component
OPA4347UA
Public Made by Adomby adom
UMW Operational Amplifier, SOP-14. Pinout extracted from the datasheet, KiCad symbol/footprint/3D.
← Commit history
page.json+8−5@@ -32,13 +32,13 @@ "number": "1", "name": "OUTA", "type": "output",- "description": "Amplifier A output. Rail-to-rail; swings within ~5 mV of V+/V- into 100 k\u03a9. Short-circuit current \u00b117 mA (typ)."+ "description": "Amplifier A output. Rail-to-rail; swings within ~5 mV of V+/V- into 100 kΩ. Short-circuit current ±17 mA (typ)." }, { "number": "2", "name": "-INA", "type": "input",- "description": "Amplifier A inverting input. Rail-to-rail input, extends 200 mV beyond supplies. Bias current \u00b10.5 pA (typ)."+ "description": "Amplifier A inverting input. Rail-to-rail input, extends 200 mV beyond supplies. Bias current ±0.5 pA (typ)." }, { "number": "3",@@ -50,7 +50,7 @@ "number": "4", "name": "V+", "type": "power_in",- "description": "Positive supply. Single-supply range 2.3 V to 5.5 V (specified 2.5-5.5 V). Total V+ \u2212 V\u2212 must not exceed 7.5 V."+ "description": "Positive supply. Single-supply range 2.3 V to 5.5 V (specified 2.5-5.5 V). Total V+ − V− must not exceed 7.5 V." }, { "number": "5",@@ -92,7 +92,7 @@ "number": "11", "name": "V-", "type": "power_in",- "description": "Negative supply / ground for single-supply operation. Absolute maximum V+ \u2212 V\u2212 = 7.5 V."+ "description": "Negative supply / ground for single-supply operation. Absolute maximum V+ − V− = 7.5 V." }, { "number": "12",@@ -174,5 +174,8 @@ "docs/opa4347ua-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }