component
RS2103XH
Public Made by Adomby adom
Jiangsu RUNIC Tech Analog Switches, Multiplexers, SOT-23-6. Pinout extracted from the datasheet, KiCad symbol/footprint/3D.
← Commit history
page.json+9−6@@ -32,13 +32,13 @@ "number": "1", "name": "IN", "type": "input",- "description": "Digital control input, TTL/CMOS compatible. Selects switch state: logic 0 turns NO OFF and NC ON; logic 1 turns NO ON and NC OFF. V_IH \u2265 1.5 V @ 5 V (1.3 V @ 3.3 V); V_IL \u2264 0.6 V @ 5 V (0.5 V @ 3.3 V). Input leakage \u2264 1 \u00b5A. Must not be left floating."+ "description": "Digital control input, TTL/CMOS compatible. Selects switch state: logic 0 turns NO OFF and NC ON; logic 1 turns NO ON and NC OFF. V_IH ≥ 1.5 V @ 5 V (1.3 V @ 3.3 V); V_IL ≤ 0.6 V @ 5 V (0.5 V @ 3.3 V). Input leakage ≤ 1 µA. Must not be left floating." }, { "number": "2", "name": "V+", "type": "power_in",- "description": "Positive power supply, 1.8 V to 5.5 V. Absolute max V+ to GND is -0.3 V to 7.0 V. Supply current \u2264 1 \u00b5A. Bypass to GND with a local decoupling capacitor."+ "description": "Positive power supply, 1.8 V to 5.5 V. Absolute max V+ to GND is -0.3 V to 7.0 V. Supply current ≤ 1 µA. Bypass to GND with a local decoupling capacitor." }, { "number": "3",@@ -50,19 +50,19 @@ "number": "4", "name": "NC", "type": "passive",- "description": "Normally-Closed switch terminal (analog signal). Connected to COM when IN = 0. Signal range 0 V to V+, R_ON \u2248 0.6 \u03a9 (typ) at 5 V, continuous current \u00b1500 mA (peak \u00b1800 mA). Bidirectional analog/digital signal path."+ "description": "Normally-Closed switch terminal (analog signal). Connected to COM when IN = 0. Signal range 0 V to V+, R_ON ≈ 0.6 Ω (typ) at 5 V, continuous current ±500 mA (peak ±800 mA). Bidirectional analog/digital signal path." }, { "number": "5", "name": "COM", "type": "passive",- "description": "Common (pole) terminal of the SPDT switch. Routed to NC when IN = 0 and to NO when IN = 1. Signal range 0 V to V+, R_ON \u2248 0.6 \u03a9 (typ), \u00b1500 mA continuous."+ "description": "Common (pole) terminal of the SPDT switch. Routed to NC when IN = 0 and to NO when IN = 1. Signal range 0 V to V+, R_ON ≈ 0.6 Ω (typ), ±500 mA continuous." }, { "number": "6", "name": "NO", "type": "passive",- "description": "Normally-Open switch terminal (analog signal). Connected to COM when IN = 1. Signal range 0 V to V+, R_ON \u2248 0.6 \u03a9 (typ), \u00b1500 mA continuous. Bidirectional analog/digital signal path."+ "description": "Normally-Open switch terminal (analog signal). Connected to COM when IN = 1. Signal range 0 V to V+, R_ON ≈ 0.6 Ω (typ), ±500 mA continuous. Bidirectional analog/digital signal path." } ], "provenance": {@@ -126,5 +126,8 @@ "docs/rs2103xh-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }