← Commit history
page.json+7−4@@ -38,7 +38,7 @@ "number": "2", "name": "REXT1", "type": "passive",- "description": "OUT-channel current-set resistor pin. IOUT = VREXT1 / Rext1, with VREXT1 \u2248 1.20 V (1.15-1.25 V). Absolute max 8 V."+ "description": "OUT-channel current-set resistor pin. IOUT = VREXT1 / Rext1, with VREXT1 ≈ 1.20 V (1.15-1.25 V). Absolute max 8 V." }, { "number": "3",@@ -50,13 +50,13 @@ "number": "4", "name": "REXT2", "type": "passive",- "description": "TRIAC-channel current-set resistor pin. ITRIAC = VREXT2 / (Rext1 + Rext2), with VREXT2 \u2248 0.30 V (0.29-0.32 V). Absolute max 8 V."+ "description": "TRIAC-channel current-set resistor pin. ITRIAC = VREXT2 / (Rext1 + Rext2), with VREXT2 ≈ 0.30 V (0.29-0.32 V). Absolute max 8 V." }, { "number": "5", "name": "TRIAC", "type": "power_in",- "description": "Combined supply input, constant-current sink output, and TRIAC-detection sense pin. Sinks the bleeder/holding current (up to 50 mA typ, saturating between ~6 V and 13 V depending on setting) and is monitored to determine whether a TRIAC dimmer is present. Absolute max 500 V; OUT_BV / TRIAC withstand \u2265 500 V."+ "description": "Combined supply input, constant-current sink output, and TRIAC-detection sense pin. Sinks the bleeder/holding current (up to 50 mA typ, saturating between ~6 V and 13 V depending on setting) and is monitored to determine whether a TRIAC dimmer is present. Absolute max 500 V; OUT_BV / TRIAC withstand ≥ 500 V." }, { "number": "6",@@ -138,5 +138,8 @@ "docs/sm2396ek-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }