@@ -1,6 +1,6 @@ {   "slug": "smd0603-004-15n",-  "version": "0.1.1",+  "version": "0.1.2",   "type": "component",   "description": "BORN Resettable Fuses, 0603. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "tags": [@@ -29,8 +29,6 @@     "viewers/footprint.html",     "smd0603-004-hero.glb",     "smd0603-004-hero.overlay.json",-    "smd0603-004-etched.glb",-    "smd0603-004-etched.step",     "smd0603-004-15n-hero.glb",     "smd0603-004-15n-hero.overlay.json"   ],@@ -165,5 +163,433 @@       "note": "renamed from the cut-base slug to the part it was built from (slug collision split, 2026-11-11)"     }   },-  "visibility": "public"+  "visibility": "public",+  "title": "SMD0603-004/15N",+  "brief": "BORN Resettable Fuses, 0603. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "BORN",+      "Package": "0603",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "appearance": {+      "contacts": {+        "quote": "Terminal pad materials:Tin-plated Nickel-Copper",+        "page": 4,+        "doc": "ds.pdf",+        "material": "Copper",+        "plating": "tin"+      },+      "version": 1,+      "datasheet_sha256": "aba1db431db69e761ec215bd047aef6813010ecc0c3e16329baca512ba99ef90"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "aba1db431db69e761ec215bd047aef6813010ecc0c3e16329baca512ba99ef90",+      "rows": [+        {+          "name": "Device resistance prior to tripping (Ri min)",+          "symbol": "Ri min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 4,+          "typ": null,+          "max": null,+          "conditions": "25°C, prior to tripping",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum device resistance one hour post reflow",+          "symbol": "R1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "25°C, measured one hour post reflow",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum operating voltage",+          "symbol": "V max",+          "kind": "recommended_operating",+          "unit": "V dc",+          "min": null,+          "typ": null,+          "max": 15,+          "conditions": "at rated current Imax",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "Imax",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "at rated voltage V max",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current (minimum current that always trips)",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 0.12,+          "typ": null,+          "max": null,+          "conditions": "25°C still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "ambient operating",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "device in tripped state",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, passive aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 1000 hrs; typical",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, humidity aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 85% R.H., 168 hours; typical",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, thermal shock",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85°C to -40°C, 20 times; typical",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Average ramp-up rate (Ts max to Tp)",+          "symbol": "",+          "kind": "timing",+          "unit": "℃/second",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "Pb-free assembly",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Ramp-down rate",+          "symbol": "",+          "kind": "timing",+          "unit": "℃/second",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "Pb-free assembly",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Time 25℃ to peak temperature",+          "symbol": "",+          "kind": "timing",+          "unit": "minutes",+          "min": null,+          "typ": null,+          "max": 8,+          "conditions": "25℃ to peak temperature",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Preheat temperature (Ts min to Ts max)",+          "symbol": "Ts",+          "kind": "thermal",+          "unit": "℃",+          "min": 150,+          "typ": null,+          "max": 200,+          "conditions": "Preheat, Pb-free assembly",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Preheat time (Ts min to Ts max)",+          "symbol": "",+          "kind": "timing",+          "unit": "seconds",+          "min": 60,+          "typ": null,+          "max": 180,+          "conditions": "Preheat, Pb-free assembly",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Time maintained above TL",+          "symbol": "tL",+          "kind": "timing",+          "unit": "seconds",+          "min": 60,+          "typ": null,+          "max": 150,+          "conditions": "above TL 217℃",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "℃",+          "min": 0,+          "typ": null,+          "max": 35,+          "conditions": "storage condition",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage humidity",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "%RH",+          "min": 30,+          "typ": null,+          "max": 60,+          "conditions": "storage condition",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Recommended maximum paste thickness",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "mm",+          "min": null,+          "typ": null,+          "max": 0.25,+          "conditions": "reflow",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Hold current (device will not trip, 25°C still air)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.04,+          "max": null,+          "conditions": "@25°C still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Power dissipation in tripped state",+          "symbol": "Pd",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "tripped state, 25°C still air, at rated voltage",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Time to trip",+          "symbol": "",+          "kind": "electrical",+          "unit": "Sec",+          "min": null,+          "typ": 1,+          "max": null,+          "conditions": "at trip current 0.20 A",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Peak temperature (Tp)",+          "symbol": "Tp",+          "kind": "thermal",+          "unit": "℃",+          "min": null,+          "typ": 260,+          "max": null,+          "conditions": "Pb-free reflow profile",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Time maintained above TL, liquidus temperature",+          "symbol": "TL",+          "kind": "thermal",+          "unit": "℃",+          "min": null,+          "typ": 217,+          "max": null,+          "conditions": "Pb-free reflow profile",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient -40°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.052,+          "max": null,+          "conditions": "ambient -40°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient -20°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.048,+          "max": null,+          "conditions": "ambient -20°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient 0°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.044,+          "max": null,+          "conditions": "ambient 0°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient 25°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.04,+          "max": null,+          "conditions": "ambient 25°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient 40°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.032,+          "max": null,+          "conditions": "ambient 40°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient 50°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.028,+          "max": null,+          "conditions": "ambient 50°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient 60°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.024,+          "max": null,+          "conditions": "ambient 60°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient 70°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.02,+          "max": null,+          "conditions": "ambient 70°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient 85°C",+          "symbol": "I hold",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.012,+          "max": null,+          "conditions": "ambient 85°C",+          "source_page": 2,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "smd0603-004"+  ],+  "discovery_pitch": "SMD0603-004 (BORN) component page: datasheet pinout, KiCad symbol, footprint and 3D." }
page.json+2−4
@@ -4,7 +4,7 @@   "slug": "smd0603-004-15n",   "title": "SMD0603-004/15N",   "brief": "BORN Resettable Fuses, 0603. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",-  "version": "0.1.1",+  "version": "0.1.2",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -600,12 +600,10 @@     "viewers/footprint.html",     "smd0603-004-hero.glb",     "smd0603-004-hero.overlay.json",-    "smd0603-004-etched.glb",-    "smd0603-004-etched.step",     "smd0603-004-15n-hero.glb",     "smd0603-004-15n-hero.overlay.json"   ],   "visibility": "public",   "description": "BORN Resettable Fuses, 0603. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "org": "adom"-}+}\ No newline at end of file
smd0603-004-15n-hero.glb
⋯ 1 unchanged line ⋯
smd0603-004-15n-hero.overlay.json+3−3
@@ -66,14 +66,14 @@     "seating_z_mm": -0.0   },   "sources": {-    "glb": "smd0603-004-etched.glb",-    "glb_sha256": "7c5bde531780b0a4fdbad71c2dc25de5b8d9366b77638052ffe703b76b1b6a9f",+    "glb": "smd0603-004.glb",+    "glb_sha256": "e976ba76dd3bda4551ec2980f61bb4986edc6f4e02d8ae7b4a0ad45c98466669",     "footprint": "smd0603-004.kicad_mod",     "footprint_sha256": "d2316d54a4f9c199df6983aac5aeb7a703a13ef4a6e2e9313d79cfd35d1c1e92",     "pins": "page.json component.pins",     "pins_sha256": "f89b6cef1dd40bf094bc57ef23dc246a408922a81bfac75b8bc341584ea4e214"   },-  "generator": "adom-wiki 1.8.22 (component_hero)",+  "generator": "adom-wiki 1.8.28 (component_hero)",   "labels": [     {       "pad": "1",