← Commit history

sit1042aqt: factory component page (tier=lcsc)

Ray ·f04d887bf1 · ·parent 050cb6a
1 file changed +116−8
page.json+116−8
@@ -1,13 +1,126 @@ {+  "schema_version": 1,+  "type": "component",   "slug": "sit1042aqt",+  "title": "SIT1042AQT",+  "brief": "SIT CAN ICs, SOP-8. Datasheet-verified pinout, KiCad symbol/footprint/3D.",   "version": "0.1.0",-  "type": "component",-  "description": "SIT CAN ICs, SOP-8. Datasheet-verified pinout, KiCad symbol/footprint/3D.",+  "license": "CC-BY-SA-4.0",   "tags": [     "component",     "comm-uart",     "sit1042aqt"   ],+  "component": {+    "mpn": "SIT1042AQT",+    "manufacturer": "SIT",+    "package": "SOP-8",+    "pin_count": 8,+    "category": "Comm/UART",+    "subcategory": "CAN ICs",+    "datasheet": "https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2405131100_SIT-SIT1042AQT-3_C5382542.pdf",+    "parts": {+      "symbol": "sit1042aqt.kicad_sym",+      "footprint": "sit1042aqt.kicad_mod",+      "model_3d": "sit1042aqt.glb",+      "model_3d_step": "sit1042aqt.step",+      "lbr": "sit1042aqt.lbr"+    },+    "distributor_links": {},+    "pins": [+      {+        "number": "1",+        "name": "TXD",+        "type": "input",+        "description": "Transmit data input from the CAN controller. Drives the differential bus: logic low = dominant, logic high = recessive. Internal pull-up to VIO (or VCC on non-VIO variants). TXD dominant timeout t_dom_TXD is typically 2 ms (0.8-4 ms), which forces the driver back to recessive if TXD is stuck low."+      },+      {+        "number": "2",+        "name": "GND",+        "type": "power_in",+        "description": "Device ground reference for both the VCC supply and the CAN bus differential outputs."+      },+      {+        "number": "3",+        "name": "VCC",+        "type": "power_in",+        "description": "Main 5V transceiver supply for the CAN bus driver stage. Operating range 4.5-5.5 V. Includes an integrated under-voltage lockout that forces the bus and RXD to the recessive state when VCC is below the UVLO threshold."+      },+      {+        "number": "4",+        "name": "RXD",+        "type": "output",+        "description": "Receive data output to the CAN controller. Drives logic low when the bus is dominant and logic high when recessive. Push-pull output referenced to VIO (or VCC on non-VIO variants); I_OH \u2248 \u22123 mA, I_OL \u2248 5 mA."+      },+      {+        "number": "5",+        "name": "N.C.",+        "type": "unconnected",+        "description": "No internal connection on the SIT1042AQT / SIT1042AQT/1 / SIT1042AQTK / SIT1042AQTK/1 variants (no VIO level-shift supply on these ordering codes). May be left floating or tied to GND. On /3, /31, /K3, /K31 suffix variants this pin is instead the VIO I/O-level supply (1.8-5.5 V region, 2.8-5.5 V spec range) for 3.3 V MCU compatibility."+      },+      {+        "number": "6",+        "name": "CANL",+        "type": "bidirectional",+        "description": "Low-side CAN bus I/O. In the dominant state driven to V_OL(D) \u2248 1.5 V (0.5-2.25 V) into a 60 \u03a9 load; recessive state biased to ~0.5\u00b7VCC. Withstands \u00b158 V bus faults and supports \u221227 V to +32 V common-mode range on the receiver."+      },+      {+        "number": "7",+        "name": "CANH",+        "type": "bidirectional",+        "description": "High-side CAN bus I/O. In the dominant state driven to V_OH(D) \u2248 3.5 V (2.75-4.5 V) into a 60 \u03a9 load; recessive state biased to ~0.5\u00b7VCC. Withstands \u00b158 V bus faults and supports \u221227 V to +32 V common-mode range on the receiver."+      },+      {+        "number": "8",+        "name": "STB",+        "type": "input",+        "description": "Mode-select input: low = high-speed normal mode, high = low-power standby mode with bus wake-up detection. Wake-up time t_WAKE typically 0.5-1.8 \u00b5s, standby-to-normal enable time t_EN \u2264 10 \u00b5s. Internal pull-up to VIO (or VCC) so the device defaults to standby if left floating."+      }+    ],+    "provenance": {+      "extractor": "ds2sf",+      "datasheet": {+        "url": "https://wmsc.lcsc.com/wmsc/upload/file/pdf/v2/lcsc/2405131100_SIT-SIT1042AQT-3_C5382542.pdf",+        "pages": 22,+        "sha256": "07c6ae984de4a519",+        "source_tier": "lcsc"+      },+      "cad": "KiCad official (CC-BY-SA 4.0)",+      "pins": {+        "total": 8,+        "described": 8,+        "cites_pages": true,+        "refuses_to_fabricate": true+      }+    },+    "viewers": {+      "symbol": "viewers/symbol.html",+      "footprint": "viewers/footprint.html"+    }+  },+  "metadata": {+    "specs": {+      "Manufacturer": "SIT",+      "Package": "SOP-8",+      "Category": "Comm/UART",+      "Pins": "8"+    }+  },+  "sections": [+    "hero",+    "viewers",+    "readme",+    "breadcrumbs",+    "info"+  ],+  "discovery_triggers": [+    "sit1042aqt"+  ],+  "discovery_pitch": "SIT1042AQT (SIT) component page with datasheet-verified CAD.",+  "author": {+    "name": "Ray",+    "email": "[email protected]"+  },   "dependencies": {},   "hero": {     "type": "image",@@ -25,10 +138,5 @@     "docs/sit1042aqt-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ],-  "visibility": "public",-  "author": {-    "name": "Ray",-    "email": "[email protected]"-  }+  ] }\ No newline at end of file