← Commit history

ref102bu: specified limits as data (metadata.characteristics, 15 rows from the datasheet)

Ray ·1c7e05820d · ·parent 5c53989
2 files changed +210−1
README.md+22
@@ -26,6 +26,28 @@ REF102BU from Texas Instruments, in a SOIC-8. Pinout and pin descriptions extrac | Category | Power Management (PMIC) | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Initial output voltage (TA = 25°C), REF102B | VOUT | 9.995 |  | 10.005 | V | TA = 25°C | 3 |+| Output voltage drift vs temperature, REF102B (box method) |  |  |  | 5 | ppm/°C |  | 3 |+| Line regulation vs supply, REF102B |  |  |  | 1 | ppm/V | VS = 11.4V to 36V | 3 |+| Load regulation vs output current, REF102B (sourcing) |  |  |  | 10 | ppm/mA | IL = 0mA to +10mA | 3 |+| Load regulation vs output current, REF102B (sinking) |  |  |  | 20 | ppm/mA | IL = 0mA to –5mA | 3 |+| Long-term stability vs time, P and U packages, REF102B |  |  |  | 20 | ppm/1000hr | TA = +25°C; P, U Packages | 3 |+| Trim range |  | -3 |  | 3 | % |  | 3 |+| Capacitive load, max | CL |  |  | 1000 | pF |  | 3 |+| Output current | IOUT | -5 |  | 10 | mA |  | 3 |+| Input voltage range | VS | 11.4 |  | 36 | V |  | 3 |+| Quiescent current | IQ |  |  | 1.4 | mA | IOUT = 0 | 3 |+| Specified temperature range, REF102A/B/C | TA | -25 |  | 85 | °C |  | 3 |+| Input voltage (absolute maximum) | VIN |  |  | 40 | V |  | 2 |+| Operating temperature, P and U packages (absolute maximum rating) | TA | -25 |  | 85 | °C | P, U packages | 2 |+| Storage temperature range, P and U packages | TSTG | -40 |  | 125 | °C | P, U packages | 2 |+ ## CAD (KiCad official)  - Symbol: `REF102BU`
page.json+188−1
@@ -179,6 +179,193 @@       "Package": "SOIC-8",       "Category": "Power Management (PMIC)",       "Pins": "8"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "5860560fea70aa71",+      "rows": [+        {+          "name": "Initial output voltage (TA = 25°C), REF102B",+          "symbol": "VOUT",+          "kind": "tolerance",+          "unit": "V",+          "min": 9.995,+          "typ": null,+          "max": 10.005,+          "conditions": "TA = 25°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output voltage drift vs temperature, REF102B (box method)",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Line regulation vs supply, REF102B",+          "symbol": "",+          "kind": "electrical",+          "unit": "ppm/V",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VS = 11.4V to 36V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Load regulation vs output current, REF102B (sourcing)",+          "symbol": "",+          "kind": "electrical",+          "unit": "ppm/mA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "IL = 0mA to +10mA",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Load regulation vs output current, REF102B (sinking)",+          "symbol": "",+          "kind": "electrical",+          "unit": "ppm/mA",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "IL = 0mA to –5mA",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Long-term stability vs time, P and U packages, REF102B",+          "symbol": "",+          "kind": "electrical",+          "unit": "ppm/1000hr",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "TA = +25°C; P, U Packages",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Trim range",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -3,+          "typ": null,+          "max": 3,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Capacitive load, max",+          "symbol": "CL",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": null,+          "max": 1000,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output current",+          "symbol": "IOUT",+          "kind": "electrical",+          "unit": "mA",+          "min": -5,+          "typ": null,+          "max": 10,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range",+          "symbol": "VS",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 11.4,+          "typ": null,+          "max": 36,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Quiescent current",+          "symbol": "IQ",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 1.4,+          "conditions": "IOUT = 0",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Specified temperature range, REF102A/B/C",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -25,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input voltage (absolute maximum)",+          "symbol": "VIN",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature, P and U packages (absolute maximum rating)",+          "symbol": "TA",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -25,+          "typ": null,+          "max": 85,+          "conditions": "P, U packages",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range, P and U packages",+          "symbol": "TSTG",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "P, U packages",+          "source_page": 2,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -220,4 +407,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}