← Commit history

Set visibility: public

Ray ·734dbd678d ·1mo ago ·parent 93e0c55
1 file changed +11−8
page.json+11−8
@@ -32,31 +32,31 @@         "number": "1",         "name": "OUTA",         "type": "output",-        "description": "Op-amp A output. Drives loads down to 600\u03a9 at \u00b110Vrms typ. Short-circuit output current ~38mA typ."+        "description": "Op-amp A output. Drives loads down to 600Ω at ±10Vrms typ. Short-circuit output current ~38mA typ."       },       {         "number": "2",         "name": "INA-",         "type": "input",-        "description": "Op-amp A inverting input. Bipolar input, input bias current ~200nA typ, input resistance ~300k\u03a9 typ."+        "description": "Op-amp A inverting input. Bipolar input, input bias current ~200nA typ, input resistance ~300kΩ typ."       },       {         "number": "3",         "name": "INA+",         "type": "input",-        "description": "Op-amp A non-inverting input. Common-mode input voltage range \u00b112V min at \u00b115V supply. When used in voltage-follower configuration, add a series current-limit resistor (e.g. 1k\u03a9) to protect internal input protection diodes at power-up."+        "description": "Op-amp A non-inverting input. Common-mode input voltage range ±12V min at ±15V supply. When used in voltage-follower configuration, add a series current-limit resistor (e.g. 1kΩ) to protect internal input protection diodes at power-up."       },       {         "number": "4",         "name": "V-",         "type": "power_in",-        "description": "Negative supply rail. Operating range -3V to -22V referenced to ground for split supply operation (\u00b13V to \u00b122V total)."+        "description": "Negative supply rail. Operating range -3V to -22V referenced to ground for split supply operation (±3V to ±22V total)."       },       {         "number": "5",         "name": "INB+",         "type": "input",-        "description": "Op-amp B non-inverting input. Common-mode input voltage range \u00b112V min at \u00b115V supply. Same input-protection guidance as INA+."+        "description": "Op-amp B non-inverting input. Common-mode input voltage range ±12V min at ±15V supply. Same input-protection guidance as INA+."       },       {         "number": "6",@@ -68,13 +68,13 @@         "number": "7",         "name": "OUTB",         "type": "output",-        "description": "Op-amp B output. Drives loads down to 600\u03a9 at \u00b110Vrms typ."+        "description": "Op-amp B output. Drives loads down to 600Ω at ±10Vrms typ."       },       {         "number": "8",         "name": "V+",         "type": "power_in",-        "description": "Positive supply rail. Operating range +3V to +22V referenced to ground for split supply operation. Total supply current ~9mA typ (both amps, RL=\u221e)."+        "description": "Positive supply rail. Operating range +3V to +22V referenced to ground for split supply operation. Total supply current ~9mA typ (both amps, RL=∞)."       }     ],     "provenance": {@@ -138,5 +138,8 @@     "docs/njm5532m-te1-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file