← Commit history

sgm5018yts: restore the component block (pinout + model declarations) from this page's own README and symbol

Ray ·9f9bdbbc8b · ·parent 9d4de9f
1 file changed +122−1
page.json+122−1
@@ -33,5 +33,126 @@   "author": {     "name": "Ray",     "email": "[email protected]"+  },+  "component": {+    "mpn": "SGM5018YTS",+    "manufacturer": "SGMICRO",+    "package": "TSSOP-16",+    "pin_count": 16,+    "category": "Analog Switches, Multiplexers",+    "parts": {+      "symbol": "sgm5018yts.kicad_sym",+      "footprint": "sgm5018yts.kicad_mod",+      "model_3d": "sgm5018yts-etched.glb",+      "model_3d_plain": "sgm5018yts.glb",+      "model_3d_step": "sgm5018yts-etched.step",+      "model_3d_step_plain": "sgm5018yts.step",+      "lbr": "sgm5018yts.lbr"+    },+    "pins": [+      {+        "number": "1",+        "name": "IN",+        "type": "input",+        "description": "Digital control input. Selects whether COMx pins connect to NOx (IN = high) or NCx (IN = low) when EN is low. TTL/CMOS compatible; VIH = 1.6 V, VIL = 0.5 V at V+ = 4.5-5.5 V (VIL = 0.4 V at V+ = 2.7-3.6 V)."+      },+      {+        "number": "2",+        "name": "NC1",+        "type": "passive",+        "description": "Channel 1 Normally Closed switch terminal. Analog signal range 0 V to V+; continuous current on NO/NC/COM limited to ±100 mA. Connected to COM1 when EN = low and IN = low."+      },+      {+        "number": "3",+        "name": "NO1",+        "type": "passive",+        "description": "Channel 1 Normally Open switch terminal. Analog signal range 0 V to V+; continuous current on NO/NC/COM limited to ±100 mA. Connected to COM1 when EN = low and IN = high."+      },+      {+        "number": "4",+        "name": "COM1",+        "type": "passive",+        "description": "Channel 1 Common switch pole. Routes to NO1 or NC1 depending on IN state (with EN = low). Typical on-resistance 4.5 Ω at V+ = 4.5 V, ±100 mA."+      },+      {+        "number": "5",+        "name": "NC2",+        "type": "passive",+        "description": "Channel 2 Normally Closed switch terminal. Analog signal range 0 V to V+; continuous current on NO/NC/COM limited to ±100 mA. Connected to COM2 when EN = low and IN = low."+      },+      {+        "number": "6",+        "name": "NO2",+        "type": "passive",+        "description": "Channel 2 Normally Open switch terminal. Analog signal range 0 V to V+; continuous current on NO/NC/COM limited to ±100 mA. Connected to COM2 when EN = low and IN = high."+      },+      {+        "number": "7",+        "name": "COM2",+        "type": "passive",+        "description": "Channel 2 Common switch pole. Routes to NO2 or NC2 depending on IN state (with EN = low). Typical on-resistance 4.5 Ω at V+ = 4.5 V, ±100 mA."+      },+      {+        "number": "8",+        "name": "GND",+        "type": "power_in",+        "description": "Ground reference for the device. Analog signals on NO/NC/COM are referenced to GND; V+ is measured relative to GND (-0.3 V to +6 V absolute maximum)."+      },+      {+        "number": "9",+        "name": "COM3",+        "type": "passive",+        "description": "Channel 3 Common switch pole. Routes to NO3 or NC3 depending on IN state (with EN = low). Typical on-resistance 4.5 Ω at V+ = 4.5 V, ±100 mA."+      },+      {+        "number": "10",+        "name": "NO3",+        "type": "passive",+        "description": "Channel 3 Normally Open switch terminal. Analog signal range 0 V to V+; continuous current on NO/NC/COM limited to ±100 mA. Connected to COM3 when EN = low and IN = high."+      },+      {+        "number": "11",+        "name": "NC3",+        "type": "passive",+        "description": "Channel 3 Normally Closed switch terminal. Analog signal range 0 V to V+; continuous current on NO/NC/COM limited to ±100 mA. Connected to COM3 when EN = low and IN = low."+      },+      {+        "number": "12",+        "name": "COM4",+        "type": "passive",+        "description": "Channel 4 Common switch pole. Routes to NO4 or NC4 depending on IN state (with EN = low). Typical on-resistance 4.5 Ω at V+ = 4.5 V, ±100 mA."+      },+      {+        "number": "13",+        "name": "NO4",+        "type": "passive",+        "description": "Channel 4 Normally Open switch terminal. Analog signal range 0 V to V+; continuous current on NO/NC/COM limited to ±100 mA. Connected to COM4 when EN = low and IN = high."+      },+      {+        "number": "14",+        "name": "NC4",+        "type": "passive",+        "description": "Channel 4 Normally Closed switch terminal. Analog signal range 0 V to V+; continuous current on NO/NC/COM limited to ±100 mA. Connected to COM4 when EN = low and IN = low."+      },+      {+        "number": "15",+        "name": "EN",+        "type": "input",+        "description": "Digital enable control (active-low). Normally connect to GND for switch operation; drive to logic high to force all four switches OFF (all NO/NC disconnected from COM). TTL/CMOS compatible."+      },+      {+        "number": "16",+        "name": "V+",+        "type": "power_in",+        "description": "Positive power supply, 1.8 V to 5.5 V single supply. Absolute maximum 6 V referenced to GND. Supply current typically <1 µA. Bypass with 0.1 µF to GND."+      }+    ],+    "provenance": {+      "rebuilt": "component block rebuilt 2026-10-05 from this page's own README pinout table and .kicad_sym (pins cross-checked), no re-extraction"+    },+    "viewers": {+      "symbol": "viewers/symbol.html",+      "footprint": "viewers/footprint.html"+    }   }-}\ No newline at end of file+}