← Commit history
page.json+8−5@@ -38,7 +38,7 @@ "number": "1", "name": "OUT2", "type": "output",- "description": "Motor reverse drive output; on-resistance 0.5\u03a9 (\u00b1100mA) or 0.7\u03a9 (\u00b1500mA) at VDD=6.5V; conducts to VDD when IN2=H and IN1=L."+ "description": "Motor reverse drive output; on-resistance 0.5Ω (±100mA) or 0.7Ω (±500mA) at VDD=6.5V; conducts to VDD when IN2=H and IN1=L." }, { "number": "2",@@ -50,13 +50,13 @@ "number": "3", "name": "IN2", "type": "input",- "description": "Motor reverse control signal input; 15 k\u03a9 internal pull-down resistor, logic high \u22652.4V, logic low \u22640.6V at VDD=3V, maximum input voltage 5.5V."+ "description": "Motor reverse control signal input; 15 kΩ internal pull-down resistor, logic high ≥2.4V, logic low ≤0.6V at VDD=3V, maximum input voltage 5.5V." }, { "number": "4", "name": "IN1", "type": "input",- "description": "Motor forward control signal input; 15 k\u03a9 internal pull-down resistor, logic high \u22652.4V, logic low \u22640.6V at VDD=3V, maximum input voltage 5.5V."+ "description": "Motor forward control signal input; 15 kΩ internal pull-down resistor, logic high ≥2.4V, logic low ≤0.6V at VDD=3V, maximum input voltage 5.5V." }, { "number": "5",@@ -68,7 +68,7 @@ "number": "6", "name": "OUT1", "type": "output",- "description": "Motor forward drive output; on-resistance 0.5\u03a9 (\u00b1100mA) or 0.7\u03a9 (\u00b1500mA) at VDD=6.5V; conducts to VDD when IN1=H and IN2=L."+ "description": "Motor forward drive output; on-resistance 0.5Ω (±100mA) or 0.7Ω (±500mA) at VDD=6.5V; conducts to VDD when IN1=H and IN2=L." } ], "provenance": {@@ -146,5 +146,8 @@ "docs/mx116h-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }