component
SMF170A-TP
Public Made by Adomby adom
MCC(Micro Commercial Components) Electrostatic And Surge Protection (TVS/ESD), SOD-123FL. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.
← Commit history
page.json+212−28@@ -1,8 +1,11 @@ {+ "schema_version": 1,+ "type": "component", "slug": "smf170a-tp",+ "title": "SMF170A-TP",+ "brief": "MCC(Micro Commercial Components) Electrostatic And Surge Protection (TVS/ESD), SOD-123FL. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "version": "0.1.0",- "type": "component",- "description": "MCC(Micro Commercial Components) Electrostatic And Surge Protection (TVS/ESD), SOD-123FL. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "license": "CC-BY-SA-4.0", "tags": [ "component", "tvs-fuse-board level protection",@@ -10,26 +13,6 @@ "factory-2.0.0", "extractor-text" ],- "dependencies": {},- "hero": {- "type": "image",- "path": "docs/hero.png"- },- "files": [- "page.json",- "README.md",- "smf170a-tp.kicad_sym",- "smf170a-tp.kicad_mod",- "smf170a-tp.glb",- "smf170a-tp.step",- "smf170a-tp.lbr",- "docs/hero.png",- "docs/smf170a-tp-datasheet.pdf",- "viewers/symbol.html",- "viewers/footprint.html",- "smf170a-tp-hero.glb",- "smf170a-tp-hero.overlay.json"- ], "component": { "mpn": "SMF170A-TP", "manufacturer": "MCC(Micro Commercial Components)",@@ -126,8 +109,8 @@ 1.6, 1.1 ],- "zmin_mm": 0,- "centre_offset_mm": 0,+ "zmin_mm": -0.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "132323445e3d1f9231e81c083cd88a33cd204dd8b96063bb2ed1f3ab4470c7e7", "checked": "2026-10-30",@@ -176,10 +159,211 @@ } } },- "visibility": "public",- "org": "adom",+ "metadata": {+ "specs": {+ "Manufacturer": "MCC(Micro Commercial Components)",+ "Package": "SOD-123FL",+ "Category": "TVS/Fuse/Board Level Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "c4100e793386d984ed8105ce6a9e00ecd392577526cd7b858b96c6312299b52b",+ "rows": [+ {+ "name": "Breakdown Voltage",+ "symbol": "VBR",+ "kind": "electrical",+ "unit": "V",+ "min": 189,+ "typ": null,+ "max": 209,+ "conditions": "IT = 1.0 mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Max. Clamping Voltage",+ "symbol": "VC",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 275,+ "conditions": "at IPP 0.6 A",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Max. Peak Pulse Current",+ "symbol": "IPP",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.6,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Max. Reverse Leakage Current",+ "symbol": "ID",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "@VWM 170 V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Peak Pulse Power Dissipation",+ "symbol": "PPP",+ "kind": "absolute_maximum",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 200,+ "conditions": "10/1000µs waveform",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Peak forward surge current",+ "symbol": "IFSM",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "8.3 ms single half sine-wave",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "ESD Voltage (HBM)",+ "symbol": "VESD",+ "kind": "absolute_maximum",+ "unit": "KV",+ "min": 16,+ "typ": null,+ "max": null,+ "conditions": "HBM; printed as >16KV",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "ESD IEC61000-4-2 air discharge",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "KV",+ "min": -30,+ "typ": null,+ "max": 30,+ "conditions": "IEC61000-4-2 (ESD), air; printed ±30KV",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "ESD IEC61000-4-2 contact discharge",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "KV",+ "min": -30,+ "typ": null,+ "max": 30,+ "conditions": "IEC61000-4-2 (ESD), contact; printed ±30KV",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Operating Junction Temperature Range",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 175,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature Range",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 175,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Typical Thermal Resistance Junction to Lead",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 26,+ "max": null,+ "conditions": "typical, junction to lead",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Typical Thermal Resistance Junction to Ambient",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 300,+ "max": null,+ "conditions": "typical, junction to ambient",+ "source_page": 1,+ "source": "datasheet"+ }+ ]+ }+ },+ "variants": [],+ "sections": [+ "hero",+ "viewers",+ "readme",+ "breadcrumbs",+ "info"+ ],+ "discovery_triggers": [+ "smf170a-tp"+ ],+ "discovery_pitch": "SMF170A-TP (MCC(Micro Commercial Components)) component page: datasheet pinout, KiCad symbol, footprint and 3D.", "author": { "name": "Ray", "email": "[email protected]"- }-}+ },+ "dependencies": {},+ "hero": {+ "type": "image",+ "path": "docs/hero.png"+ },+ "files": [+ "page.json",+ "README.md",+ "smf170a-tp.kicad_sym",+ "smf170a-tp.kicad_mod",+ "smf170a-tp.glb",+ "smf170a-tp.step",+ "smf170a-tp.lbr",+ "docs/hero.png",+ "docs/smf170a-tp-datasheet.pdf",+ "viewers/symbol.html",+ "viewers/footprint.html",+ "smf170a-tp-hero.glb",+ "smf170a-tp-hero.overlay.json"+ ]+}