← Commit history

Set visibility: public

Ray ·9905300e83 · ·parent 7a1a4ff
1 file changed +10−7
page.json+10−7
@@ -44,37 +44,37 @@         "number": "3",         "name": "TXD",         "type": "input",-        "description": "UART transmit data input from host MCU. 5V logic (VIH \u2265 0.7\u00b7VCC, VIL \u2264 0.3\u00b7VCC). Internal 10 k\u03a9 pull-up; drive current 2 mA. Data on TXD is transmitted onto the A/B bus when CON is low."+        "description": "UART transmit data input from host MCU. 5V logic (VIH ≥ 0.7·VCC, VIL ≤ 0.3·VCC). Internal 10 kΩ pull-up; drive current 2 mA. Data on TXD is transmitted onto the A/B bus when CON is low."       },       {         "number": "4",         "name": "RXD",         "type": "output",-        "description": "UART receive data output to host MCU. Push-pull output (VOH \u2265 VCC-0.4 V, VOL \u2264 0.4 V at 4 mA), max output current 10 mA. Reflects the A/B bus differential state when CON is high."+        "description": "UART receive data output to host MCU. Push-pull output (VOH ≥ VCC-0.4 V, VOL ≤ 0.4 V at 4 mA), max output current 10 mA. Reflects the A/B bus differential state when CON is high."       },       {         "number": "5",         "name": "CON",         "type": "input",-        "description": "Transmit/receive direction control. CON=0 (low) \u2192 transmit mode (drives A/B from TXD); CON=1 (high) \u2192 receive mode (drives RXD from A/B). Note: polarity is inverted from a standard RS-485 transceiver's DE/RE. VIH \u2265 3.8V (RSM485CT), VIL \u2264 0.3\u00b7VCC. Drive current 5 mA."+        "description": "Transmit/receive direction control. CON=0 (low) → transmit mode (drives A/B from TXD); CON=1 (high) → receive mode (drives RXD from A/B). Note: polarity is inverted from a standard RS-485 transceiver's DE/RE. VIH ≥ 3.8V (RSM485CT), VIL ≤ 0.3·VCC. Drive current 5 mA."       },       {         "number": "8",         "name": "B",         "type": "bidirectional",-        "description": "RS-485 differential bus line B (inverting). Internally biased with 22 k\u03a9 pull-down/up network; integrated ESD protection. Differential output voltage |A-B| \u2265 1.5V into 54\u03a9 load; input impedance \u2265 96 k\u03a9 over -7V \u2264 VCM \u2264 +12V."+        "description": "RS-485 differential bus line B (inverting). Internally biased with 22 kΩ pull-down/up network; integrated ESD protection. Differential output voltage |A-B| ≥ 1.5V into 54Ω load; input impedance ≥ 96 kΩ over -7V ≤ VCM ≤ +12V."       },       {         "number": "9",         "name": "A",         "type": "bidirectional",-        "description": "RS-485 differential bus line A (non-inverting). Internally biased with 22 k\u03a9 pull-down/up network; integrated ESD protection. Paired with B to form the isolated RS-485 differential bus."+        "description": "RS-485 differential bus line A (non-inverting). Internally biased with 22 kΩ pull-down/up network; integrated ESD protection. Paired with B to form the isolated RS-485 differential bus."       },       {         "number": "10",         "name": "RGND",         "type": "power_out",-        "description": "Isolated output-side ground (secondary side reference for the A/B RS-485 bus). Galvanically isolated from GND (pin 2) by 2.5 kVDC. May be left floating if not used; in noisy environments connect to cable shield / earth through impedance network per \u00a79.5."+        "description": "Isolated output-side ground (secondary side reference for the A/B RS-485 bus). Galvanically isolated from GND (pin 2) by 2.5 kVDC. May be left floating if not used; in noisy environments connect to cable shield / earth through impedance network per §9.5."       }     ],     "provenance": {@@ -148,5 +148,8 @@     "docs/rsm485ct-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file