← Commit history
page.json+11−8@@ -54,7 +54,7 @@ }, { "number": "2",- "name": "VIN\u2013",+ "name": "VIN–", "type": "power_in", "description": "Inverting input with common-mode voltage range from (V-) - 0.1 V to (V+) - 2.3 V" },@@ -62,31 +62,31 @@ "number": "3", "name": "ILIM", "type": "input",- "description": "Current limit control input; connect resistor RCL between ILIM and V- to set output current limit from 0 A to 5 A per ILIM = (15000)(4.75) / (13750 \u03a9 + RCL)"+ "description": "Current limit control input; connect resistor RCL between ILIM and V- to set output current limit from 0 A to 5 A per ILIM = (15000)(4.75) / (13750 Ω + RCL)" }, { "number": "4",- "name": "V\u2013",+ "name": "V–", "type": "power_in",- "description": "Negative power supply; supports supply voltage of 8 V to 60 V (single supply) or \u00b14 V to \u00b130 V (dual supply)"+ "description": "Negative power supply; supports supply voltage of 8 V to 60 V (single supply) or ±4 V to ±30 V (dual supply)" }, { "number": "5", "name": "V+", "type": "power_in",- "description": "Positive power supply; supports supply voltage of 8 V to 60 V (single supply) or \u00b14 V to \u00b130 V (dual supply)"+ "description": "Positive power supply; supports supply voltage of 8 V to 60 V (single supply) or ±4 V to ±30 V (dual supply)" }, { "number": "6", "name": "VO", "type": "output",- "description": "Amplifier output with maximum continuous current of \u00b13 A DC and 3 Arms AC; output voltage swing limited by supply voltage and load impedance"+ "description": "Amplifier output with maximum continuous current of ±3 A DC and 3 Arms AC; output voltage swing limited by supply voltage and load impedance" }, { "number": "7", "name": "E/S", "type": "bidirectional",- "description": "Enable/disable control and thermal shutdown status output; pull to \u2264 (V-) + 0.8 V to disable output (1 \u00b5s disable time) or \u2265 (V-) + 2.4 V to enable output (3 \u00b5s enable time); thermal shutdown engages at 160\u00b0C and resets at 140\u00b0C"+ "description": "Enable/disable control and thermal shutdown status output; pull to ≤ (V-) + 0.8 V to disable output (1 µs disable time) or ≥ (V-) + 2.4 V to enable output (3 µs enable time); thermal shutdown engages at 160°C and resets at 140°C" }, { "number": "8",@@ -172,5 +172,8 @@ "docs/opa548f-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }