← Commit history

Set visibility: public

Ray ·335cdcaf4f · ·parent a0d9f54
1 file changed +12−9
page.json+12−9
@@ -44,7 +44,7 @@         "number": "3",         "name": "TXD1",         "type": "input",-        "description": "UART transmit input for RS-485 channel 1. Logic level referenced to VCC: VIH >= 0.7*VCC, VIL <= 0.3*VCC. Internal 10k\u03a9 pull-up to VCC. Drive current 2mA. Data drives the A1/B1 differential outputs (TXD=1 -> A1=1, B1=0)."+        "description": "UART transmit input for RS-485 channel 1. Logic level referenced to VCC: VIH >= 0.7*VCC, VIL <= 0.3*VCC. Internal 10kΩ pull-up to VCC. Drive current 2mA. Data drives the A1/B1 differential outputs (TXD=1 -> A1=1, B1=0)."       },       {         "number": "4",@@ -56,7 +56,7 @@         "number": "5",         "name": "TXD2",         "type": "input",-        "description": "UART transmit input for RS-485 channel 2. Same logic-level characteristics as TXD1 (VIH >= 0.7*VCC, VIL <= 0.3*VCC, 10k\u03a9 internal pull-up, 2mA drive). Drives the A2/B2 differential outputs. (Datasheet description reads '\u53d1\u9001\u811a 1' - labelled as channel 2 by pin name.)"+        "description": "UART transmit input for RS-485 channel 2. Same logic-level characteristics as TXD1 (VIH >= 0.7*VCC, VIL <= 0.3*VCC, 10kΩ internal pull-up, 2mA drive). Drives the A2/B2 differential outputs. (Datasheet description reads '发送脚 1' - labelled as channel 2 by pin name.)"       },       {         "number": "6",@@ -68,37 +68,37 @@         "number": "7",         "name": "A2",         "type": "bidirectional",-        "description": "RS-485 channel 2 non-inverting differential I/O (bus A). Includes integrated ~4.7k\u03a9 pull-up bias, ESD protection, and 48k\u03a9 input impedance (-7V to +12V common mode). Differential output |VOD| >= 1.5V into 54\u03a9 load."+        "description": "RS-485 channel 2 non-inverting differential I/O (bus A). Includes integrated ~4.7kΩ pull-up bias, ESD protection, and 48kΩ input impedance (-7V to +12V common mode). Differential output |VOD| >= 1.5V into 54Ω load."       },       {         "number": "8",         "name": "B2",         "type": "bidirectional",-        "description": "RS-485 channel 2 inverting differential I/O (bus B). Integrated ~4.7k\u03a9 pull-down bias and ESD protection. Companion to A2 for the isolated RS-485 channel 2 bus."+        "description": "RS-485 channel 2 inverting differential I/O (bus B). Integrated ~4.7kΩ pull-down bias and ESD protection. Companion to A2 for the isolated RS-485 channel 2 bus."       },       {         "number": "9",         "name": "G2",         "type": "power_out",-        "description": "Isolated power/return ground for RS-485 channel 2 bus (secondary side of channel 2). Isolated 2500VDC from the primary GND and from G1. Datasheet \u00a78.3 notes this pin may be left floating if not used."+        "description": "Isolated power/return ground for RS-485 channel 2 bus (secondary side of channel 2). Isolated 2500VDC from the primary GND and from G1. Datasheet §8.3 notes this pin may be left floating if not used."       },       {         "number": "10",         "name": "A1",         "type": "bidirectional",-        "description": "RS-485 channel 1 non-inverting differential I/O (bus A). Includes integrated ~4.7k\u03a9 pull-up bias, ESD protection, and 48k\u03a9 input impedance (-7V to +12V common mode). Differential output |VOD| >= 1.5V into 54\u03a9 load."+        "description": "RS-485 channel 1 non-inverting differential I/O (bus A). Includes integrated ~4.7kΩ pull-up bias, ESD protection, and 48kΩ input impedance (-7V to +12V common mode). Differential output |VOD| >= 1.5V into 54Ω load."       },       {         "number": "11",         "name": "B1",         "type": "bidirectional",-        "description": "RS-485 channel 1 inverting differential I/O (bus B). Integrated ~4.7k\u03a9 pull-down bias and ESD protection. Companion to A1 for the isolated RS-485 channel 1 bus."+        "description": "RS-485 channel 1 inverting differential I/O (bus B). Integrated ~4.7kΩ pull-down bias and ESD protection. Companion to A1 for the isolated RS-485 channel 1 bus."       },       {         "number": "12",         "name": "G1",         "type": "power_out",-        "description": "Isolated power/return ground for RS-485 channel 1 bus (secondary side of channel 1). Isolated 2500VDC from the primary GND and from G2. Per \u00a78.3 may be left floating if not used."+        "description": "Isolated power/return ground for RS-485 channel 1 bus (secondary side of channel 1). Isolated 2500VDC from the primary GND and from G2. Per §8.3 may be left floating if not used."       }     ],     "provenance": {@@ -172,5 +172,8 @@     "docs/rsm3485idht-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file