← Commit history

Set visibility: public

Ray ·f42078d11a ·1mo ago ·parent f92ade8
1 file changed +9−6
page.json+9−6
@@ -32,13 +32,13 @@         "number": "1",         "name": "IN",         "type": "input",-        "description": "Digital control input, TTL/CMOS compatible. Selects switch state: logic 0 turns NO OFF and NC ON; logic 1 turns NO ON and NC OFF. V_IH \u2265 1.5 V @ 5 V (1.3 V @ 3.3 V); V_IL \u2264 0.6 V @ 5 V (0.5 V @ 3.3 V). Input leakage \u2264 1 \u00b5A. Must not be left floating."+        "description": "Digital control input, TTL/CMOS compatible. Selects switch state: logic 0 turns NO OFF and NC ON; logic 1 turns NO ON and NC OFF. V_IH ≥ 1.5 V @ 5 V (1.3 V @ 3.3 V); V_IL ≤ 0.6 V @ 5 V (0.5 V @ 3.3 V). Input leakage ≤ 1 µA. Must not be left floating."       },       {         "number": "2",         "name": "V+",         "type": "power_in",-        "description": "Positive power supply, 1.8 V to 5.5 V. Absolute max V+ to GND is -0.3 V to 7.0 V. Supply current \u2264 1 \u00b5A. Bypass to GND with a local decoupling capacitor."+        "description": "Positive power supply, 1.8 V to 5.5 V. Absolute max V+ to GND is -0.3 V to 7.0 V. Supply current ≤ 1 µA. Bypass to GND with a local decoupling capacitor."       },       {         "number": "3",@@ -50,19 +50,19 @@         "number": "4",         "name": "NC",         "type": "passive",-        "description": "Normally-Closed switch terminal (analog signal). Connected to COM when IN = 0. Signal range 0 V to V+, R_ON \u2248 0.6 \u03a9 (typ) at 5 V, continuous current \u00b1500 mA (peak \u00b1800 mA). Bidirectional analog/digital signal path."+        "description": "Normally-Closed switch terminal (analog signal). Connected to COM when IN = 0. Signal range 0 V to V+, R_ON ≈ 0.6 Ω (typ) at 5 V, continuous current ±500 mA (peak ±800 mA). Bidirectional analog/digital signal path."       },       {         "number": "5",         "name": "COM",         "type": "passive",-        "description": "Common (pole) terminal of the SPDT switch. Routed to NC when IN = 0 and to NO when IN = 1. Signal range 0 V to V+, R_ON \u2248 0.6 \u03a9 (typ), \u00b1500 mA continuous."+        "description": "Common (pole) terminal of the SPDT switch. Routed to NC when IN = 0 and to NO when IN = 1. Signal range 0 V to V+, R_ON ≈ 0.6 Ω (typ), ±500 mA continuous."       },       {         "number": "6",         "name": "NO",         "type": "passive",-        "description": "Normally-Open switch terminal (analog signal). Connected to COM when IN = 1. Signal range 0 V to V+, R_ON \u2248 0.6 \u03a9 (typ), \u00b1500 mA continuous. Bidirectional analog/digital signal path."+        "description": "Normally-Open switch terminal (analog signal). Connected to COM when IN = 1. Signal range 0 V to V+, R_ON ≈ 0.6 Ω (typ), ±500 mA continuous. Bidirectional analog/digital signal path."       }     ],     "provenance": {@@ -126,5 +126,8 @@     "docs/rs2103xh-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file