component
MLX90614ESF-BCI-000-TU - 3 V Digital IR Thermometer, 5 deg FOV
Public Made by Adomby adom
Melexis MLX90614ESF-BCI-000-TU: factory-calibrated non-contact infrared thermometer, 3 V supply, 5 degree field of view (long collimator cap), gradient compensated, SMBus and PWM output, TO-39 4-lead can.
← Commit history
page.json+124−137@@ -1,143 +1,130 @@ {- "schema_version": 1,- "slug": "mlx90614esf-bci-000-tu",- "type": "component",- "kind": "component",- "title": "MLX90614ESF-BCI-000-TU - 3 V Digital IR Thermometer, 5 deg FOV",- "brief": "Melexis MLX90614ESF-BCI-000-TU: factory-calibrated non-contact infrared thermometer, 3 V supply, 5 degree field of view (long collimator cap), gradient compensated, SMBus and PWM output, TO-39 4-lead can.",- "version": "1.0.0",- "because": "No MLX90614 page exists on the wiki (adom-wiki discover search MLX90614 returned 0 results on 2026-10-21); this is the exact-MPN component record for MLX90614ESF-BCI-000-TU.",- "hero": {- "type": "billboard",- "headline": "MLX90614ESF-BCI-000-TU",- "subhead": "Melexis 3 V digital IR thermometer, 5 degree field of view, TO-39 can",- "screenshot": "docs/hero.png",- "chrome": false+ "slug": "mlx90614esf-bci-000-tu",+ "version": "1.0.0",+ "type": "hardware",+ "kind": "component",+ "org": "adom",+ "title": "MLX90614ESF-BCI-000-TU - 3 V Digital IR Thermometer, 5 deg FOV",+ "description": "Melexis MLX90614ESF-BCI-000-TU: factory-calibrated non-contact infrared thermometer, 3 V supply, 5 degree field of view (long collimator cap), gradient compensated, SMBus and PWM output, TO-39 4-lead can.",+ "license": "CC-BY-4.0",+ "tags": [+ "component",+ "sensor",+ "temperature-sensor",+ "infrared",+ "thermopile",+ "tht",+ "to-39"+ ],+ "component": {+ "mpn": "MLX90614ESF-BCI-000-TU",+ "manufacturer": "Melexis",+ "category": "Sensors",+ "subcategory": "Infrared (non-contact) temperature sensor",+ "package": "TO-39 4-lead can (MLX90614xCI 5 deg collimator cap, 20.2 mm tall)",+ "pin_count": 4,+ "datasheet": "https://www.melexis.com/-/media/files/documents/datasheets/mlx90614-datasheet-melexis.pdf",+ "wiki_url": "https://wiki.adom.inc/adom/mlx90614esf-bci-000-tu",+ "body_size": {+ "x_mm": 9.15,+ "y_mm": 9.15,+ "z_mm": 20.2,+ "pitch_mm": 2.54 },- "component": {- "mpn": "MLX90614ESF-BCI-000-TU",- "manufacturer": "Melexis",- "package": "TO-39 4-lead can (MLX90614xCI 5 deg collimator cap, 20.2 mm tall)",- "pin_count": 4,- "category": "Sensors",- "subcategory": "Infrared (non-contact) temperature sensor",- "body_size": {- "x_mm": 9.15,- "y_mm": 9.15,- "z_mm": 20.2,- "pitch_mm": 2.54- },- "parts": {- "symbol": "mlx90614esf-bci-000-tu.kicad_sym",- "footprint": "mlx90614esf-bci-000-tu.kicad_mod",- "model_3d": "mlx90614esf-bci-000-tu-hero.glb",- "model_3d_plain": "mlx90614esf-bci-000-tu-etched.glb",- "model_3d_step": "mlx90614esf-bci-000-tu-etched.step",- "model_3d_step_plain": "mlx90614esf-bci-000-tu.step",- "step": "mlx90614esf-bci-000-tu-etched.step",- "lbr": "mlx90614esf-bci-000-tu.lbr",- "datasheet": "docs/mlx90614esf-bci-000-tu-datasheet.pdf"- },- "distributor_links": {- "mouser": {- "part": "482-90614ESFBCI000TU",- "url": "https://www.mouser.com/en/ProductDetail/Melexis/MLX90614ESF-BCI-000-TU?qs=KuGPmAKtFKXB55OHcItFHA%3D%3D",- "stock": 859,- "checked": "2026-10-21"- },- "digikey": {- "part": "MLX90614ESF-BCI-000-TU-ND",- "url": "https://www.digikey.com/en/products/detail/melexis-technologies-nv/MLX90614ESF-BCI-000-TU/2666249",- "stock": 1426,- "checked": "2026-10-21"- },- "lcsc": false- },- "datasheet": "https://www.melexis.com/-/media/files/documents/datasheets/mlx90614-datasheet-melexis.pdf",- "wiki_url": "https://wiki.adom.inc/adom/mlx90614esf-bci-000-tu",- "viewers": {- "symbol": "viewers/symbol.html",- "footprint": "viewers/footprint.html"- },- "viewer_3d": {- "ground": false,- "animate": false,- "shadows": false,- "tooltips": "authored"- },- "models": "models.json",- "lod": "lod/manifest.json",- "verification": "verification.json",- "marking": {- "lines": [- "BCI"- ],- "source": "Melexis MLX90614 datasheet Rev 021 p.50 Table 20 (laser marking: 3-letter device code BCI followed by a 7-digit lot number)",- "surface": "side wall (+Y), position not given by the datasheet",- "colour": "dark laser mark on nickel can",- "note": "lot digits omitted: they differ per lot"- },- "pins": [- {- "number": "1",- "name": "SCL",- "type": "input",- "description": "SMBus serial clock (datasheet Rev 021 p.6 Table 2). The 5.7 V zener (Vz) is on 5 V Axx versions only."- },- {- "number": "2",- "name": "SDA/PWM",- "type": "bidirectional",- "description": "SMBus serial data / PWM output (p.6 Table 2)."- },- {- "number": "3",- "name": "VDD",- "type": "power_in",- "description": "External supply, 2.6 to 3.6 V for the B version (p.6 Table 2, p.9 Table 6)."- },- {- "number": "4",- "name": "VSS",- "type": "power_in",- "description": "Negative supply (ground) (p.6 Table 2)."- }- ],- "lcsc_note": "2026-10-21: adom-parts-search found no JLCPCB/LCSC listing for MLX90614ESF-BCI-000-TU.",- "manufacturer_links": {- "product": "https://www.melexis.com/en/product/MLX90614/Digital-Plug-Play-Infrared-Thermometer-TO-Can",- "datasheet": "https://www.melexis.com/-/media/files/documents/datasheets/mlx90614-datasheet-melexis.pdf"- }+ "parts": {+ "symbol": "mlx90614esf-bci-000-tu.kicad_sym",+ "footprint": "mlx90614esf-bci-000-tu.kicad_mod",+ "model_3d": "mlx90614esf-bci-000-tu-hero.glb",+ "model_3d_plain": "mlx90614esf-bci-000-tu-etched.glb",+ "model_3d_step": "mlx90614esf-bci-000-tu-etched.step",+ "model_3d_step_plain": "mlx90614esf-bci-000-tu.step",+ "step": "mlx90614esf-bci-000-tu-etched.step",+ "lbr": "mlx90614esf-bci-000-tu.lbr",+ "datasheet": "docs/mlx90614esf-bci-000-tu-datasheet.pdf" },- "tags": [- "component",- "sensor",- "temperature-sensor",- "infrared",- "thermopile",- "tht",- "to-39"- ],- "discovery_triggers": [- "MLX90614ESF-BCI-000-TU",- "MLX90614ESF-BCI",- "MLX90614 BCI",- "MLX90614",- "IR thermometer 5 degree FOV",- "TO-39 IR temperature sensor"- ],- "license": "CC-BY-4.0",- "visibility": {- "public": true+ "viewers": {+ "symbol": "viewers/symbol.html",+ "footprint": "viewers/footprint.html"+ },+ "viewer_3d": {+ "ground": false,+ "animate": false,+ "shadows": false,+ "tooltips": "authored" },- "author": {- "name": "John Lauer",- "email": "[email protected]"+ "models": "models.json",+ "lod": "lod/manifest.json",+ "verification": "verification.json",+ "marking": {+ "lines": [+ "BCI"+ ],+ "source": "Melexis MLX90614 datasheet Rev 021 p.50 Table 20 (laser marking: 3-letter device code BCI followed by a 7-digit lot number)",+ "surface": "side wall (+Y), position not given by the datasheet",+ "colour": "dark laser mark on nickel can",+ "note": "lot digits omitted: they differ per lot"+ },+ "pins": [+ {+ "number": "1",+ "name": "SCL",+ "type": "input",+ "description": "SMBus serial clock (datasheet Rev 021 p.6 Table 2). The 5.7 V zener (Vz) is on 5 V Axx versions only."+ },+ {+ "number": "2",+ "name": "SDA/PWM",+ "type": "bidirectional",+ "description": "SMBus serial data / PWM output (p.6 Table 2)."+ },+ {+ "number": "3",+ "name": "VDD",+ "type": "power_in",+ "description": "External supply, 2.6 to 3.6 V for the B version (p.6 Table 2, p.9 Table 6)."+ },+ {+ "number": "4",+ "name": "VSS",+ "type": "power_in",+ "description": "Negative supply (ground) (p.6 Table 2)."+ }+ ],+ "distributor_links": {+ "mouser": {+ "part": "482-90614ESFBCI000TU",+ "url": "https://www.mouser.com/en/ProductDetail/Melexis/MLX90614ESF-BCI-000-TU?qs=KuGPmAKtFKXB55OHcItFHA%3D%3D",+ "stock": 859,+ "checked": "2026-10-21"+ },+ "digikey": {+ "part": "MLX90614ESF-BCI-000-TU-ND",+ "url": "https://www.digikey.com/en/products/detail/melexis-technologies-nv/MLX90614ESF-BCI-000-TU/2666249",+ "stock": 1426,+ "checked": "2026-10-21"+ },+ "lcsc": false },- "sample_prompts": [],- "discovery_pitch": null,- "metadata": {},- "created_at": "2026-10-21T16:52:21.037Z",- "updated_at": "2026-10-21T16:52:21.037Z",- "org": "adom"+ "lcsc_note": "2026-10-21: adom-parts-search found no JLCPCB/LCSC listing for MLX90614ESF-BCI-000-TU.",+ "manufacturer_links": {+ "product": "https://www.melexis.com/en/product/MLX90614/Digital-Plug-Play-Infrared-Thermometer-TO-Can",+ "datasheet": "https://www.melexis.com/-/media/files/documents/datasheets/mlx90614-datasheet-melexis.pdf"+ }+ },+ "dependencies": {},+ "hero": {+ "type": "image",+ "path": "docs/hero.png"+ },+ "visibility": {+ "public": true+ },+ "discovery_triggers": [+ "MLX90614ESF-BCI-000-TU",+ "MLX90614ESF-BCI",+ "MLX90614 BCI",+ "MLX90614",+ "IR thermometer 5 degree FOV",+ "TO-39 IR temperature sensor"+ ] }