← Commit history

Set visibility: public

Ray ·e239f274c6 · ·parent 3422ff3
1 file changed +11−8
page.json+11−8
@@ -32,7 +32,7 @@         "number": "1",         "name": "TXD",         "type": "input",-        "description": "Transmit data input from the CAN controller. CMOS-level logic input (VIH \u2265 2 V, VIL \u2264 0.8 V) with internal pull-up (IIL = -10 to -50 \u00b5A at VI = 0 V; IIH = \u00b12 \u00b5A at VI = VCC). A low level drives the bus dominant; high or open leaves the bus recessive. A dominant time-out (typ. 450 \u00b5s) prevents the bus from being held dominant indefinitely."+        "description": "Transmit data input from the CAN controller. CMOS-level logic input (VIH ≥ 2 V, VIL ≤ 0.8 V) with internal pull-up (IIL = -10 to -50 µA at VI = 0 V; IIH = ±2 µA at VI = VCC). A low level drives the bus dominant; high or open leaves the bus recessive. A dominant time-out (typ. 450 µs) prevents the bus from being held dominant indefinitely."       },       {         "number": "2",@@ -44,37 +44,37 @@         "number": "3",         "name": "VCC",         "type": "power_in",-        "description": "+5 V supply voltage input (recommended 4.5-5.5 V, abs-max -0.3 to +6 V). Typical supply current is ~6 mA in recessive/silent state and ~50 mA (max 70 mA) in dominant state with 60 \u03a9 load."+        "description": "+5 V supply voltage input (recommended 4.5-5.5 V, abs-max -0.3 to +6 V). Typical supply current is ~6 mA in recessive/silent state and ~50 mA (max 70 mA) in dominant state with 60 Ω load."       },       {         "number": "4",         "name": "RXD",         "type": "output",-        "description": "Receive data output to the CAN controller; reads out the differential state of the CAN bus. Push-pull CMOS output (VOH \u2265 4 V at IO = -2 mA, VOL \u2264 0.4 V at IO = 2 mA). LOW = dominant bus, HIGH = recessive bus."+        "description": "Receive data output to the CAN controller; reads out the differential state of the CAN bus. Push-pull CMOS output (VOH ≥ 4 V at IO = -2 mA, VOL ≤ 0.4 V at IO = 2 mA). LOW = dominant bus, HIGH = recessive bus."       },       {         "number": "5",         "name": "Vref",         "type": "output",-        "description": "Reference voltage output at 0.5\u00b7VCC (spec 0.4\u00b7VCC to 0.6\u00b7VCC) capable of sourcing/sinking |IO| \u2264 50 \u00b5A. Provides a stable common-mode reference for the CAN controller or bus termination bias."+        "description": "Reference voltage output at 0.5·VCC (spec 0.4·VCC to 0.6·VCC) capable of sourcing/sinking |IO| ≤ 50 µA. Provides a stable common-mode reference for the CAN controller or bus termination bias."       },       {         "number": "6",         "name": "CANL",         "type": "bidirectional",-        "description": "LOW-level CAN bus line (differential pair with CANH). Driven low (VOL(D) 0.5-2.25 V, typ 1.5 V) in the dominant state and biased to 0.5\u00b7VCC in the recessive state. Handles DC bus voltages of -40 to +40 V and transient \u00b1200 V (see Fig. 7); short-circuit currents are limited by internal protection."+        "description": "LOW-level CAN bus line (differential pair with CANH). Driven low (VOL(D) 0.5-2.25 V, typ 1.5 V) in the dominant state and biased to 0.5·VCC in the recessive state. Handles DC bus voltages of -40 to +40 V and transient ±200 V (see Fig. 7); short-circuit currents are limited by internal protection."       },       {         "number": "7",         "name": "CANH",         "type": "bidirectional",-        "description": "HIGH-level CAN bus line (differential pair with CANL). Driven high (VOH(D) 2.75-4.5 V, typ 3.5 V) in the dominant state and biased to 0.5\u00b7VCC in the recessive state. Handles DC bus voltages of -40 to +40 V and transient \u00b1200 V; internal short-circuit and overcurrent protection."+        "description": "HIGH-level CAN bus line (differential pair with CANL). Driven high (VOH(D) 2.75-4.5 V, typ 3.5 V) in the dominant state and biased to 0.5·VCC in the recessive state. Handles DC bus voltages of -40 to +40 V and transient ±200 V; internal short-circuit and overcurrent protection."       },       {         "number": "8",         "name": "S",         "type": "input",-        "description": "Silent-mode control input (a.k.a. STB). LOW or open = normal (transmitter enabled); HIGH = silent mode (transmitter disabled, receiver still active). VIH \u2265 2.0 V, VIL \u2264 0.8 V; input current 15-60 \u00b5A at VS = 2 V. Enable time from silent to dominant \u2264 1 \u00b5s."+        "description": "Silent-mode control input (a.k.a. STB). LOW or open = normal (transmitter enabled); HIGH = silent mode (transmitter disabled, receiver still active). VIH ≥ 2.0 V, VIL ≤ 0.8 V; input current 15-60 µA at VS = 2 V. Enable time from silent to dominant ≤ 1 µs."       }     ],     "provenance": {@@ -138,5 +138,8 @@     "docs/sit1050t-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file