← Commit history

ncp1380ddr2g: restore the component block (pinout + model declarations) from this page's own README and symbol

Ray ·2bf711817e · ·parent 9c4b88e
1 file changed +75−1
page.json+75−1
@@ -33,5 +33,79 @@   "author": {     "name": "Ray",     "email": "[email protected]"+  },+  "component": {+    "mpn": "NCP1380DDR2G",+    "manufacturer": "onsemi",+    "package": "SOIC-8",+    "pin_count": 8,+    "category": "AC-DC Controllers and Regulators",+    "datasheet": "https://www.onsemi.com/pdf/datasheet/ncp1380d-d.pdf",+    "parts": {+      "symbol": "ncp1380ddr2g.kicad_sym",+      "footprint": "ncp1380ddr2g.kicad_mod",+      "model_3d": "ncp1380ddr2g-etched.glb",+      "model_3d_plain": "ncp1380ddr2g.glb",+      "model_3d_step": "ncp1380ddr2g-etched.step",+      "model_3d_step_plain": "ncp1380ddr2g.step",+      "lbr": "ncp1380ddr2g.lbr"+    },+    "pins": [+      {+        "number": "1",+        "name": "ZCD",+        "type": "input",+        "description": "Zero Crossing Detection input - connected to the transformer auxiliary winding to detect core-reset events (55 mV typ. falling threshold, 35 mV hysteresis). Also serves as the Over Power Protection (OPP) input: a negative voltage down to -300 mV applied during on-time reduces the internal peak-current setpoint by up to 37.5%. Internally clamped (-0.7 V low / +10 V high), ±3/-2 mA max."+      },+      {+        "number": "2",+        "name": "FB",+        "type": "input",+        "description": "Feedback input from optocoupler collector for output regulation. Internally pulled up (~18 kΩ) to VDD. FB voltage sets the operating valley (1st→4th) and enters VCO frequency-foldback mode below 0.8 V (falling)/1.4 V (rising). Peak-current setpoint = VFB/4."+      },+      {+        "number": "3",+        "name": "CS",+        "type": "input",+        "description": "Current Sense input monitoring the primary MOSFET peak current via an external sense resistor. Cycle-by-cycle current limit at VILIM = 0.8 V (with 275 ns leading-edge blanking). A second faster comparator at VCS(stop) = 1.2 V (120 ns LEB) provides immediate winding-short protection."+      },+      {+        "number": "4",+        "name": "GND",+        "type": "power_in",+        "description": "Controller ground reference for all internal circuitry and the gate driver return."+      },+      {+        "number": "5",+        "name": "DRV",+        "type": "output",+        "description": "Gate-driver output to the external primary MOSFET. +500 mA source / -800 mA sink peak capability (RSRC ≈ 20 Ω, RSNK ≈ 12.5 Ω). Output high clamped to ~13 V typ (10.5-15.5 V), rise/fall ≈ 40/25 ns into 1 nF. Absolute max 20 V, ±1000 mA."+      },+      {+        "number": "6",+        "name": "VCC",+        "type": "power_in",+        "description": "Controller supply, fed from an auxiliary winding. VCC(on) = 17 V typ startup, VCC(off) = 9 V typ UVLO, operating up to 28 V max. Startup current ~10 µA; ICC ≈ 2.65 mA switching at 65 kHz with 1 nF DRV load. Clamped to VCC(latch) ≈ 7.2 V when latched off."+      },+      {+        "number": "7",+        "name": "Fault",+        "type": "bidirectional",+        "description": "Combined protection pin. On the D variant (this part): Brown-Out / OVP - a resistor divider from the HV bulk rail is sensed against VBO = 0.8 V (falling) with a 10 µA hysteresis source; a zener-diode injection above VOVP = 2.5 V latches the controller off. Internal clamp Rclamp ≈ 1.55 kΩ / Vclamp ≈ 1.2 V limits pin voltage; open-pin clamp 1.0-1.4 V."+      },+      {+        "number": "8",+        "name": "CT",+        "type": "passive",+        "description": "Timing-capacitor pin for VCO/frequency-foldback mode. An external capacitor (≈220 pF recommended) is charged by a 20 µA source and compared to an FB-derived threshold; when it reaches the threshold the cap is discharged and a new switching period starts. VCT(MAX) ≈ 5.4 V."+      }+    ],+    "provenance": {+      "rebuilt": "component block rebuilt 2026-10-05 from this page's own README pinout table and .kicad_sym (pins cross-checked), no re-extraction"+    },+    "viewers": {+      "symbol": "viewers/symbol.html",+      "footprint": "viewers/footprint.html"+    }   }-}\ No newline at end of file+}