← Commit history

Set visibility: public

Ray ·98dfc5b472 · ·parent ea48f2c
1 file changed +17−14
page.json+17−14
@@ -38,7 +38,7 @@         "number": "1",         "name": "C1+",         "type": "passive",-        "description": "Positive terminal of charge-pump flying capacitor C1; external capacitor value is 0.1 \u00b5F at VCC = 3.3 V or 0.047 \u00b5F at VCC = 5 V."+        "description": "Positive terminal of charge-pump flying capacitor C1; external capacitor value is 0.1 µF at VCC = 3.3 V or 0.047 µF at VCC = 5 V."       },       {         "number": "2",@@ -56,7 +56,7 @@         "number": "4",         "name": "C2+",         "type": "passive",-        "description": "Positive terminal of charge-pump flying capacitor C2; external capacitor value is 0.1 \u00b5F at VCC = 3.3 V or 0.33 \u00b5F at VCC = 5 V."+        "description": "Positive terminal of charge-pump flying capacitor C2; external capacitor value is 0.1 µF at VCC = 3.3 V or 0.33 µF at VCC = 5 V."       },       {         "number": "5",@@ -68,67 +68,67 @@         "number": "6",         "name": "V-",         "type": "power_out",-        "description": "Negative charge-pump output for external storage capacitor only; absolute maximum \u22127 V with respect to GND."+        "description": "Negative charge-pump output for external storage capacitor only; absolute maximum −7 V with respect to GND."       },       {         "number": "7",         "name": "DOUT2",         "type": "output",-        "description": "RS-232 channel 2 line driver output to remote RS-232 system; \u00b115-kV HBM and \u00b115-kV IEC 61000-4-2 air-gap ESD protected; VOH \u2265 +5 V, VOL \u2264 \u22125 V into 3 k\u03a9."+        "description": "RS-232 channel 2 line driver output to remote RS-232 system; ±15-kV HBM and ±15-kV IEC 61000-4-2 air-gap ESD protected; VOH ≥ +5 V, VOL ≤ −5 V into 3 kΩ."       },       {         "number": "8",         "name": "RIN2",         "type": "input",-        "description": "RS-232 channel 2 line receiver input from remote RS-232 system; \u00b115-kV HBM and \u00b115-kV IEC 61000-4-2 ESD protected; input range \u00b125 V, internal 3-7 k\u03a9 load."+        "description": "RS-232 channel 2 line receiver input from remote RS-232 system; ±15-kV HBM and ±15-kV IEC 61000-4-2 ESD protected; input range ±25 V, internal 3-7 kΩ load."       },       {         "number": "9",         "name": "ROUT2",         "type": "output",-        "description": "Logic-level receiver channel 2 output to UART; output is high when RIN2 is open or driver is off; VOH \u2265 VCC \u2212 0.6 V at IOH = \u22121 mA."+        "description": "Logic-level receiver channel 2 output to UART; output is high when RIN2 is open or driver is off; VOH ≥ VCC − 0.6 V at IOH = −1 mA."       },       {         "number": "10",         "name": "DIN2",         "type": "input",-        "description": "Logic-level driver channel 2 input from UART; VIH \u2265 2 V (VCC = 3.3 V) or \u2265 2.4 V (VCC = 5 V); VIL \u2264 0.8 V; input range 0 to 5.5 V."+        "description": "Logic-level driver channel 2 input from UART; VIH ≥ 2 V (VCC = 3.3 V) or ≥ 2.4 V (VCC = 5 V); VIL ≤ 0.8 V; input range 0 to 5.5 V."       },       {         "number": "11",         "name": "DIN1",         "type": "input",-        "description": "Logic-level driver channel 1 input from UART; VIH \u2265 2 V (VCC = 3.3 V) or \u2265 2.4 V (VCC = 5 V); VIL \u2264 0.8 V; input range 0 to 5.5 V."+        "description": "Logic-level driver channel 1 input from UART; VIH ≥ 2 V (VCC = 3.3 V) or ≥ 2.4 V (VCC = 5 V); VIL ≤ 0.8 V; input range 0 to 5.5 V."       },       {         "number": "12",         "name": "ROUT1",         "type": "output",-        "description": "Logic-level receiver channel 1 output to UART; output is high when RIN1 is open or driver is off; VOH \u2265 VCC \u2212 0.6 V at IOH = \u22121 mA."+        "description": "Logic-level receiver channel 1 output to UART; output is high when RIN1 is open or driver is off; VOH ≥ VCC − 0.6 V at IOH = −1 mA."       },       {         "number": "13",         "name": "RIN1",         "type": "input",-        "description": "RS-232 channel 1 line receiver input from remote RS-232 system; \u00b115-kV HBM and \u00b115-kV IEC 61000-4-2 ESD protected; input range \u00b125 V, internal 3-7 k\u03a9 load."+        "description": "RS-232 channel 1 line receiver input from remote RS-232 system; ±15-kV HBM and ±15-kV IEC 61000-4-2 ESD protected; input range ±25 V, internal 3-7 kΩ load."       },       {         "number": "14",         "name": "DOUT1",         "type": "output",-        "description": "RS-232 channel 1 line driver output to remote RS-232 system; \u00b115-kV HBM and \u00b115-kV IEC 61000-4-2 air-gap ESD protected; VOH \u2265 +5 V, VOL \u2264 \u22125 V into 3 k\u03a9."+        "description": "RS-232 channel 1 line driver output to remote RS-232 system; ±15-kV HBM and ±15-kV IEC 61000-4-2 air-gap ESD protected; VOH ≥ +5 V, VOL ≤ −5 V into 3 kΩ."       },       {         "number": "15",         "name": "GND",         "type": "power_in",-        "description": "Ground reference for all voltages; included in pin-to-pin \u00b115-kV IEC ESD protection domain; 1 \u00b5F bypass capacitor between VCC and GND required for IEC ESD compliance."+        "description": "Ground reference for all voltages; included in pin-to-pin ±15-kV IEC ESD protection domain; 1 µF bypass capacitor between VCC and GND required for IEC ESD compliance."       },       {         "number": "16",         "name": "VCC",         "type": "power_in",-        "description": "Supply voltage; recommended operating range 3 V to 5.5 V; typical ICC = 300 \u00b5A, maximum ICC = 1 mA with no load."+        "description": "Supply voltage; recommended operating range 3 V to 5.5 V; typical ICC = 300 µA, maximum ICC = 1 mA with no load."       }     ],     "provenance": {@@ -206,5 +206,8 @@     "docs/sn65c3232epwr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file