← Commit history

si1902cdl-t1-ge3: specified limits as data (metadata.characteristics, 50 rows from the datasheet)

Ray ·1ad4218ca5 ·24d ago ·parent cf7231d
2 files changed +665−1
README.md+57
@@ -24,6 +24,63 @@ SI1902CDL-T1-GE3 from Vishay Intertech, in a SC-70-6. Pinout and pin description | Category | Transistors/Thyristors | | Pins | 6 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Drain-source voltage | VDS |  |  | 20 | V |  | 1 |+| Gate-source voltage | VGS | -12 |  | 12 | V |  | 1 |+| Continuous drain current | ID |  |  | 1.1 | A | TJ = 150 °C, TC = 25 °C | 1 |+| Continuous drain current | ID |  |  | 0.9 | A | TJ = 150 °C, TC = 70 °C | 1 |+| Continuous drain current | ID |  |  | 1 | A | TJ = 150 °C, TA = 25 °C | 1 |+| Continuous drain current | ID |  |  | 0.8 | A | TJ = 150 °C, TA = 70 °C | 1 |+| Pulsed drain current | IDM |  |  | 2 | A | t = 300 μs | 1 |+| Continuous source-drain diode current | IS |  |  | 0.35 | A | TC = 25 °C | 1 |+| Continuous source-drain diode current | IS |  |  | 0.25 | A | TA = 25 °C | 1 |+| Maximum power dissipation | PD |  |  | 0.42 | W | TC = 25 °C | 1 |+| Maximum power dissipation | PD |  |  | 0.27 | W | TC = 70 °C | 1 |+| Maximum power dissipation | PD |  |  | 0.3 | W | TA = 25 °C | 1 |+| Maximum power dissipation | PD |  |  | 0.23 | W | TA = 70 °C | 1 |+| Operating junction and storage temperature range | TJ, Tstg | -55 |  | 150 | °C |  | 1 |+| Maximum junction-to-ambient | RthJA |  | 290 | 350 | °C/W | t ≤ 5 s | 1 |+| Maximum junction-to-foot (drain) | RthJF |  | 250 | 300 | °C/W | Steady state | 1 |+| Drain-source breakdown voltage | VDS | 20 |  |  | V | VGS = 0 V, ID = 250 μA | 2 |+| Gate-source threshold voltage | VGS(th) | 0.6 |  | 1.5 | V | VDS = VGS, ID = 250 μA | 2 |+| Gate-source leakage | IGSS | -100 |  | 100 | nA | VDS = 0 V, VGS = ± 12 V | 2 |+| Zero gate voltage drain current | IDSS |  |  | 1 | μA | VDS = 20 V, VGS = 0 V | 2 |+| Zero gate voltage drain current | IDSS |  |  | 10 | μA | VDS = 20 V, VGS = 0 V, TJ = 85 °C | 2 |+| On-state drain current | ID(on) | 2 |  |  | A | VDS ≥ 5 V, VGS = 4.5 V | 2 |+| Drain-source on-state resistance | RDS(on) |  | 0.195 | 0.235 | Ω | VGS = 4.5 V, ID = 1 A | 2 |+| Drain-source on-state resistance | RDS(on) |  | 0.255 | 0.306 | Ω | VGS = 2.5 V, ID = 0.3 A | 2 |+| Total gate charge | Qg |  | 2 | 3 | nC | VDS = 10 V, VGS = 10 V, ID = 1 A | 2 |+| Total gate charge | Qg |  | 0.9 | 1.4 | nC | VDS = 10 V, VGS = 4.5 V, ID = 1 A | 2 |+| Gate resistance | Rg | 2.4 | 12 | 24 | Ω | f = 1 MHz | 2 |+| Turn-on delay time | td(on) |  | 4 | 8 | ns | VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 10 V, Rg = 1 Ω | 2 |+| Rise time | tr |  | 13 | 20 | ns | VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 10 V, Rg = 1 Ω | 2 |+| Turn-off delay time | td(off) |  | 11 | 20 | ns | VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 10 V, Rg = 1 Ω | 2 |+| Fall time | tf |  | 9 | 18 | ns | VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 10 V, Rg = 1 Ω | 2 |+| Turn-on delay time | td(on) |  | 6 | 12 | ns | VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 4.5 V, Rg = 1 Ω | 2 |+| Rise time | tr |  | 16 | 24 | ns | VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 4.5 V, Rg = 1 Ω | 2 |+| Turn-off delay time | td(off) |  | 13 | 20 | ns | VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 4.5 V, Rg = 1 Ω | 2 |+| Fall time | tf |  | 10 | 20 | ns | VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 4.5 V, Rg = 1 Ω | 2 |+| Continuous source-drain diode current | IS |  |  | 0.35 | A | TC = 25 °C | 2 |+| Pulse diode forward current | ISM |  |  | 2 | A |  | 2 |+| Body diode voltage | VSD |  | 0.8 | 1.2 | V | IS = 0.8 A | 2 |+| Body diode reverse recovery time | trr |  | 2 | 4 | nC | IF = 0.8 A, di/dt = 100 A/μs | 2 |+| Body diode reverse recovery charge | Qrr |  | 8 | 16 | nC | IF = 0.8 A, di/dt = 100 A/μs | 2 |+| VDS temperature coefficient | VDS/TJ |  | 25 |  | mV/°C | ID = 250 μA | 2 |+| VGS(th) temperature coefficient | VGS(th)/TJ |  | -2.6 |  | mV/°C |  | 2 |+| Forward transconductance | gfs |  | 3 |  | ms | VDS = 10 V, ID = 1 A | 2 |+| Input capacitance | Ciss |  | 62 |  | pF | VDS = 10 V, VGS = 0 V, f = 1 MHz | 2 |+| Output capacitance | Coss |  | 20 |  | pF | VDS = 10 V, VGS = 0 V, f = 1 MHz | 2 |+| Reverse transfer capacitance | Crss |  | 7 |  | pF | VDS = 10 V, VGS = 0 V, f = 1 MHz | 2 |+| Gate-source charge | Qgs |  | 0.2 |  | nC |  | 2 |+| Gate-drain charge | Qgd |  | 0.2 |  | nC |  | 2 |+| Reverse recovery fall time | ta |  | 5 |  | ns |  | 2 |+| Reverse recovery rise time | tb |  | 3 |  | ns |  | 2 |+ ## CAD (KiCad official)  - Symbol: `SI1902CDL-T1-GE3`
page.json+608−1
@@ -168,6 +168,613 @@       "Package": "SC-70-6",       "Category": "Transistors/Thyristors",       "Pins": "6"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "2c9a5d8705ab96d6",+      "rows": [+        {+          "name": "Drain-source voltage",+          "symbol": "VDS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Gate-source voltage",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -12,+          "typ": null,+          "max": 12,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous drain current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 1.1,+          "conditions": "TJ = 150 °C, TC = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous drain current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.9,+          "conditions": "TJ = 150 °C, TC = 70 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous drain current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "TJ = 150 °C, TA = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous drain current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.8,+          "conditions": "TJ = 150 °C, TA = 70 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Pulsed drain current",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "t = 300 μs",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous source-drain diode current",+          "symbol": "IS",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.35,+          "conditions": "TC = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous source-drain diode current",+          "symbol": "IS",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.25,+          "conditions": "TA = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum power dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.42,+          "conditions": "TC = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum power dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.27,+          "conditions": "TC = 70 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum power dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.3,+          "conditions": "TA = 25 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum power dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.23,+          "conditions": "TA = 70 °C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Operating junction and storage temperature range",+          "symbol": "TJ, Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum junction-to-ambient",+          "symbol": "RthJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 290,+          "max": 350,+          "conditions": "t ≤ 5 s",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum junction-to-foot (drain)",+          "symbol": "RthJF",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 250,+          "max": 300,+          "conditions": "Steady state",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Drain-source breakdown voltage",+          "symbol": "VDS",+          "kind": "electrical",+          "unit": "V",+          "min": 20,+          "typ": null,+          "max": null,+          "conditions": "VGS = 0 V, ID = 250 μA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-source threshold voltage",+          "symbol": "VGS(th)",+          "kind": "electrical",+          "unit": "V",+          "min": 0.6,+          "typ": null,+          "max": 1.5,+          "conditions": "VDS = VGS, ID = 250 μA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-source leakage",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "nA",+          "min": -100,+          "typ": null,+          "max": 100,+          "conditions": "VDS = 0 V, VGS = ± 12 V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Zero gate voltage drain current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VDS = 20 V, VGS = 0 V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Zero gate voltage drain current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "VDS = 20 V, VGS = 0 V, TJ = 85 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "On-state drain current",+          "symbol": "ID(on)",+          "kind": "electrical",+          "unit": "A",+          "min": 2,+          "typ": null,+          "max": null,+          "conditions": "VDS ≥ 5 V, VGS = 4.5 V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-source on-state resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.195,+          "max": 0.235,+          "conditions": "VGS = 4.5 V, ID = 1 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-source on-state resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.255,+          "max": 0.306,+          "conditions": "VGS = 2.5 V, ID = 0.3 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total gate charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 2,+          "max": 3,+          "conditions": "VDS = 10 V, VGS = 10 V, ID = 1 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total gate charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 0.9,+          "max": 1.4,+          "conditions": "VDS = 10 V, VGS = 4.5 V, ID = 1 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate resistance",+          "symbol": "Rg",+          "kind": "electrical",+          "unit": "Ω",+          "min": 2.4,+          "typ": 12,+          "max": 24,+          "conditions": "f = 1 MHz",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-on delay time",+          "symbol": "td(on)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 4,+          "max": 8,+          "conditions": "VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 10 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rise time",+          "symbol": "tr",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 13,+          "max": 20,+          "conditions": "VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 10 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-off delay time",+          "symbol": "td(off)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 11,+          "max": 20,+          "conditions": "VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 10 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Fall time",+          "symbol": "tf",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 9,+          "max": 18,+          "conditions": "VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 10 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-on delay time",+          "symbol": "td(on)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 6,+          "max": 12,+          "conditions": "VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 4.5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rise time",+          "symbol": "tr",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 16,+          "max": 24,+          "conditions": "VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 4.5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-off delay time",+          "symbol": "td(off)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 13,+          "max": 20,+          "conditions": "VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 4.5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Fall time",+          "symbol": "tf",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 10,+          "max": 20,+          "conditions": "VDD = 10 V, RL = 12.5 Ω, ID 0.8 A, VGEN = 4.5 V, Rg = 1 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Continuous source-drain diode current",+          "symbol": "IS",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.35,+          "conditions": "TC = 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Pulse diode forward current",+          "symbol": "ISM",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 2,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Body diode voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 0.8,+          "max": 1.2,+          "conditions": "IS = 0.8 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Body diode reverse recovery time",+          "symbol": "trr",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 2,+          "max": 4,+          "conditions": "IF = 0.8 A, di/dt = 100 A/μs",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Body diode reverse recovery charge",+          "symbol": "Qrr",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 8,+          "max": 16,+          "conditions": "IF = 0.8 A, di/dt = 100 A/μs",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "VDS temperature coefficient",+          "symbol": "VDS/TJ",+          "kind": "temperature_coefficient",+          "unit": "mV/°C",+          "min": null,+          "typ": 25,+          "max": null,+          "conditions": "ID = 250 μA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "VGS(th) temperature coefficient",+          "symbol": "VGS(th)/TJ",+          "kind": "temperature_coefficient",+          "unit": "mV/°C",+          "min": null,+          "typ": -2.6,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Forward transconductance",+          "symbol": "gfs",+          "kind": "electrical",+          "unit": "ms",+          "min": null,+          "typ": 3,+          "max": null,+          "conditions": "VDS = 10 V, ID = 1 A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input capacitance",+          "symbol": "Ciss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 62,+          "max": null,+          "conditions": "VDS = 10 V, VGS = 0 V, f = 1 MHz",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output capacitance",+          "symbol": "Coss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 20,+          "max": null,+          "conditions": "VDS = 10 V, VGS = 0 V, f = 1 MHz",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse transfer capacitance",+          "symbol": "Crss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 7,+          "max": null,+          "conditions": "VDS = 10 V, VGS = 0 V, f = 1 MHz",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-source charge",+          "symbol": "Qgs",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 0.2,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-drain charge",+          "symbol": "Qgd",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 0.2,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse recovery fall time",+          "symbol": "ta",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 5,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse recovery rise time",+          "symbol": "tb",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 3,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -209,4 +816,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}