← Commit history

Set visibility: public

Ray ·57b5939c2b ·1mo ago ·parent c304f32
1 file changed +9−6
page.json+9−6
@@ -32,13 +32,13 @@         "number": "1",         "name": "IN",         "type": "input",-        "description": "Digital control input. TTL/CMOS-compatible logic pin selecting the switch position: logic 0 = NO OFF / NC ON, logic 1 = NO ON / NC OFF. VINH \u2265 1.5 V @ V+=5 V (1 V @ 3.3 V); VINL \u2264 0.6 V @ V+=5 V (0.5 V @ 3.3 V). Input leakage 1 \u03bcA max."+        "description": "Digital control input. TTL/CMOS-compatible logic pin selecting the switch position: logic 0 = NO OFF / NC ON, logic 1 = NO ON / NC OFF. VINH ≥ 1.5 V @ V+=5 V (1 V @ 3.3 V); VINL ≤ 0.6 V @ V+=5 V (0.5 V @ 3.3 V). Input leakage 1 μA max."       },       {         "number": "2",         "name": "V+",         "type": "power_in",-        "description": "Positive power supply, 1.8 V to 5.5 V. Absolute maximum 6.0 V referenced to GND. Quiescent supply current 1 \u03bcA max at V+=5.5 V."+        "description": "Positive power supply, 1.8 V to 5.5 V. Absolute maximum 6.0 V referenced to GND. Quiescent supply current 1 μA max at V+=5.5 V."       },       {         "number": "3",@@ -50,19 +50,19 @@         "number": "4",         "name": "NC",         "type": "bidirectional",-        "description": "Normally-Closed analog switch terminal. Connected to COM when IN = 0. Analog signal range 0 V to V+. RON \u2248 2.4 \u03a9 typ @ V+=5 V; continuous current \u00b1300 mA (peak \u00b1500 mA). May act as switch input or output."+        "description": "Normally-Closed analog switch terminal. Connected to COM when IN = 0. Analog signal range 0 V to V+. RON ≈ 2.4 Ω typ @ V+=5 V; continuous current ±300 mA (peak ±500 mA). May act as switch input or output."       },       {         "number": "5",         "name": "COM",         "type": "bidirectional",-        "description": "Common analog switch terminal (SPDT pole). Routes to NO when IN=1 and to NC when IN=0. Analog signal range 0 V to V+; \u00b1300 mA continuous."+        "description": "Common analog switch terminal (SPDT pole). Routes to NO when IN=1 and to NC when IN=0. Analog signal range 0 V to V+; ±300 mA continuous."       },       {         "number": "6",         "name": "NO",         "type": "bidirectional",-        "description": "Normally-Open analog switch terminal. Connected to COM when IN = 1. Analog signal range 0 V to V+. RON \u2248 2.4 \u03a9 typ @ V+=5 V; continuous current \u00b1300 mA (peak \u00b1500 mA). May act as switch input or output."+        "description": "Normally-Open analog switch terminal. Connected to COM when IN = 1. Analog signal range 0 V to V+. RON ≈ 2.4 Ω typ @ V+=5 V; continuous current ±300 mA (peak ±500 mA). May act as switch input or output."       }     ],     "provenance": {@@ -132,5 +132,8 @@     "docs/rs2101xc6-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file