← Commit history
ref102bu: specified limits as data (metadata.characteristics, 15 rows from the datasheet)
2 files changed
+210−1
README.md+22@@ -26,6 +26,28 @@ REF102BU from Texas Instruments, in a SOIC-8. Pinout and pin descriptions extrac | Category | Power Management (PMIC) | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Initial output voltage (TA = 25°C), REF102B | VOUT | 9.995 | | 10.005 | V | TA = 25°C | 3 |+| Output voltage drift vs temperature, REF102B (box method) | | | | 5 | ppm/°C | | 3 |+| Line regulation vs supply, REF102B | | | | 1 | ppm/V | VS = 11.4V to 36V | 3 |+| Load regulation vs output current, REF102B (sourcing) | | | | 10 | ppm/mA | IL = 0mA to +10mA | 3 |+| Load regulation vs output current, REF102B (sinking) | | | | 20 | ppm/mA | IL = 0mA to –5mA | 3 |+| Long-term stability vs time, P and U packages, REF102B | | | | 20 | ppm/1000hr | TA = +25°C; P, U Packages | 3 |+| Trim range | | -3 | | 3 | % | | 3 |+| Capacitive load, max | CL | | | 1000 | pF | | 3 |+| Output current | IOUT | -5 | | 10 | mA | | 3 |+| Input voltage range | VS | 11.4 | | 36 | V | | 3 |+| Quiescent current | IQ | | | 1.4 | mA | IOUT = 0 | 3 |+| Specified temperature range, REF102A/B/C | TA | -25 | | 85 | °C | | 3 |+| Input voltage (absolute maximum) | VIN | | | 40 | V | | 2 |+| Operating temperature, P and U packages (absolute maximum rating) | TA | -25 | | 85 | °C | P, U packages | 2 |+| Storage temperature range, P and U packages | TSTG | -40 | | 125 | °C | P, U packages | 2 |+ ## CAD (KiCad official) - Symbol: `REF102BU`
page.json+188−1@@ -179,6 +179,193 @@ "Package": "SOIC-8", "Category": "Power Management (PMIC)", "Pins": "8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "5860560fea70aa71",+ "rows": [+ {+ "name": "Initial output voltage (TA = 25°C), REF102B",+ "symbol": "VOUT",+ "kind": "tolerance",+ "unit": "V",+ "min": 9.995,+ "typ": null,+ "max": 10.005,+ "conditions": "TA = 25°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Output voltage drift vs temperature, REF102B (box method)",+ "symbol": "",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": null,+ "typ": null,+ "max": 5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Line regulation vs supply, REF102B",+ "symbol": "",+ "kind": "electrical",+ "unit": "ppm/V",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "VS = 11.4V to 36V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Load regulation vs output current, REF102B (sourcing)",+ "symbol": "",+ "kind": "electrical",+ "unit": "ppm/mA",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "IL = 0mA to +10mA",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Load regulation vs output current, REF102B (sinking)",+ "symbol": "",+ "kind": "electrical",+ "unit": "ppm/mA",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "IL = 0mA to –5mA",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Long-term stability vs time, P and U packages, REF102B",+ "symbol": "",+ "kind": "electrical",+ "unit": "ppm/1000hr",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "TA = +25°C; P, U Packages",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Trim range",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -3,+ "typ": null,+ "max": 3,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Capacitive load, max",+ "symbol": "CL",+ "kind": "electrical",+ "unit": "pF",+ "min": null,+ "typ": null,+ "max": 1000,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Output current",+ "symbol": "IOUT",+ "kind": "electrical",+ "unit": "mA",+ "min": -5,+ "typ": null,+ "max": 10,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range",+ "symbol": "VS",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 11.4,+ "typ": null,+ "max": 36,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current",+ "symbol": "IQ",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1.4,+ "conditions": "IOUT = 0",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Specified temperature range, REF102A/B/C",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -25,+ "typ": null,+ "max": 85,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Input voltage (absolute maximum)",+ "symbol": "VIN",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating temperature, P and U packages (absolute maximum rating)",+ "symbol": "TA",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -25,+ "typ": null,+ "max": 85,+ "conditions": "P, U packages",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range, P and U packages",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "P, U packages",+ "source_page": 2,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -220,4 +407,4 @@ "visibility": { "public": true }-}+}