← Commit history
page.json+311−30@@ -1,8 +1,11 @@ {+ "schema_version": 1,+ "type": "component", "slug": "smd1812p200tf-16",+ "title": "SMD1812P200TF/16",+ "brief": "PTTC(Polytronics Tech) Resettable Fuses, 1812. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "version": "0.1.0",- "type": "component",- "description": "PTTC(Polytronics Tech) Resettable Fuses, 1812. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "license": "CC-BY-SA-4.0", "tags": [ "component", "circuit protection",@@ -10,26 +13,6 @@ "factory-2.0.0", "extractor-text" ],- "dependencies": {},- "hero": {- "type": "image",- "path": "docs/hero.png"- },- "files": [- "page.json",- "README.md",- "smd1812p200tf-16.kicad_sym",- "smd1812p200tf-16.kicad_mod",- "smd1812p200tf-16.glb",- "smd1812p200tf-16.step",- "smd1812p200tf-16.lbr",- "docs/hero.png",- "docs/smd1812p200tf-16-datasheet.pdf",- "viewers/symbol.html",- "viewers/footprint.html",- "smd1812p200tf-16-hero.glb",- "smd1812p200tf-16-hero.overlay.json"- ], "component": { "mpn": "SMD1812P200TF/16", "manufacturer": "PTTC(Polytronics Tech)",@@ -104,7 +87,7 @@ "family": "_1806_", "height_mm": 0.9, "height_basis": "family nominal (no datasheet A read)",- "standoff_mm": 0+ "standoff_mm": 0.0 }, "pins": { "total": 2,@@ -130,8 +113,8 @@ 3.22, 0.9 ],- "zmin_mm": 0,- "centre_offset_mm": 0,+ "zmin_mm": 0.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "9859e495a8a63489831d8faab738caa8ce6b48df6011c754aae168db1d641b5a", "checked": "2026-11-16",@@ -173,9 +156,307 @@ } } },- "visibility": "private",- "org": "adom",+ "metadata": {+ "specs": {+ "Manufacturer": "PTTC(Polytronics Tech)",+ "Package": "1812",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "fd00a32cd6588696ccfbaa7834793c5a9f5f2a933d01019303bf2dbe730d488e",+ "rows": [+ {+ "name": "Minimum resistance prior to trip",+ "symbol": "Rimin",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.02,+ "typ": null,+ "max": null,+ "conditions": "Minimum device resistance prior to tripping at 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance prior to trip",+ "symbol": "Ri max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "R1max: maximum device resistance measured one hour post reflow",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 2,+ "max": null,+ "conditions": "Maximum current device will not trip in 25°C still air",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Trip current",+ "symbol": "Itrip",+ "kind": "electrical",+ "unit": "A",+ "min": 4,+ "typ": null,+ "max": null,+ "conditions": "Minimum current at which the device will always trip in 25°C still air",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum operating voltage",+ "symbol": "Vmax",+ "kind": "absolute_maximum",+ "unit": "VDC",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "Maximum operating voltage device can withstand without damage at rated current (Imax)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "Imax",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 35,+ "conditions": "Maximum fault current device can withstand without damage at rated voltage (Vmax)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Power dissipation in tripped state",+ "symbol": "Pd typ",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.8,+ "max": null,+ "conditions": "Power dissipation when tripped in 25°C still air at rated voltage",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum current (Max. Current column)",+ "symbol": "",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "Max. Current column, as printed",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Time to trip",+ "symbol": "Tmax",+ "kind": "timing",+ "unit": "S",+ "min": null,+ "typ": null,+ "max": 2,+ "conditions": "Time to Trip column, as printed",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Maximum surface temperature of the device in the tripped state",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at -40 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 2.88,+ "max": null,+ "conditions": "Ambient -40 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at -20 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 2.61,+ "max": null,+ "conditions": "Ambient -20 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 0 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 2.25,+ "max": null,+ "conditions": "Ambient 0 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 25 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 2,+ "max": null,+ "conditions": "Ambient 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 40 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 1.8,+ "max": null,+ "conditions": "Ambient 40 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 50 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 1.66,+ "max": null,+ "conditions": "Ambient 50 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 60 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 1.45,+ "max": null,+ "conditions": "Ambient 60 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 70 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 1.09,+ "max": null,+ "conditions": "Ambient 70 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current derated at 85 °C",+ "symbol": "Ih",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 0.8,+ "max": null,+ "conditions": "Ambient 85 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Reflow peak temperature",+ "symbol": "TP",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": 260,+ "max": null,+ "conditions": "260 +0/-5°C; do not exceed 260°C",+ "source_page": 7,+ "source": "datasheet"+ }+ ]+ }+ },+ "variants": [],+ "sections": [+ "hero",+ "viewers",+ "readme",+ "breadcrumbs",+ "info"+ ],+ "discovery_triggers": [+ "smd1812p200tf"+ ],+ "discovery_pitch": "SMD1812P200TF (PTTC(Polytronics Tech)) component page: datasheet pinout, KiCad symbol, footprint and 3D.", "author": {- "name": "Ray"- }-}+ "name": "Ray",+ "email": "[email protected]"+ },+ "dependencies": {},+ "hero": {+ "type": "image",+ "path": "docs/hero.png"+ },+ "files": [+ "page.json",+ "README.md",+ "smd1812p200tf-16.kicad_sym",+ "smd1812p200tf-16.kicad_mod",+ "smd1812p200tf-16.glb",+ "smd1812p200tf-16.step",+ "smd1812p200tf-16.lbr",+ "docs/hero.png",+ "docs/smd1812p200tf-16-datasheet.pdf",+ "viewers/symbol.html",+ "viewers/footprint.html",+ "smd1812p200tf-16-hero.glb",+ "smd1812p200tf-16-hero.overlay.json"+ ]+}