← Commit history
page.json+8−5@@ -38,7 +38,7 @@ "number": "2", "name": "PROG", "type": "passive",- "description": "Charge-current program and monitor pin. A resistor R_PROG from PROG to GND sets the constant charge current (I_BAT = 1000/R_PROG, giving 1A at R_PROG = 1k\u03a9). Pin sits at ~1.0V in current mode; C/10 termination is detected when PROG drops below ~100mV."+ "description": "Charge-current program and monitor pin. A resistor R_PROG from PROG to GND sets the constant charge current (I_BAT = 1000/R_PROG, giving 1A at R_PROG = 1kΩ). Pin sits at ~1.0V in current mode; C/10 termination is detected when PROG drops below ~100mV." }, { "number": "3",@@ -56,19 +56,19 @@ "number": "5", "name": "BAT", "type": "power_out",- "description": "Battery connection. Charging current is delivered through this pin from the internal PMOS pass device; float voltage is 4.2V (A suffix) or 4.35V (C suffix) with \u00b11% accuracy, and IBAT can reach 1A. Absolute max 11V; drives <2uA leakage into the battery when VCC is removed."+ "description": "Battery connection. Charging current is delivered through this pin from the internal PMOS pass device; float voltage is 4.2V (A suffix) or 4.35V (C suffix) with ±1% accuracy, and IBAT can reach 1A. Absolute max 11V; drives <2uA leakage into the battery when VCC is removed." }, { "number": "6", "name": "STDBY", "type": "output",- "description": "Charge-complete indicator (open-drain). Pulled low when the charge cycle has terminated (C/10 detected); high-impedance in all other states. Vol \u2264 0.4V at 5mA sink."+ "description": "Charge-complete indicator (open-drain). Pulled low when the charge cycle has terminated (C/10 detected); high-impedance in all other states. Vol ≤ 0.4V at 5mA sink." }, { "number": "7", "name": "CHRG", "type": "output",- "description": "Charge-in-progress indicator (open-drain). Pulled low while the charger is actively delivering current; high-impedance otherwise. Flashes at ~1-4s when a fault (missing battery) is detected with a 10uF cap at BAT. Vol \u2264 0.4V at 5mA sink."+ "description": "Charge-in-progress indicator (open-drain). Pulled low while the charger is actively delivering current; high-impedance otherwise. Flashes at ~1-4s when a fault (missing battery) is detected with a 10uF cap at BAT. Vol ≤ 0.4V at 5mA sink." }, { "number": "8",@@ -138,5 +138,8 @@ "docs/se9450-hf-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }