← Commit history

ref3225aidbvr: specified limits as data (metadata.characteristics, 24 rows from the datasheet)

Ray ·c97920a39b · ·parent cd5f3d5
2 files changed +326
README.md+31
@@ -31,6 +31,37 @@ Same part, different packaging or reel option. - `REF3225AIDBVR` - `REF3225AIDBVT` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Output voltage | VOUT | 2.495 | 2.5 | 2.505 | V | TA = +25°C, ILOAD = 0mA, VIN = 5V | 3 |+| Initial accuracy |  | -0.2 | 0.01 | 0.2 | % | TA = +25°C, ILOAD = 0mA, VIN = 5V | 3 |+| Output voltage temperature drift, 0°C to +125°C | dVOUT/dT |  | 4 | 7 | ppm/°C | 0°C ≤ TA ≤ +125°C | 4 |+| Output voltage temperature drift, -40°C to +125°C | dVOUT/dT |  | 10.5 | 20 | ppm/°C | –40°C ≤ TA ≤ +125°C | 4 |+| Line regulation |  | -65 | 15 | 65 | ppm/V | VOUT + 0.05 ≤ VIN ≤ 5.5V | 4 |+| Load regulation, sourcing | dVOUT/dILOAD | -40 | 3 | 40 | µV/mA | 0mA < ILOAD < 10mA, VIN = VOUT + 250mV | 4 |+| Load regulation, sinking | dVOUT/dILOAD | -60 | 20 | 60 | µV/mA | –10mA < ILOAD < 0mA, VIN = VOUT + 100mV | 4 |+| Dropout voltage | VIN – VOUT |  | 5 | 50 | mV | 0°C ≤ TA ≤ +125°C | 4 |+| Output current | ILOAD | -10 |  | 10 | mA | VIN = VOUT + 250mV | 4 |+| Enable input low (reference in shutdown) | VL | 0 |  | 0.7 | V | Reference in Shutdown mode | 4 |+| Enable input high (reference active) | VH | 1.5 |  |  | V | Reference is active | 4 |+| Supply current (quiescent) | IQ |  | 100 | 120 | µA | IL = 0, ENABLE > 1.5V | 4 |+| Supply current (quiescent), over temperature | IQ |  | 115 | 135 | µA | 0°C ≤ TA ≤ +125°C | 4 |+| Shutdown supply current | IS |  | 0.1 | 1 | µA | ENABLE < 0.7V | 4 |+| Supply voltage | VIN |  |  | 5.5 | V | IL = 0 | 4 |+| Specified temperature range |  | -40 |  | 125 | °C |  | 4 |+| Input voltage |  |  |  | 7.5 | V |  | 2 |+| Operating temperature |  | -55 |  | 135 | °C | Over operating free-air temperature range | 2 |+| Storage temperature |  | -65 |  | 150 | °C |  | 2 |+| Junction temperature |  |  |  | 150 | °C |  | 2 |+| ESD human body model (HBM) |  |  |  | 4 | kV |  | 2 |+| ESD charged device model (CDM) |  |  |  | 1 | kV |  | 2 |+| ESD machine model (MM) |  |  |  | 400 | V |  | 2 |+| Thermal resistance, junction-to-ambient, SOT23-6 | θJA |  | 200 |  | °C/W |  | 4 |+ ## CAD (KiCad official)  - Symbol: `REF3225AIDBVR`
page.json+295
@@ -148,6 +148,301 @@       "Package": "SOT-23-6",       "Category": "PMIC",       "Pins": "6"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "691719783e90148d",+      "rows": [+        {+          "name": "Output voltage",+          "symbol": "VOUT",+          "kind": "electrical",+          "unit": "V",+          "min": 2.495,+          "typ": 2.5,+          "max": 2.505,+          "conditions": "TA = +25°C, ILOAD = 0mA, VIN = 5V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Initial accuracy",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -0.2,+          "typ": 0.01,+          "max": 0.2,+          "conditions": "TA = +25°C, ILOAD = 0mA, VIN = 5V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output voltage temperature drift, 0°C to +125°C",+          "symbol": "dVOUT/dT",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 4,+          "max": 7,+          "conditions": "0°C ≤ TA ≤ +125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output voltage temperature drift, -40°C to +125°C",+          "symbol": "dVOUT/dT",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 10.5,+          "max": 20,+          "conditions": "–40°C ≤ TA ≤ +125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Line regulation",+          "symbol": "",+          "kind": "electrical",+          "unit": "ppm/V",+          "min": -65,+          "typ": 15,+          "max": 65,+          "conditions": "VOUT + 0.05 ≤ VIN ≤ 5.5V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Load regulation, sourcing",+          "symbol": "dVOUT/dILOAD",+          "kind": "electrical",+          "unit": "µV/mA",+          "min": -40,+          "typ": 3,+          "max": 40,+          "conditions": "0mA < ILOAD < 10mA, VIN = VOUT + 250mV",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Load regulation, sinking",+          "symbol": "dVOUT/dILOAD",+          "kind": "electrical",+          "unit": "µV/mA",+          "min": -60,+          "typ": 20,+          "max": 60,+          "conditions": "–10mA < ILOAD < 0mA, VIN = VOUT + 100mV",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Dropout voltage",+          "symbol": "VIN – VOUT",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": 5,+          "max": 50,+          "conditions": "0°C ≤ TA ≤ +125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output current",+          "symbol": "ILOAD",+          "kind": "electrical",+          "unit": "mA",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "VIN = VOUT + 250mV",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Enable input low (reference in shutdown)",+          "symbol": "VL",+          "kind": "electrical",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 0.7,+          "conditions": "Reference in Shutdown mode",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Enable input high (reference active)",+          "symbol": "VH",+          "kind": "electrical",+          "unit": "V",+          "min": 1.5,+          "typ": null,+          "max": null,+          "conditions": "Reference is active",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply current (quiescent)",+          "symbol": "IQ",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 100,+          "max": 120,+          "conditions": "IL = 0, ENABLE > 1.5V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply current (quiescent), over temperature",+          "symbol": "IQ",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 115,+          "max": 135,+          "conditions": "0°C ≤ TA ≤ +125°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Shutdown supply current",+          "symbol": "IS",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 0.1,+          "max": 1,+          "conditions": "ENABLE < 0.7V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage",+          "symbol": "VIN",+          "kind": "recommended_operating",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 5.5,+          "conditions": "IL = 0",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Specified temperature range",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input voltage",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 7.5,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 135,+          "conditions": "Over operating free-air temperature range",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Junction temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "ESD human body model (HBM)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "kV",+          "min": null,+          "typ": null,+          "max": 4,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "ESD charged device model (CDM)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "kV",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "ESD machine model (MM)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 400,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance, junction-to-ambient, SOT23-6",+          "symbol": "θJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 200,+          "max": null,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        }+      ]     }   },   "sections": [