← Commit history

Publish 0.1.3

Ray ·8470468eeb · ·parent 7b2ea9b
2 files changed +135−6
package.json+132−3
@@ -1,6 +1,6 @@ {   "slug": "smaj54a-at-tr7",-  "version": "0.1.2",+  "version": "0.1.3",   "type": "component",   "description": "Brightking ESD And Surge Protection (TVS/ESD), SMA(DO-214AC). Diode: pin 1 is the cathode (the banded end) by the KiCad diode-footprint convention, KiCad symbol/footprint/3D.",   "tags": [@@ -46,7 +46,7 @@       "symbol": "smaj54a-at.kicad_sym",       "footprint": "smaj54a-at.kicad_mod",       "model_3d": "smaj54a-at-tr7-hero.glb",-      "model_3d_plain": "smaj54a-at-etched.glb",+      "model_3d_plain": "smaj54a-at.glb",       "model_3d_step": "smaj54a-at-etched.step",       "model_3d_step_plain": "smaj54a-at.step",       "lbr": "smaj54a-at.lbr"@@ -194,5 +194,134 @@       "source": "datasheet: p.3 table, header 'Part Number: Unidirectional | Bidirectional': row 'SMAJ54A-AT  SMAJ54CA-AT  RE ZE  54.0' (SMAJ54A-AT in Unidirectional column); pad 1 = cathode on the KiCad diode footprint (read by part-reviewer)"     }   },-  "visibility": "public"+  "visibility": "public",+  "title": "SMAJ54A-AT/TR7",+  "brief": "Brightking ESD And Surge Protection (TVS/ESD), SMA(DO-214AC). Diode: pin 1 is the cathode (the banded end) by the KiCad diode-footprint convention, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "Brightking",+      "Package": "SMA(DO-214AC)",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "b89bf590a7f5b51113e7d4578de575469733736efa701738bceaf84199b63474",+      "rows": [+        {+          "name": "Peak pulse power dissipation",+          "symbol": "PPPM",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": 400,+          "typ": null,+          "max": null,+          "conditions": "10/1000µs waveform (Note1, Note2, Fig.1)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Steady state power dissipation",+          "symbol": "PM(AV)",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 3.3,+          "conditions": "TA=50℃ (Fig.5)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Peak forward surge current",+          "symbol": "IFSM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "8.3ms single half sine-wave, JEDEC Method (Note3, Fig.6)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Operating junction and storage temperature range",+          "symbol": "TJ,TSTG",+          "kind": "absolute_maximum",+          "unit": "℃",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Typical thermal resistance junction to lead",+          "symbol": "RθJL",+          "kind": "thermal",+          "unit": "℃/W",+          "min": null,+          "typ": 30,+          "max": null,+          "conditions": "Typical",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Typical thermal resistance junction to ambient",+          "symbol": "RθJA",+          "kind": "thermal",+          "unit": "℃/W",+          "min": null,+          "typ": 120,+          "max": null,+          "conditions": "Typical",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Breakdown voltage (unidirectional SMAJ54A-AT)",+          "symbol": "VBR",+          "kind": "electrical",+          "unit": "V",+          "min": 60,+          "typ": null,+          "max": 66.3,+          "conditions": "@IT = 1 mA",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Maximum clamping voltage (unidirectional SMAJ54A-AT)",+          "symbol": "VC",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 87.1,+          "conditions": "@IPP = 4.6 A",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Reverse leakage (unidirectional SMAJ54A-AT)",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "@VRWM = 54.0 V",+          "source_page": 3,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "smaj54a-at"+  ],+  "discovery_pitch": "SMAJ54A-AT (Brightking) component page: datasheet pinout, KiCad symbol, footprint and 3D." }
page.json+3−3
@@ -4,7 +4,7 @@   "slug": "smaj54a-at-tr7",   "title": "SMAJ54A-AT/TR7",   "brief": "Brightking ESD And Surge Protection (TVS/ESD), SMA(DO-214AC). Diode: pin 1 is the cathode (the banded end) by the KiCad diode-footprint convention, KiCad symbol/footprint/3D.",-  "version": "0.1.2",+  "version": "0.1.3",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -25,7 +25,7 @@       "symbol": "smaj54a-at.kicad_sym",       "footprint": "smaj54a-at.kicad_mod",       "model_3d": "smaj54a-at-tr7-hero.glb",-      "model_3d_plain": "smaj54a-at-etched.glb",+      "model_3d_plain": "smaj54a-at.glb",       "model_3d_step": "smaj54a-at-etched.step",       "model_3d_step_plain": "smaj54a-at.step",       "lbr": "smaj54a-at.lbr"@@ -339,4 +339,4 @@   "updated_at": "2026-11-10T00:59:57.930Z",   "description": "Brightking ESD And Surge Protection (TVS/ESD), SMA(DO-214AC). Diode: pin 1 is the cathode (the banded end) by the KiCad diode-footprint convention, KiCad symbol/footprint/3D.",   "org": "adom"-}+}\ No newline at end of file