← Commit history

Set visibility: public

Ray ·22f6073e8e · ·parent 2a824fc
1 file changed +10−7
page.json+10−7
@@ -32,7 +32,7 @@         "number": "1",         "name": "TXD",         "type": "input",-        "description": "Transmit data input from the CAN protocol controller. Drives the bus dominant when low and recessive when high. 3.3 V / 5 V logic compatible; VIH \u2265 2 V, VIL \u2264 0.8 V. Internal pull-up leaves TXD in the recessive state when floating (TXD_O = H)."+        "description": "Transmit data input from the CAN protocol controller. Drives the bus dominant when low and recessive when high. 3.3 V / 5 V logic compatible; VIH ≥ 2 V, VIL ≤ 0.8 V. Internal pull-up leaves TXD in the recessive state when floating (TXD_O = H)."       },       {         "number": "2",@@ -50,31 +50,31 @@         "number": "4",         "name": "RXD",         "type": "output",-        "description": "Receive data output to the CAN protocol controller. Reports the bus state: LOW when the bus is dominant, HIGH when recessive. Push-pull output; VOH \u2265 4 V @ IO = -2 mA, VOL \u2264 0.4 V @ IO = 2 mA."+        "description": "Receive data output to the CAN protocol controller. Reports the bus state: LOW when the bus is dominant, HIGH when recessive. Push-pull output; VOH ≥ 4 V @ IO = -2 mA, VOL ≤ 0.4 V @ IO = 2 mA."       },       {         "number": "5",         "name": "SPLIT",         "type": "output",-        "description": "Common-mode stabilization output, nominally VCC/2 (0.3\u00b7VCC to 0.7\u00b7VCC for |IO| < 500 \u00b5A). Intended to be tied to the center tap of a split termination network to stabilize the bus common-mode voltage and improve EMC."+        "description": "Common-mode stabilization output, nominally VCC/2 (0.3·VCC to 0.7·VCC for |IO| < 500 µA). Intended to be tied to the center tap of a split termination network to stabilize the bus common-mode voltage and improve EMC."       },       {         "number": "6",         "name": "CANL",         "type": "bidirectional",-        "description": "Low-level CAN bus line. Driven low in the dominant state and biased to ~VCC/2 in the recessive state. Rated -40 V to +40 V continuous, \u00b1200 V transient; \u00b18 kV HBM ESD."+        "description": "Low-level CAN bus line. Driven low in the dominant state and biased to ~VCC/2 in the recessive state. Rated -40 V to +40 V continuous, ±200 V transient; ±8 kV HBM ESD."       },       {         "number": "7",         "name": "CANH",         "type": "bidirectional",-        "description": "High-level CAN bus line. Driven high in the dominant state and biased to ~VCC/2 in the recessive state. Rated -40 V to +40 V continuous, \u00b1200 V transient; \u00b18 kV HBM ESD."+        "description": "High-level CAN bus line. Driven high in the dominant state and biased to ~VCC/2 in the recessive state. Rated -40 V to +40 V continuous, ±200 V transient; ±8 kV HBM ESD."       },       {         "number": "8",         "name": "STB",         "type": "input",-        "description": "Standby mode control input. STB = 0 selects normal (high-speed) operation; STB = 1 selects low-power standby (~5 \u00b5A typical) with bus wake-up capability. VIH \u2265 2.0 V, VIL \u2264 0.8 V."+        "description": "Standby mode control input. STB = 0 selects normal (high-speed) operation; STB = 1 selects low-power standby (~5 µA typical) with bus wake-up capability. VIH ≥ 2.0 V, VIL ≤ 0.8 V."       }     ],     "provenance": {@@ -138,5 +138,8 @@     "docs/sit1040t-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file