← Commit history
page.json+7−4@@ -62,19 +62,19 @@ "number": "6", "name": "CANL", "type": "bidirectional",- "description": "Low-level CAN differential bus line. Fault-protected to \u00b136 V and transient-protected to \u00b1100 V through 100 \u03a9 (per ISO 7637)."+ "description": "Low-level CAN differential bus line. Fault-protected to ±36 V and transient-protected to ±100 V through 100 Ω (per ISO 7637)." }, { "number": "7", "name": "CANH", "type": "bidirectional",- "description": "High-level CAN differential bus line. Fault-protected to \u00b136 V and transient-protected to \u00b1100 V through 100 \u03a9."+ "description": "High-level CAN differential bus line. Fault-protected to ±36 V and transient-protected to ±100 V through 100 Ω." }, { "number": "8", "name": "RS", "type": "input",- "description": "Mode select pin. Strong pulldown to GND selects high-speed mode; strong pullup to VCC selects low-power (standby/listen-only) mode; a 10 k\u03a9 to 100 k\u03a9 pulldown resistor selects slope-control mode (\u224815 V/\u00b5s at 10 k\u03a9, \u22482 V/\u00b5s at 100 k\u03a9)."+ "description": "Mode select pin. Strong pulldown to GND selects high-speed mode; strong pullup to VCC selects low-power (standby/listen-only) mode; a 10 kΩ to 100 kΩ pulldown resistor selects slope-control mode (≈15 V/µs at 10 kΩ, ≈2 V/µs at 100 kΩ)." } ], "provenance": {@@ -138,5 +138,8 @@ "docs/sn65hvd235dr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }