component
SIT1042AQT
Public Made by Adomby adom
SIT CAN ICs, SOP-8. Pinout extracted from the datasheet, KiCad symbol/footprint/3D.
← Commit history
page.json+8−5@@ -50,7 +50,7 @@ "number": "4", "name": "RXD", "type": "output",- "description": "Receive data output to the CAN controller. Drives logic low when the bus is dominant and logic high when recessive. Push-pull output referenced to VIO (or VCC on non-VIO variants); I_OH \u2248 \u22123 mA, I_OL \u2248 5 mA."+ "description": "Receive data output to the CAN controller. Drives logic low when the bus is dominant and logic high when recessive. Push-pull output referenced to VIO (or VCC on non-VIO variants); I_OH ≈ −3 mA, I_OL ≈ 5 mA." }, { "number": "5",@@ -62,19 +62,19 @@ "number": "6", "name": "CANL", "type": "bidirectional",- "description": "Low-side CAN bus I/O. In the dominant state driven to V_OL(D) \u2248 1.5 V (0.5-2.25 V) into a 60 \u03a9 load; recessive state biased to ~0.5\u00b7VCC. Withstands \u00b158 V bus faults and supports \u221227 V to +32 V common-mode range on the receiver."+ "description": "Low-side CAN bus I/O. In the dominant state driven to V_OL(D) ≈ 1.5 V (0.5-2.25 V) into a 60 Ω load; recessive state biased to ~0.5·VCC. Withstands ±58 V bus faults and supports −27 V to +32 V common-mode range on the receiver." }, { "number": "7", "name": "CANH", "type": "bidirectional",- "description": "High-side CAN bus I/O. In the dominant state driven to V_OH(D) \u2248 3.5 V (2.75-4.5 V) into a 60 \u03a9 load; recessive state biased to ~0.5\u00b7VCC. Withstands \u00b158 V bus faults and supports \u221227 V to +32 V common-mode range on the receiver."+ "description": "High-side CAN bus I/O. In the dominant state driven to V_OH(D) ≈ 3.5 V (2.75-4.5 V) into a 60 Ω load; recessive state biased to ~0.5·VCC. Withstands ±58 V bus faults and supports −27 V to +32 V common-mode range on the receiver." }, { "number": "8", "name": "STB", "type": "input",- "description": "Mode-select input: low = high-speed normal mode, high = low-power standby mode with bus wake-up detection. Wake-up time t_WAKE typically 0.5-1.8 \u00b5s, standby-to-normal enable time t_EN \u2264 10 \u00b5s. Internal pull-up to VIO (or VCC) so the device defaults to standby if left floating."+ "description": "Mode-select input: low = high-speed normal mode, high = low-power standby mode with bus wake-up detection. Wake-up time t_WAKE typically 0.5-1.8 µs, standby-to-normal enable time t_EN ≤ 10 µs. Internal pull-up to VIO (or VCC) so the device defaults to standby if left floating." } ], "provenance": {@@ -138,5 +138,8 @@ "docs/sit1042aqt-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }