-port. TTL-compatible input (VIH ≥ 2V, VIL ≤ 0.8V)."       },       {         "number": "2",         "name": "A1",         "type": "bidirectional",-        "description": "Channel 1 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 1 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "3",         "name": "A2",         "type": "bidirectional",-        "description": "Channel 2 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 2 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "4",         "name": "A3",         "type": "bidirectional",-        "description": "Channel 3 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 3 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "5",         "name": "A4",         "type": "bidirectional",-        "description": "Channel 4 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 4 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "6",         "name": "A5",         "type": "bidirectional",-        "description": "Channel 5 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 5 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "7",         "name": "A6",         "type": "bidirectional",-        "description": "Channel 6 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 6 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "8",         "name": "A7",         "type": "bidirectional",-        "description": "Channel 7 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 7 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "9",         "name": "A8",         "type": "bidirectional",-        "description": "Channel 8 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 8 A-side data I/O. Acts as input when DIR=LOW, output when DIR=HIGH (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "10",@@ -92,49 +92,49 @@         "number": "11",         "name": "B8",         "type": "bidirectional",-        "description": "Channel 8 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 8 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "12",         "name": "B7",         "type": "bidirectional",-        "description": "Channel 7 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 7 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "13",         "name": "B6",         "type": "bidirectional",-        "description": "Channel 6 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 6 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "14",         "name": "B5",         "type": "bidirectional",-        "description": "Channel 5 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 5 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "15",         "name": "B4",         "type": "bidirectional",-        "description": "Channel 4 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 4 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "16",         "name": "B3",         "type": "bidirectional",-        "description": "Channel 3 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 3 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "17",         "name": "B2",         "type": "bidirectional",-        "description": "Channel 2 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 2 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "18",         "name": "B1",         "type": "bidirectional",-        "description": "Channel 1 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = \u00b124 mA."+        "description": "Channel 1 B-side data I/O. Acts as input when DIR=HIGH, output when DIR=LOW (and OE=LOW). IOH/IOL = ±24 mA."       },       {         "number": "19",@@ -146,7 +146,7 @@         "number": "20",         "name": "VCC",         "type": "power_in",-        "description": "Positive supply voltage input. Operating range 4.5 V to 5.5 V. Bypass locally to GND with a 0.1 \u00b5F ceramic capacitor."+        "description": "Positive supply voltage input. Operating range 4.5 V to 5.5 V. Bypass locally to GND with a 0.1 µF ceramic capacitor."       }     ],     "provenance": {@@ -210,5 +210,8 @@     "docs/sn74act245pwr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file