← Commit history

opa552faktwt: specified limits as data (metadata.characteristics, 32 rows from the datasheet)

Ray ·35f6a79c15 · ·parent 119d1cd
2 files changed +431−1
README.md+39
@@ -26,6 +26,45 @@ OPA552FAKTWT from Texas Instruments, in a TO-263-7. Pinout and pin descriptions | Category | Amplifiers/Comparators | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Supply voltage VS = (V+) to (V–) | VS |  |  | 60 | V |  | 4 |+| Operating temperature | TA | -55 |  | 125 | °C |  | 4 |+| Junction temperature | TJ |  |  | 150 | °C |  | 4 |+| Storage temperature | Tstg | -65 |  | 150 | °C |  | 4 |+| Supply voltage | VS | 8 |  | 60 | V | printed as (±4) and (±30) V | 4 |+| Specified temperature |  | -40 |  | 125 | °C |  | 4 |+| Junction-to-ambient thermal resistance (KTW, DDPAK/TO-263-7) | RθJA |  | 22.7 |  | °C/W | Thermal Information table, KTW column | 4 |+| Junction-to-case (top) thermal resistance (KTW) | RθJC(top) |  | 34.7 |  | °C/W | Thermal Information table, KTW column | 4 |+| Junction-to-board thermal resistance (KTW) | RθJB |  | 7.7 |  | °C/W | Thermal Information table, KTW column | 4 |+| Junction-to-top characterization parameter (KTW) | ψJT |  | 3.3 |  | °C/W | Thermal Information table, KTW column | 4 |+| Junction-to-board characterization parameter (KTW) | ψJB |  | 7.7 |  | °C/W | Thermal Information table, KTW column | 4 |+| Junction-to-case (bottom) thermal resistance (KTW) | RθJC(bot) |  | 0.6 |  | °C/W | Thermal Information table, KTW column | 4 |+| Junction-to-ambient thermal resistance (DDPAK/TO-263 text value) | θJA |  | 65 |  | °C/W | no heat sinking | 18 |+| Input offset voltage | VOS | -3 | 1 | 3 | mV | VCM = 0 V, IO = 0 mA | 5 |+| Input offset voltage over temperature | VOS | -5 |  | 5 | mV | TJ = –40°C to 125°C | 5 |+| Input offset voltage vs temperature | dVOS/dT | -7 |  | 7 | µV/°C | TJ = –40°C to 125°C | 5 |+| Input offset voltage vs power supply | PSRR |  | 10 | 30 | µV/V | VS = ±4 V to ±30 V, VCM = 0 V | 5 |+| Input bias current | IB | -100 | 20 | 100 | pA |  | 5 |+| Input offset current | IOS | -100 | 3 | 100 | pA |  | 5 |+| Common-mode rejection ratio | CMRR | 92 | 102 |  | dB | –27.5 V < VCM < +27.5 V | 5 |+| Open-loop voltage gain | AOL | 110 | 126 |  | dB | RL = 3 kΩ, –28 V < VO < +28 V | 5 |+| Open-loop voltage gain over temperature | AOL | 100 |  |  | dB | RL = 3 kΩ, –28 V < VO < +28 V, TJ = –40°C to 125°C | 5 |+| Slew rate (OPA552) | SR | -24 |  | 24 | V/µs | G = 5 | 5 |+| Maximum continuous output current | IO | -200 |  | 200 | mA | DC | 6 |+| Short-circuit current | ISC | -380 |  | 380 | mA |  | 6 |+| Shutdown flag source current, normal operation |  |  | 0.05 | 1 | µA | Normal operation, sourcing | 6 |+| Shutdown flag source current, thermal shutdown |  | 80 | 120 | 160 | µA | Thermal shutdown, sourcing | 6 |+| Operating voltage range |  | 4 |  | 30 | V |  | 6 |+| Quiescent current | IQ |  | 7 | 8.5 | mA | IO = 0 mA | 6 |+| Quiescent current over temperature | IQ |  |  | 10 | mA | TJ = –40°C to 125°C | 6 |+| Specified temperature range | TJ | -40 |  | 125 | °C | Specified range | 6 |+| Operating temperature range | TJ | -55 |  | 125 | °C | Operating range | 6 |+ ## CAD (KiCad official)  - Symbol: `OPA552FAKTWT`
page.json+392−1
@@ -181,6 +181,397 @@       "Package": "TO-263-7",       "Category": "Amplifiers/Comparators",       "Pins": "8"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "cc8f7dbd702fda59",+      "rows": [+        {+          "name": "Supply voltage VS = (V+) to (V–)",+          "symbol": "VS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature",+          "symbol": "TA",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage",+          "symbol": "VS",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 8,+          "typ": null,+          "max": 60,+          "conditions": "printed as (±4) and (±30) V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Specified temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-ambient thermal resistance (KTW, DDPAK/TO-263-7)",+          "symbol": "RθJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 22.7,+          "max": null,+          "conditions": "Thermal Information table, KTW column",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (top) thermal resistance (KTW)",+          "symbol": "RθJC(top)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 34.7,+          "max": null,+          "conditions": "Thermal Information table, KTW column",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-board thermal resistance (KTW)",+          "symbol": "RθJB",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 7.7,+          "max": null,+          "conditions": "Thermal Information table, KTW column",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-top characterization parameter (KTW)",+          "symbol": "ψJT",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 3.3,+          "max": null,+          "conditions": "Thermal Information table, KTW column",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-board characterization parameter (KTW)",+          "symbol": "ψJB",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 7.7,+          "max": null,+          "conditions": "Thermal Information table, KTW column",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (bottom) thermal resistance (KTW)",+          "symbol": "RθJC(bot)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 0.6,+          "max": null,+          "conditions": "Thermal Information table, KTW column",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-ambient thermal resistance (DDPAK/TO-263 text value)",+          "symbol": "θJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 65,+          "max": null,+          "conditions": "no heat sinking",+          "source_page": 18,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage",+          "symbol": "VOS",+          "kind": "electrical",+          "unit": "mV",+          "min": -3,+          "typ": 1,+          "max": 3,+          "conditions": "VCM = 0 V, IO = 0 mA",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage over temperature",+          "symbol": "VOS",+          "kind": "electrical",+          "unit": "mV",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "TJ = –40°C to 125°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage vs temperature",+          "symbol": "dVOS/dT",+          "kind": "electrical",+          "unit": "µV/°C",+          "min": -7,+          "typ": null,+          "max": 7,+          "conditions": "TJ = –40°C to 125°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input offset voltage vs power supply",+          "symbol": "PSRR",+          "kind": "electrical",+          "unit": "µV/V",+          "min": null,+          "typ": 10,+          "max": 30,+          "conditions": "VS = ±4 V to ±30 V, VCM = 0 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input bias current",+          "symbol": "IB",+          "kind": "electrical",+          "unit": "pA",+          "min": -100,+          "typ": 20,+          "max": 100,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input offset current",+          "symbol": "IOS",+          "kind": "electrical",+          "unit": "pA",+          "min": -100,+          "typ": 3,+          "max": 100,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection ratio",+          "symbol": "CMRR",+          "kind": "electrical",+          "unit": "dB",+          "min": 92,+          "typ": 102,+          "max": null,+          "conditions": "–27.5 V < VCM < +27.5 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Open-loop voltage gain",+          "symbol": "AOL",+          "kind": "electrical",+          "unit": "dB",+          "min": 110,+          "typ": 126,+          "max": null,+          "conditions": "RL = 3 kΩ, –28 V < VO < +28 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Open-loop voltage gain over temperature",+          "symbol": "AOL",+          "kind": "electrical",+          "unit": "dB",+          "min": 100,+          "typ": null,+          "max": null,+          "conditions": "RL = 3 kΩ, –28 V < VO < +28 V, TJ = –40°C to 125°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Slew rate (OPA552)",+          "symbol": "SR",+          "kind": "electrical",+          "unit": "V/µs",+          "min": -24,+          "typ": null,+          "max": 24,+          "conditions": "G = 5",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Maximum continuous output current",+          "symbol": "IO",+          "kind": "electrical",+          "unit": "mA",+          "min": -200,+          "typ": null,+          "max": 200,+          "conditions": "DC",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Short-circuit current",+          "symbol": "ISC",+          "kind": "electrical",+          "unit": "mA",+          "min": -380,+          "typ": null,+          "max": 380,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Shutdown flag source current, normal operation",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 0.05,+          "max": 1,+          "conditions": "Normal operation, sourcing",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Shutdown flag source current, thermal shutdown",+          "symbol": "",+          "kind": "electrical",+          "unit": "µA",+          "min": 80,+          "typ": 120,+          "max": 160,+          "conditions": "Thermal shutdown, sourcing",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Operating voltage range",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": 4,+          "typ": null,+          "max": 30,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Quiescent current",+          "symbol": "IQ",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 7,+          "max": 8.5,+          "conditions": "IO = 0 mA",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Quiescent current over temperature",+          "symbol": "IQ",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "TJ = –40°C to 125°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Specified temperature range",+          "symbol": "TJ",+          "kind": "electrical",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "Specified range",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature range",+          "symbol": "TJ",+          "kind": "electrical",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 125,+          "conditions": "Operating range",+          "source_page": 6,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -222,4 +613,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}