← Commit history

Set visibility: public

Ray ·8d6e41c6c3 ·1mo ago ·parent b9a656c
1 file changed +5−2
page.json+5−2
@@ -38,7 +38,7 @@         "number": "2",         "name": "Out",         "type": "output",-        "description": "Open-drain output (VOUT=Low when magnetic flux density B>Bop; VOUT=High/hi-Z when B<Brp). Requires external pull-up resistor (recommended 1kOhm-10kOhm). Max output voltage 65V; continuous output current 40mA; short-circuit protection ~50mA; VDSON \u22640.4V at IOUT=15mA."+        "description": "Open-drain output (VOUT=Low when magnetic flux density B>Bop; VOUT=High/hi-Z when B<Brp). Requires external pull-up resistor (recommended 1kOhm-10kOhm). Max output voltage 65V; continuous output current 40mA; short-circuit protection ~50mA; VDSON ≤0.4V at IOUT=15mA."       },       {         "number": "3",@@ -108,5 +108,8 @@     "docs/mt8362et-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file